A-426
Advanced Photoelectric Sensors
Differences from E3X-DA-N amplifier unit
Differential output type (edge detection type)
Item
Prewiring type
amplifier units with Connectors
Item
NPN output
E3X-DA11D
E3X-DA6D
Power consumption
Power consumption 960 mW max. (at power supply voltage 24 V, power consumption 40 mA max.)
Con-
trol
out-
put
ON/OFF output
Load current 50 mA (residual voltage NPN/PNP: 1 V max. each) Open collector output type L.ON (ON at edge
detection)/D.ON (OFF at edge detection) switch selectable
Detection mode
One-side edge detection mode/both-side edge detection mode
Response time
One-side edge detection mode: 270/500 s/1/2/4/10/20/30/50/100/200 ms selectable Both-side edge detection
mode: 570 s/1/2/4/10/20/30/50/100/200/400 ms selectable
Func
tions
Timer function
OFF delay timer for L.ON ON delay timer for D.ON 0 to 5 s (1 to 20 ms: 1 ms increments, 20 to 20 ms: 5 ms
increments, 200 ms to 1 s: 100 ms, 1 to 5 s: 1 s increments)
APC
Yes
Zero reset
Yes (negative indication)
Initial reset
Yes (setting conditions initialized)
Sensitivity
switching
Yes (HIGH/LOW)
Teaching level
One-point teaching level 1 to 50% variable (1% increments)
Indicator lamp
Operation indicator (orange), 7-segment incident level display (red), 7-segment digital edge detection level dis-
play (red)
For the outline drawings and other details, refer to the instruction manuals attached to the products.