background image

 

Digital Position-Proportional Controllers

 

E5EZ-PRR

29

Digital Position-Proportional Controllers

E5EZ-PRR

A position proportional control model for the E5

@

Z-PRR series

• Just 78mm depth

• All types of input: temperature input type, analog (current, voltage) input 

type

• Makes use of high-visibility LCD, with three lines of 4-digit display, for 

simplicity and clarity

• 3 lines of display to observe PV/ SV/ MV (percentage of valve's opening), 

clearly displaying the state of control (operations)

• Event input enables the selection of multi configurations as well as a 

start/ stop function

• Alarm delay function

• Communications function

• Able to choose floating control or closed control. In floating control, 

position proportional control can be realized without a potentiometer

• Equipped with a manual output function (equipped with an automatic/ 

manual key)

Model

 

Number

 

Structure

Model Number Legend

Ordering Information

Accessories

 

(Order

 

Separately)

Unit Label

Size

Power

 

Supply

Voltage

Input

 

Type

Control
Method

Number of

alarm

 

points

Communication

Function

Event

 

Input

Model

1/8DIN

48

×

96

×

78

(W

×

H

×

D)

100 to 240 VAC

Temperature

Input Type

Valve Control

2

None

None

E5EZ-PRR2T

2 points

E5EZ-PRR2BT

RS-232C

None

E5EZ-PRR201T

RS-485

E5EZ-PRR203T

Analog

(Current, Voltage)

Input Type

None

None

E5EZ-PRR2L

2 points

E5EZ-PRR2BL

RS-232C

None

E5EZ-PRR201L

RS-485

E5EZ-PRR203L

Model

Y92S-L1

Refer to the "Safety Precautions" on page 52. 

1   2   3   4   5     6

1. Control method

    P:  Valve control  

2. 

Control output 1

R:  Relay (OPEN)

3. Control output 2

R: Relay (CLOSE)

4. Alarm output

2: 2 alarm outputs

5. Option

Blanks: Not 

available

01: RS-232C
03: RS-485
B: 

2 event inputs

6.  Input Type

T: Temperature 
L: Analog input (current, voltage)

Summary of Contents for E5EZ-PRR Series

Page 1: ...thout a potentiometer Equipped with a manual output function equipped with an automatic manual key Model Number Structure Model Number Legend Ordering Information Accessories Order Separately Unit Label Size Power Supply Voltage Input Type Control Method Number of alarm points Communication Function Event Input Model 1 8DIN 48 96 78 W H D 100 to 240 VAC Temperature Input Type Valve Control 2 None ...

Page 2: ...2C Communications Baud Rate 1200 2400 4800 9600 19200bps RS 485 Communications Baud Rate 1200 2400 4800 9600 19200bps Event Input ON Maximum of 1KΩ OFF Minimum of 100KΩ Setting number K T J E L U N R S B 10 to 70 C 60 to 120 C 115 to 165 C 140 to 260 C 1800 1700 1600 1500 1400 1300 1200 1100 1000 900 800 700 600 500 400 300 200 100 0 100 200 21 0 to 50mV 17 70 10 18 120 60 6 20 0 500 0 5 200 1300 ...

Page 3: ... Event input Contact input ON 1kΩ max OFF 100 kΩ min Non contact input ON Residual voltage 1 5 V max OFF Leakage current 0 1 mA max Outflow current Approx 7 mA per point Control method 2 PID control Setting method Digital setting using front panel keys Indication method 7 segment digital display and individual indicators Character height PV 9mm SV 7mm MV 6 8mm Other functions According to controll...

Page 4: ...nputs 1 of PV or 2 C whichever is greater 1 digit max Analog inputs 1 of FS 1 digit max Influence of voltage See note 2 Proportional band P 0 1 to 999 9 C unit 0 1 EU Integral time I 0 to 3999 s in units of 1s With floating control 1 to 3999 s Derivative time D 0 to 3999 s in units of 1s Control period 1 to 99 s in units of 1s Manual reset value 10 0 to 110 0 in units of 0 1 Alarm settings range 1...

Page 5: ...nit mm Simultaneous Multiple Installations Unit mm 48 Number of Units 2 5 45 92 92 above 120 During installation please insert a temperature gauge into the grooves on the panel thickness of 1 to 8 mm and insert the metallic components for installation into the fixing hooks at the bottom and the top of the rear cover Please ensure that the screws to metallic components are even and locked When doin...

Page 6: ...For E5EZ PRR 03 model products in order to satisfy the conduction and emission specifications of EN61326CLASSA a mag netic ring TDK ZAT1730 0730 should be added to the communications line between the K3SC unit and the controller E5EZ PRR Alarm Output 1 Alarm Output 2 B B A mA DO NOT USE USE DO NOT 50 60Hz Potentiometer Communications Communications OPEN 10 Pt 11 6 8 7 9 100 to 240 VAC 1 2 3 4 5 12...

Page 7: ...ted in any other cases Displays the process value or the designated data type Fully illuminated for approximately one second upon start up Displays setting values reading values and input values Fully illuminated for approximately one second upon start up When valve opening display is on it displays the percentage of the valve s opening No display when valve opening display is switched off Every t...

Page 8: ...5 c 0 M alt1 2 in t 5 M al 1 c 20 20 100 25 c 100 M M M r 5 run Setup Steps Initial setting level Operation level Connect the power supply Connect the power supply Set the input type Set the alarm type Set the alarm value Begin operations Begin operations Alarm value1 While running Process value set value percentage of valve opening While stopped stop Check alarm type Check input type 5 Input type...

Page 9: ... While stopped stop 150 9 Input type Alarm1 2 Type Control stops L Control starts L L Execute AT Cancel AT l ini l ini Process value set value percentage of valve opening run ON OFF l adj l adj l adj 100 0 100 0 100 0 100 0 100 0 Input type 9T thermocouple 200 C to 400 C Control method PID control Execute AT auto tuning to calculate the PID constant Alarm 1 type Upper limit of 2 Set value 150 C Pr...

Page 10: ...ntrol stops Protect level Operation level Adjustment level Manual control level Initial setting level Advanced function setting level Communications setting level Third Display Level s Name Manual MV Manual control level l prt Protect level No display Operation level l adj Adjustment level l ini Initial setting level l com Communications setting level l adv Advanced function setting level L L key ...

Page 11: ...In manual control with process value set value percentage of valve opening manual MV displayed pressing the A key for at least 1 second will move you into auto matic mode and switch you to the operation level displaying op eration level s initial data In this mode it is possible to perform MV manual operations Initial Setting Level To switch to this level it is necessary to press the key in op era...

Page 12: ... 200 to 1300 C 300 to 2300 F 6 20 0 to 500 0 C 0 0 to 900 0 F J 7 100 to 850 C 100 to 1500 F 8 20 0 to 400 0 C 0 0 to 750 0 F T 9 200 to 400 C 300 to 700 F 22 199 9 to 500 0 C 199 9 to 700 0 F E 10 0 to 600 C 0 to 1100 F L 11 100 to 850 C 100 to 1500 F U 12 200 to 400 C 300 to 700 F 23 199 9 to 500 0 C 199 9 to 700 F N 13 200 to 1300 C 300 to 2300 F R 14 0 to 1700 C 0 to 3000 F S 15 0 to 1700 C 0 ...

Page 13: ...F 0 X ON OFF 0 X ON OFF 0 SP ON OFF X L H SP SP L H L SP H H LSP SP H L H 0 L 0 H L H 0 L 0 H L Case 1 Case 2 Case 3 Always ON H 0 L 0 H L H 0 L 0 H L H 0 L 0 L H SP SP L H L SP H H L SP SP H L 3 Set value 4 Upper and lower limit range 2 Set value 1 Upper and lower limit Case 1 Case 2 Case 3 Always OFF 4 Set value 5 Upper and lower limit with standby sequence for the upper and lower alarm limits a...

Page 14: ...el See note 1 See note 2 Control stops See note 2 25 100 c 100 0 25 100 c 100 0 a m c Press L key for at least 1 s Press the L key for at least 1 s display will flash Press the L key for at least 3 s Press the L key for at least 3 s while Press L key for at least 1 s a m is displayed Press the L key for at least 1 s display will flash Press the L key for at least 1 s Press L key for at least 1 s N...

Page 15: ...al MV Limits in effect l ini l ini l ini d u c sl h 1300 sl l 200 SP upper limit SP lower limit Direct reverse operation Direct operation on d Reverse operation or r Alarm 1 alt2 2 Alarm 2 Closed floating Floating flot Closed clos Electro mechanical calibration Electro mechanical calibration on Cancel off alt1 2 clfl flot calb off Travel time mot 30 l ini l ini l ini l ini l ini l ini l ini l ini ...

Page 16: ... time Unit seconds d 40 i 233 al1h 0 al1l 0 Upper limit alarm value 1 Lower limit alarm value 1 al 2 0 al2h 0 al2l 0 Alarm value 2 Upper limit alarm value 2 Lower limit alarm value 2 Process value Multi SP set point setting SP ramp set point 25 m sp 0 sp m 0 Run stop Run run Stop stop Alarm value 1 Set either of these parameters Set either these parameters SP used by Multi SP MV limit value 1 poin...

Page 17: ...le communication unit number set for it Mode Set Values Can be displayed changed Can be displayed Cannot be displayed no changes in level allowed 0 1 2 3 Present value Set value Others Adjustment level Set Value Initial setting level Communications 0 Able to switch able to switch to the advanced functions setting level Able to switch 1 Able to switch unable to switch to the advanced functions sett...

Page 18: ...gy flow was affecting the control system Check for any such noise Operations with Errors The control output will be determined according to the designated value for error MV The alarm output function will be the same as it is when the upper limit is crossed After setting I O error advanced function setting level on alarm 1 s output will be activated in cases of error In process value or process va...

Page 19: ... change the E5EZ PRR If the display the root of the problem may have been interference which should be avoided in the future The control output will be determined according to the designated value for error MV Alarm output will operate as normal Meaning Rectification Measures Operations with Errors Electro mechanical calibration was not properly completed After confirming the potentiometer and the...

Page 20: ...n furnace valves position propor tional control should be applied See the following figure for measurement devices The SP ramp function allows limits to be placed on temperature changes which control the temperature within a specific range This is useful for ceramic furnace in which severe temperature changes may cause dam age or corruption Set Value SP Ramp RUN SP ramp as time unit SP ramp s set ...

Page 21: ...me and SP ramp values are set Initial values are used for all others 1 Press the key for at least 3 seconds to switch from the operation level to the initial setting level 2 Press the M key multiple times and select mot travel time Press the U key making the set value 45 3 Press the key for at least 1 second returning to the operation level The process value set value percentage of valve opening w...

Page 22: ...closed is also set for self measuring In cases of floating control where a potentiometer is not connected it will be nec essary to manually set the travel time Set the time required for the valve to go from complete openness to complete closure under travel time Position Proportion Dead Band Switch and Position Proportional Hysteresis The valve output period the time it takes the OPEN output and C...

Reviews: