E5L

2

Ratings and Characteristics

Ratings

Note:

Do not use the output from an Inverter as the power supply.

Characteristics

*

The accuracy of the accessory thermistor is not included.

Item

Model

E5L-A

@

E5L-C

@

Power supply voltage

100 to 240 VAC, 50/60 Hz

Operating voltage range

85% to 110% of the rated supply voltage

Power consumption

Approx. 3 VA

Inputs

Element-interchangeable thermistor

Control method

ON/OFF control

Control output

SPDT contacts, 250 VAC, 10 A, cos

φ

 = 1 (resistive load) SPST-NO contacts, 250 VAC, 10 A, cos

φ

 = 1 (resistive load)

Setting method

Analog setting

Digital settings using keys on front panel

Indication method

No display

LCD digital display (character height: 12 mm)

Other functions

Setting protection (key protection)

Input shift

Direct/reverse operation

Ambient temperature

10 to 55

°

C (with no icing or condensation)

Ambient humidity

25% to 85%

Storage temperature

25

°

C to 65

°

C (with no icing or condensation)

Item

Model

E5L-A

@

E5L-C

@

Indication accuracy

---

±

(1

°

C + 1 digit) max.

*

Setting accuracy

---

±

(1

°

C + 1 digit) max.

*

Hysteresis

30 to 20

°

C models: Approx. 0.5 to 2.5

°

C (variable)

0 to 50

°

C models: Approx. 0.5 to 4

°

C (variable)

0 to 100

°

C models: Approx. 0.5 to 4

°

C (variable)

100 to 200

°

C models: Approx. 0.7 to 4

°

C (variable)

1 to 9

°

C (in increments of 1

°

C)

Repeat accuracy

1% FS max.

---

Minimum scale 
(standard scale)

30 to 20

°

C models and 0 to 50

°

C models: 5

°

C

0 to 100

°

C models and 100 to 200

°

C models: 10

°

C

---

Influence of temperature 

---

±

((1% of PV or 2

°

C, whichever is greater) +1 digit) max.

Influence of voltage

---

Sampling period

---

2 s

Insulation resistance

100 M

 max. (at 500 VDC)

Dielectric strength

2,300 VAC, 50/60 Hz for 1 min (between charged terminals and uncharged metallic parts, between power supply 
terminals and input terminals, between power supply terminals and output terminals, and between input terminals 
and output terminals)

Vibration (malfunction)

Frequency of 10 to 55 Hz, 0.5-mm double amplitude for 10 min each in X, Y, and Z directions

Vibration (destruction)

Frequency of 10 to 55-Hz, 0.75-mm double amplitude for 2 h each in X, Y, and Z directions

Shock (malfunction)

147 m/s

2

, 3 times each in 6 directions

100 m/s

2

, 3 times each in 6 directions

Shock (destruction)

294 m/s

2

, 3 times each in 6 directions

Electrical life expectancy 
(control output relay)

100,000 operations min (at maximum applicable load)

Memory protection

---

Non-volatile memory (100,000 write operations)

Weight (Thermostat)

Approx. 80 g (Thermostat only)

Degree of protection

Front panel: IP40, Terminals: IP00

Approved standards

---

Conformed standards

EN 61010-1 (IEC 61010-1), Pollution Degree 2, Overvoltage Category II

EMC Directives

EMI:

EN61326-1

Radiated EMI:

EN55011 Group1 ClassA

Conducted EMI:

EN55011 Group1 ClassA

EMS:

EN61326-1

Electrostatic discharge immunity: 

EN61000-4-2

Electromagnetic field strength immunity: 

EN61000-4-3

Burst noise immunity: 

EN61000-4-4

Conducted disturbance immunity: EN61000-4-6
Surge immunity: 

EN61000-4-5

Voltage dip and power interruption immunity:  EN6100-4-11

Summary of Contents for E5L-C Series

Page 1: ...ic Thermostats E5L A E5L C Note The E5L C is not available with a set temperature range of 0 to 50 C Options Order Separately Sockets 1 2 E5L 1 Setting and Indication Methods A Analog setting no display C Digital setting display 2 Set temperature 30 20 30 to 20 C 0 50 0 to 50 C 0 100 0 to 100 C 100 200 100 to 200 C Size Type Control method Control output Model 45 35 mm Plug in ON OFF operation Rel...

Page 2: ... 100 to 200 C models 10 C Influence of temperature 1 of PV or 2 C whichever is greater 1 digit max Influence of voltage Sampling period 2 s Insulation resistance 100 MΩ max at 500 VDC Dielectric strength 2 300 VAC 50 60 Hz for 1 min between charged terminals and uncharged metallic parts between power supply terminals and input terminals between power supply terminals and output terminals and betwe...

Page 3: ...power supply 100 to 240 VAC Element interchangeable Thermistor 250 VAC 10 A Control output Input power supply 100 to 240 VAC Element interchangeable Thermistor Hysteresis adjuster DIFF Operation indicator Temperature dial Operation Indicator Operation indicator Output status Heating load Cooling load Lit red ON OFF Not lit OFF ON E5L A Mode Key Down Key Up Key Operation indicator Set value indicat...

Page 4: ... 100 to 200 C Models Mounting Brackets Two 30 max 45 5 max 78 5 max Two 4 5 x 6 mounting holes 8 35 4 3 4 7 0 2 14 M3 5 x 8 Sems screws 7 0 2 33 max 45 5 max 78 5 max Two 4 5 x 6 mounting holes 14 M3 5 x 8 Sems screws 8 35 5 3 4 PTF14A PTF14A E Socket with Finger Protection 8 11 10 9 12 13 14 7 6 5 4 3 2 1 TOP VIEW 68 0 3 36 0 2 Two M4 or 4 5 dia holes TOP VIEW Note Can be mounted to a DIN Track C...

Page 5: ...made Setting Direct or Reverse Operation 1 Press the Key for at least 3 s to enter the Direct Reverse Selection Mode 2 Press the and Keys to set the value Direct operation can be set by pressing the Key and reverse operation can be set by pressing the Key Note 1 The default setting is for reverse operation 2 The control output turns OFF while this setting is being made Process value Power ON Set t...

Page 6: ...settings are being changed except for memory errors The control output status will be as shown in the above table while the set temperature or hysteresis is being set The control output will be OFF while the temperature input shift or direct reverse operation setting is being set Key operations will be possible when an error occurs except for a memory error 2 The setting protection indicator and s...

Page 7: ... locations Locations directly subject to heat radiated from heating equipment Locations subject to water or oil Locations subject to direct sunlight Locations subject to dust or corrosive gas in particular sulfide gas and ammonia gas Locations subject to sudden or extreme temperature changes Locations subject to icing or condensation Locations subject to vibration or shock 2 Use and store the Prod...

Page 8: ...is to extend the life of the relay by preventing relay chattering caused by the control output turning ON and OFF frequently Do not change the setting of the temperature dial more than 20 times Mounting the Thermistor Select a location for the temperature sensor of the thermistor where the temperature distribution of sensing objects will not be changed by installation Insert the temperature sensor...

Page 9: ...9 MEMO ...

Page 10: ...MEMO 10 ...

Page 11: ...D INSTALLED AND MAINTAINED AND NOT SUBJECT TO CONTAMINATION ABUSE MISUSE OR INAPPROPRIATE MODIFICATION OR REPAIR Application Considerations SUITABILITY FOR USE OMRON shall not be responsible for conformity with any standards codes or regulations that apply to the combination of products in the customer s application or use of the products Take all necessary steps to determine the suitability of th...

Page 12: ...mburg IL 60173 5302 U S A Tel 1 847 843 7900 Fax 1 847 843 7787 OMRON ASIA PACIFIC PTE LTD No 438A Alexandra Road 05 05 08 Lobby 2 Alexandra Technopark Singapore 119967 Tel 65 6835 3011 Fax 65 6835 2711 OMRON CHINA CO LTD Room 2211 Bank of China Tower 200 Yin Cheng Zhong Road PuDong New Area Shanghai 200120 China Tel 86 21 5037 2222 Fax 86 21 5037 2200 Control Devices Division H Q Analog Controlle...

Reviews: