background image

Analogue Temperature Controller

 

E5C2

I-9

Tem

p

erature

Co

ntro

ller

Nomenclature

Operation Indicator

Dimensions

Note:

All units are in millimeters unless otherwise indicated.

Temperature setting knob

Operation indicator

RESET adjustment shaft 
No reset function is incorporated by any 
E5C2 model with ON/OFF control.

Indicator

Output

Red

Lit

ON

Not lit

OFF

93

+1
 0

141

+1
 0

189

+1
 0

237

+1
 0

285

+1
 0

N

2

3

4

5

6

L

48 x 48

44.8 x 44.8

Panel Cutout

Note: 1. 

Recommended panel thickness is 1 to 4 mm.

2.

 Close side-by-side mounting is possible (in a single direction).

Panel

Y92F-30 Flush-mounting adapter

Tightening screw

(96) (see note)

Note: 

109 mm for US08 Back Connecting Socket

Terminal Arrangement 
(Bottom View)

Dimensions with Flush-mounting Adapter (Accessory), 
and Back Connecting Socket (Sold Separately)

Flush-mounting 
adapter

P3G-08 Back con-
necting socket

Side-by-side Mounting 
of N Controllers

60 min.

Summary of Contents for E5C2

Page 1: ...ter PT100 G Thermistor THE 5 Special type Blank Standard type D DIN Special types Ordering Information Temperature Controllers Note When placing an order specify the standard temperature range and supply voltage in addition to the model number e g E5C2 R20K 0 C to 200 C 100 110 VAC Accessories Order Separately 1 2 3 4 5 E5C2 Setting method Indication method Control mode Output Model Thermocouple P...

Page 2: ...to 1 200 25 0 to 200 5 0 to 300 10 0 to 400 10 50 to 50 2 20 to 80 2 0 to 50 1 0 to 100 2 0 to 200 5 0 to 300 10 0 to 400 10 50 to 50 2 6 kΩ at 0 C 0 to 100 2 6 kΩ at 0 C 50 to 150 2 30 kΩ at 0 C F 32 to 392 10 32 to 572 20 32 to 752 20 32 to 1 112 40 32 to 1 472 50 32 to 1 832 50 32 to 2 192 50 32 to 392 10 32 to 572 20 32 to 752 20 32 to 212 5 32 to 392 10 Setting accuracy 2 FS max Hysteresis Ap...

Page 3: ... lit OFF 93 1 0 141 1 0 189 1 0 237 1 0 285 1 0 N 2 3 4 5 6 L 48 x 48 44 8 x 44 8 Panel Cutout Note 1 Recommended panel thickness is 1 to 4 mm 2 Close side by side mounting is possible in a single direction Panel Y92F 30 Flush mounting adapter Tightening screw 96 see note Note 109 mm for US08 Back Connecting Socket Terminal Arrangement Bottom View Dimensions with Flush mounting Adapter Accessory a...

Page 4: ...portional operation add an appropriate external relay to the E5C2 by considering the capacity of the load and the life of the relay Power Supply If a single power supply is used for the E5C2 and the load the supply voltage of the power supply may vary greatly when the load is open or closed if the capacity of the power supply is not large enough Make sure that the capacity of the power supply is l...

Page 5: ... 08 can be wired in the same way as the P2CF 08 Dismounting If flush mounted loosen the screw of the adapter and disengage the hooks for dismounting Temperature Setting Do not turn the temperature setting knob of the E5C2 with excessive force otherwise the stopper of the knob may break Others Do not remove the housing of the E5C2 otherwise the housing may break To clean the surface of the E5C2 use...

Page 6: ...he interest of product improvement specifications are subject to change without notice ALL DIMENSIONS SHOWN ARE IN MILLIMETERS To convert millimeters into inches multiply by 0 03937 To convert grams into ounces multiply by 0 03527 Cat No H081 E1 02 ...

Reviews: