- 17 -
* Value one hour after the product is turned on. Note, however, that external disturbance sometimes causes minute output.
8. Ratings
Ratings and Specifications
Type
Twin output model
Analog output model
Model
E4C-UDA11
E4C-UDA41
E4C-UDA11AN
E4C-UDA41AN
NPNoutput
PNPoutput
NPNoutput
PNPoutput
Connection method
Prewired
Supply voltage
12 to 24 VDC ± 10%, ripple 10% max.
Current consumption
80 mA max.
Control output
NPN open collector (26.4 VDC max.)
Load current: 50 mA max., Residual voltage: 1 V max.
Hysteresis
2.0% F.S.max.
Timer
OFF/OFF-delay/ON-delay/one-shot
Timer time
1 ms to 5 s
Analog
output
Output form
-
Voltage output (DC 1 to 5 V)
Connected load
-
10 k
Ω
min.
Temperature
characteristics
-
0.3% F.S./
°
C
Resolution
-
2.0% F.S.max. *
Linearity
-
2.0% F.S.max.
Operating temperature
Operating: -25 to +55°C Storage: -30 to +70°C (with no icing)
Operating humidity
Operating and storage: 35% to 85% (with no condensation)
Insulation resistance
50 M
Ω
min. (by 500 VDC)
Dialectic strength
1,000 VAC, 50/60 Hz for 1 min
Vibration resistance
10 to 150 Hz, 0.75 mm double amplitude, 80 min each in X, Y, and Z directions
Shock resistance
500 mm/s
2
, 3 times each in X, Y and Z directions
Materials
Case: PBT (polybutylene terephthalate), Cover: Polycarbonate
Weight
Approx. 150 g
Accessories
Instruction Manual
I/O Circuit Diagrams
J
E4C-UDA11 (NPN type)
J
E4C-UDA41 (PNP type)
J
E4C-UDA11AN (NPN type)
J
E4C-UDA41AN (PNP type)
DC
12 to 24 V
Brown
Black 1CH output
Orange 2CH output
Blue
Internal circuit
Load
Load
DC
12 to 24 V
Brown
Black 1CH output
Orange 2CH output
Blue
Internal circuit
Load
Load
Brown
Blue
10 KW min.
DC
12 to 24 V
Black Control output
Orange Analog output
Internal circuit
Load
Load
Brown
Blue
10k
ǡ
MIN
DC
12 to 24 V
Black control output
Orange
Analog
output
Internal circuit
Load
Load
1636705-7A_e4c-uda_E.fm 17 ページ 2005年11月15日 火曜日 午後4時58分