E3ZM-V
Operating Procedure
Two-point Teaching Using Teaching Button
1. Place the point for which you want the output to go ON in the beam spot position.
Then, press and hold the teaching button for at least 2 seconds.
The teaching indicator (red) will begin flashing quickly. (This indicates that the output ON teaching
operation should begin.)
Perform the following operation within 7 seconds of when you start pushing the button. (After 7 seconds,
the Unit will return to its initial condition.)
2. Press the teaching button for approximately 0.5 second.
The teaching indicator (red) will light for approximately 0.5 second to show that the output ON
teaching is completed.
The teaching indicator (red) will then begin flashing quickly again to show that the output OFF teaching
operation should begin.
3. Place the point where you want the output to go OFF in the beam spot position.
4. Press the teaching button for approximately 0.5 second.
The teaching indicator (red) will light for approximately 0.5 second to show that the output OFF
teaching is completed.
When Teaching Is Successful
When Teaching Is Not Successful
The stability indicator (green) shows that detection is stable.
The teaching indicator (red) flashes
slowly.
(Flashes in cycles of approx.
6 seconds.)
1.Lights
→
This indicates stable detection,
even if there is some fluttering
in the sensing object.
2.Flashes
→
This indicates the possibility of
unstable detection, due to
fluttering in the sensing object.
3.Remains OFF
→
This indicates unstable
detection.
Repeat the operation starting with step 1.
The Sensor enters normal operating condition.
S
en
s
or
B
a
ckgro
u
nd
M
a
rk
Fl
as
he
s
qu
ickly
Lit for
a
pproxim
a
tely
0.5
s
econd
Fl
as
he
s
qu
ickly
S
en
s
or
B
a
ckgro
u
nd
M
a
rk
Lit for
a
pproxim
a
tely
0.5
s
econd
Fl
as
he
s
s
lowly
Fl
as
he
s
Off
Lit
Stable detection
Unstable detection
ON point
OFF point
Lit Lit
Off Lit
Lit Off
Off
Off