Mounting the Thermostat

1.

Using the PTF14A Socket or PTF14A-E Socket with Finger 
Protection, mount the Thermostat to the bracket that is provided.

2.

The structure does not allow the case to be removed. Do not apply 
excessive force when mounting the Thermostat.

Settings

1.

E5L-A

@

 Temperature Dial

The temperature dial has some backlash. To adjust the 
temperature more accurately, turn the dial clockwise when 
adjusting the temperature.

Do not change the setting of the temperature dial more than 20 
times.

Do not attempt to turn the dial past the range of the setting scale. 
Applying excessive force may damage the Thermostat.

2.

E5L-A

@

 Hysteresis Dial

This dial can be used to set hysteresis for the ON/OFF operation. 
Turn the dial clockwise to reduce the hysteresis and 
counterclockwise to increase the hysteresis. Increase the 
hysteresis to extend the life of the relay by preventing relay 
chattering caused by the control output turning ON and OFF 
frequently.

Do not change the setting of the temperature dial more than 20 
times.

Mounting the Thermistor

Select a location for the temperature sensor of the thermistor 
where the temperature distribution of sensing objects will not be 
changed by installation.

Insert the temperature sensor as far in as possible.

When measuring fluid temperature, the thermistor should be 
installed against the current. Before mounting, take factors such as 
the bending moment of inertia and vibration into consideration.

Do not apply mechanical force to the temperature-sensing part of 
the thermistor.

The E52-THE

@@

 Thermistor can be used for applications that 

require metal protective tubing. Consult with your OMRON 
representative.

Other Precautions

Do not use the E5L-C

@

 if the front sheet is peeling or torn.

Use appropriate tools to disassemble the Thermostat for disposal.

Precautions for Correct Use

(98.6)

(4.6)

(4.6)

(98.6)

E5L+PTF14A

E5L+PTF14A-E

Summary of Contents for E5L-C Series

Page 1: ...ic Thermostats E5L A E5L C Note The E5L C is not available with a set temperature range of 0 to 50 C Options Order Separately Sockets 1 2 E5L 1 Setting and Indication Methods A Analog setting no display C Digital setting display 2 Set temperature 30 20 30 to 20 C 0 50 0 to 50 C 0 100 0 to 100 C 100 200 100 to 200 C Size Type Control method Control output Model 45 35 mm Plug in ON OFF operation Rel...

Page 2: ... 100 to 200 C models 10 C Influence of temperature 1 of PV or 2 C whichever is greater 1 digit max Influence of voltage Sampling period 2 s Insulation resistance 100 MΩ max at 500 VDC Dielectric strength 2 300 VAC 50 60 Hz for 1 min between charged terminals and uncharged metallic parts between power supply terminals and input terminals between power supply terminals and output terminals and betwe...

Page 3: ...power supply 100 to 240 VAC Element interchangeable Thermistor 250 VAC 10 A Control output Input power supply 100 to 240 VAC Element interchangeable Thermistor Hysteresis adjuster DIFF Operation indicator Temperature dial Operation Indicator Operation indicator Output status Heating load Cooling load Lit red ON OFF Not lit OFF ON E5L A Mode Key Down Key Up Key Operation indicator Set value indicat...

Page 4: ... 100 to 200 C Models Mounting Brackets Two 30 max 45 5 max 78 5 max Two 4 5 x 6 mounting holes 8 35 4 3 4 7 0 2 14 M3 5 x 8 Sems screws 7 0 2 33 max 45 5 max 78 5 max Two 4 5 x 6 mounting holes 14 M3 5 x 8 Sems screws 8 35 5 3 4 PTF14A PTF14A E Socket with Finger Protection 8 11 10 9 12 13 14 7 6 5 4 3 2 1 TOP VIEW 68 0 3 36 0 2 Two M4 or 4 5 dia holes TOP VIEW Note Can be mounted to a DIN Track C...

Page 5: ...made Setting Direct or Reverse Operation 1 Press the Key for at least 3 s to enter the Direct Reverse Selection Mode 2 Press the and Keys to set the value Direct operation can be set by pressing the Key and reverse operation can be set by pressing the Key Note 1 The default setting is for reverse operation 2 The control output turns OFF while this setting is being made Process value Power ON Set t...

Page 6: ...settings are being changed except for memory errors The control output status will be as shown in the above table while the set temperature or hysteresis is being set The control output will be OFF while the temperature input shift or direct reverse operation setting is being set Key operations will be possible when an error occurs except for a memory error 2 The setting protection indicator and s...

Page 7: ... locations Locations directly subject to heat radiated from heating equipment Locations subject to water or oil Locations subject to direct sunlight Locations subject to dust or corrosive gas in particular sulfide gas and ammonia gas Locations subject to sudden or extreme temperature changes Locations subject to icing or condensation Locations subject to vibration or shock 2 Use and store the Prod...

Page 8: ...is to extend the life of the relay by preventing relay chattering caused by the control output turning ON and OFF frequently Do not change the setting of the temperature dial more than 20 times Mounting the Thermistor Select a location for the temperature sensor of the thermistor where the temperature distribution of sensing objects will not be changed by installation Insert the temperature sensor...

Page 9: ...9 MEMO ...

Page 10: ...MEMO 10 ...

Page 11: ...D INSTALLED AND MAINTAINED AND NOT SUBJECT TO CONTAMINATION ABUSE MISUSE OR INAPPROPRIATE MODIFICATION OR REPAIR Application Considerations SUITABILITY FOR USE OMRON shall not be responsible for conformity with any standards codes or regulations that apply to the combination of products in the customer s application or use of the products Take all necessary steps to determine the suitability of th...

Page 12: ...mburg IL 60173 5302 U S A Tel 1 847 843 7900 Fax 1 847 843 7787 OMRON ASIA PACIFIC PTE LTD No 438A Alexandra Road 05 05 08 Lobby 2 Alexandra Technopark Singapore 119967 Tel 65 6835 3011 Fax 65 6835 2711 OMRON CHINA CO LTD Room 2211 Bank of China Tower 200 Yin Cheng Zhong Road PuDong New Area Shanghai 200120 China Tel 86 21 5037 2222 Fax 86 21 5037 2200 Control Devices Division H Q Analog Controlle...

Reviews: