A-430
Advanced Photoelectric Sensors
Operation
General
Digital incident level (4000 max.)
To reset to zero again:
Note: There is no limit on the number of times zero-reset can be used.
To return the initial digital incident level:
Hold down
both for 3 s.
*
Sensitivity increment
with threshold decrement
Sensitivity decrement
with threshold increment
Fine sensitivity adjustment
RUN mode
Digital incident level
Digital percent
Analog value
ADJ mode
Digital threshold
Digital Percent
Analog value
Select the channel to be
adjusted using the channel
selection switch.
Twin-output Models
Changing the Display (RUN Mode)
@
Manual Tuning (Fine Sensitivity Adjustment) in ADJ Mode
Perform fine sensitivity adjustment after teaching and manual tuning
(without using the teaching function) in the way shown below:
1
Zero-reset (RUN Mode)
Set the mode selector
to .
RUN
2
Initial Reset (SET Mode)
Set the mode selector
to .
SET
3
The items displayed in ADJ mode vary with the display
setting in RUN mode.
1s
1s
2s
2s
2s
TEACH
MODE
TEACH
TEACH
MODE
TEACH
TEACH
RUN
RUN
ADJ
TEACH
MODE
MODE
MODE
MODE
SET
CH1
CH2
MODE
MODE
Set the mode selector
to .
(Factory-set to RUN)
RUN
Digital incident level (4000 max.)
Digital Percent
Analog incident level and threshold
Set the mode selector
to .
ADJ
Cancel
Execute initial reset
Hold down
both for 5 s.