Photoelectric Sensor

Do not use the Sensor in any atmosphere or environment that 
exceeds the ratings.

Do not install the Sensor in the following locations.

(1)Locations subject to direct sunlight
(2)Locations subject to condensation due to high humidity
(3)Locations subject to corrosive gas
(4)Locations where the Sensor may receive direct vibration or 

shock

Connecting and Mounting

(1)The maximum power supply voltage is 30 VDC. Before 

turning the power ON, make sure that the power supply 
voltage does not exceed the maximum voltage.

(2)Laying Sensor wiring in the same conduit or duct as high-

voltage wires or power lines may result in malfunction or 
damage due to induction. As a general rule, wire the Sen-
sor in a separate conduit or use shielded cable.

(3)Use an extension cable with a minimum thickness of 

0.3 mm

2

 and less than 50 m long.

(4)Do not pull on the cable with excessive force.
(5)Pounding the Photoelectric Sensor with a hammer or other 

tool during mounting will impair water resistance. Also, use 
M3 screws.

(6)Mount the Sensor either using the bracket (sold separately) 

or on a flat surface.

(7)Be sure to turn OFF the power supply before inserting or 

removing the connector.

Power Supply

If a commercial switching regulator is used, ground the FG 
(frame ground) terminal.

Power Supply Reset Time

The Sensor will be able to detect objects 100 ms after the 
power supply is tuned ON. Start using the Sensor 100 ms or 
more after turning ON the power supply. If the load and the 
Sensor are connected to separate power supplies, be sure to 
turn ON the Sensor first.

Turning OFF the Power Supply

Output pulses may be generated even when the power supply 
is OFF. 
Therefore, it is recommended to first turn OFF the power 
supply for the load or the load line.

Load Short-circuit Protection

This Sensor is equipped with load short-circuit protection, but 
be sure to not short circuit the load. Be sure to not use an out-
put current flow that exceeds the rated current. If a load short 
circuit occurs, the output will turn OFF, so check the wiring 
before turning ON the power supply again. The short-circuit 
protection circuit will be reset. The load shortcircuit protection 
will operate when the current flow reaches 1.8 times the rated 
load current. When using a capacitive load, use an inrush 
current of 1.8 times the rated load current or lower.

Water Resistance

Do not use the Sensor in water, rainfall, or outdoors.

When disposing of the Sensor, treat it as industrial waste.

Mounting Diagram

Resistance to Detergents, Disinfectants, and Chemicals

• The Sensor will maintain sufficient performance in typical 

detergents and disinfectants, but performance may suffer 
in some types of detergents, disinfectants, and chemicals. 
Refer to the following table prior to use.

• The E3ZM has passed detergent and disinfectant resis-

tance testing for the substances listed in the following ta-
ble. Use this table as a guide when considering detergents 
and disinfectants.

Note: The Sensor was immersed in the above chemicals, detergents, and

disinfectants for 240 h at the temperatures given, and then passed
an insulation resistance test at 100 MW min.

Restrictions on Sensing Objects

Do not use this Sensor if the color and pattern of the back-
ground are similar to those of the mark.

Detection of Glossy Objects

Mount the Sensor at an angle of 5° to 15°, as shown in the fol-
lowing diagram. This will improve the mark detection capabil-
ity.

Precautions for Correct Use

Type

Product name

Concen-
tration

Tempera-
ture

Time

Chemicals 

Sodium hydroxide, NaOH

1.5%

70°C

240 h

Potassium hydroxide, KOH

1.5%

70°C

240 h

Phosphoric acid, H

3

PO

4

2.5%

70°C

240 h

Sodium hypochlorite, NaClO 0.3%

25°C

240 h

Hydrogen peroxide, H

2

O

2

6.5%

25°C

240 h

Alkaline 
foaming
cleansers

Topax 66s (Ecolab)

3.0%

70°C

240 h

Acidic foam-
ing cleansers

Topax 56 (Ecolab)

5.0%

70°C

240 h

Disinfectants

Oxonia Active 90 (Ecolab)

1.0%

25°C

240 h

TEK121 
(ABC Compounding)

1.1%

25°C

240 h

U

s

a

 mo

u

nting tor

qu

e of

0.5 N·m m

a

x.

E

3

9-L104

Mo

u

nting Br

a

cket

(

s

old 

s

ep

a

r

a

tely)

S

en

s

ing o

b

ject

s

5

°

 to 15

°

S

en

s

ing o

b

ject

s

5

°

 to 15

°

Summary of Contents for E3ZM-V series

Page 1: ...liable print mark detection in the compact sized E3Z housing For packaging machine makers the E3Z family offers a complete sensor platform with one mounting concept simplifying installation and machine design Space saving design with an SUS316L housing The compact design reduces volume by 90 compared to conventional mark sensors Coaxial optical system The coaxial optical system ensures stable dete...

Page 2: ...rks due to RGB signal processing RGB signal processing The white LED and RGB signal processing ensure the stable detection of differently colored print marks The processing algorithm provides a fast response time of 50 µs Easy setting with 2 point or automatic teaching 2 point Teaching Manual Simply aim the beam spot at the mark portion and background portion and press the teaching button Automati...

Page 3: ...or the detection capability for other color com binations E3ZM V61 2M E3ZM V81 2M Connector M8 4 pins E3ZM V66 E3ZM V86 White light 12 2 mm Size Cable Appearance Cable type Model M8 4 pins Standard Straight 2 m 4 wire XS3F E421 402 A 5 m XS3F E421 405 A L shaped 2 m XS3F E422 402 A 5 m XS3F E422 405 A Appearance Model Material Quantity Remarks Appearance Model Metal material Quantity Remarks E39 L...

Page 4: ...versed power supply polarity Load short circuit protection and Reversed output polarity protection Response time Operate or reset 50 μs max Sensitivity adjustment Teaching method Ambient illumination Receiver side Incandescent lamp 3 000 lx max Sunlight 10 000 lx max Ambient temperature range Operating 40 to 60 C 3 Storage 40 to 70 C with no icing or condensation 3 Do not bend the cable in tempera...

Page 5: ...kground color Yellow red 14 0 13 5 13 0 12 5 12 0 11 5 11 0 10 5 10 0 Black White Red Yellow red Yellow green Green Blue green Blue Detectable range mm Teaching distance 12 mm Background color Yellow 14 0 13 5 13 0 12 5 12 0 11 5 11 0 10 5 10 0 Black White Red Yellow red Yellow Green Blue green Blue Detectable range mm Teaching distance 12 mm Background color Yellow green 14 0 13 5 13 0 12 5 12 0 ...

Page 6: ...FF Operate Reset Sensing object Operation indicator yellow Output transistor Load e g relay Control output Remote control input 1 2 4 3 1 2 4 3 10 to 30 VDC Brown Black Blue Pink Operation indicator yellow Stability indicator green Teaching indicator red M8 Connector Pin Arrangement Photo electric Sensor Main Circuit Load Color taught 2nd Between blue 3 and black 4 leads Color taught 1st Color tau...

Page 7: ...available connector follow the usage and tightening torque instructions provided by the manufacturer Load Do not use a load that exceeds the rated load Low temperature Environments Do not touch the metal surface with your bare hands when the temperature is low Touching the surface may result in a cold burn Oily Environments Do not use the Sensor in oily environments They may dam age parts and redu...

Page 8: ...put current flow that exceeds the rated current If a load short circuit occurs the output will turn OFF so check the wiring before turning ON the power supply again The short circuit protection circuit will be reset The load shortcircuit protection will operate when the current flow reaches 1 8 times the rated load current When using a capacitive load use an inrush current of 1 8 times the rated l...

Page 9: ... the output to go OFF in the beam spot position 4 Press the teaching button for approximately 0 5 second The teaching indicator red will light for approximately 0 5 second to show that the output OFF teaching is completed When Teaching Is Successful When Teaching Is Not Successful The stability indicator green shows that detection is stable The teaching indicator red flashes slowly Flashes in cycl...

Page 10: ...ontrol input is applied teaching has not been success ful Apply the remote control input again Precautions for Using Automatic Teaching Remote With automatic teaching remote the output is always turned ON for the light level with the shorter detection time Use 2 point teaching manual to turn OFF the output for the light level with the shorter detection time Faulty detection is possible when using ...

Page 11: ... M3 4 dia Vinyl insulated round cable with 4 conductors Conductor cross section 0 2 mm2 AWG 24 Insulator diameter 1 1 mm Standard length 2 m Stability indicator green Operation indicator yellow Optical axis 15 3 10 8 21 25 4 31 1 2 9 1 22 5 15 5 25 4 31 1 2 15 5 9 1 22 5 Teaching button Teaching indicator red Two M3 M8 1 Stability indicator green Operation indicator yellow Optical axis 3 2 7 8 15 ...

Page 12: ...erference or conditions or uses not described in this document Nuclear energy control systems combustion systems railroad sys tems aviation systems medical equipment amusement machines vehicles safety equipment and installations subject to separate in dustry or government regulations Systems machines and equipment that could present a risk to life or property Please know and observe all prohibitio...