background image

7

Label Sensors

Safety precautions

This product is not designed or rated for directly or 
indirectly ensuring safety of persons. Do not use it for 
such a purpose.

Do not use the product with voltage in excess of the 
rated voltage. Excess voltage may result in malfunc-
tion or fire.

Never use the product with an AC power supply. 
Otherwise, explosion may result.

When cleaning the product, do not apply a high-pres-
sure spray of water to one part of the product. Other-
wise, parts may become damaged and the degree of 
protection may be degraded.

High-temperature environments may result in burn 
injury.

The following precautions must be observed to ensure safe 
operation of the Sensor.

Operating Environment

Do not use the Sensor in an environment where explosive or 
flammable gas is present.

Connecting Connectors

Be sure to hold the connector cover when inserting or removing 
the connector. Be sure to tighten the connector lock by hand; 
do not use pliers or other tools. If the tightening is insufficient, the 
degree of protection will not be maintained and the Sensor may 
become loose due to vibration. The appropriate tightening torque 
is 0.4 to 0.5 N·m for M12 connectors and 0.3 Nm for M8 connec-
tors.

Load

Do not use a load that exceeds the rated load.

Environements with Cleaners and Disinfectants 

Do not use the Sensor in environments subject to cleaners and 
disifectants. They may reduce the degree of protection.

Modifications

Do not attempt to disassemble, repair, or modify the Sensor.

Outdoor Use

Do not use the Sensor in locations subject to direct sunlight.

Surface Temperature

Burn injury may occur. The Sensor surface temperature rises de-
pending on application conditions, such as the surrounding tem-
perature and the power supply voltage. Use caution when 
operating or washing the Sensor.

Do not use the Sensor in any atmosphere or environment that 
exceeds the ratings.

Do not install the Sensor in the following locations.

(1) Locations subject to direct sunlight
(2) Locations subject to condensation due to high humidity
(3) Locations subject to corrosive gas
(4) Locations where the Sensor may receive direct vibration or 

shock

Connecting and Mounting

(1) The maximum power supply voltage is 35 VDC. Before turning 

the power ON, make sure that the power supply voltage does 
not exceed the maximum voltage.

(2) Laying Sensor wiring in the same conduit or duct as high-volt-

age wires or power lines may result in malfunction or damage 
due to induction. As a general rule, wire the Sensor in a sepa-
rate conduit or use shielded cable.

(3) Use an extension cable with a minimum thickness of 1 mm

2

 

and less than 100 m long.

(4) Do not pull on the cable with excessive force.
(5) Pounding the Sensor with a hammer or other tool during 

mounting will impair water resistance.

(6) Be sure to turn OFF the power supply before inserting or re-

moving the connector.

Power Supply

If a commercial switching regulator is used, ground the FG (frame 
ground) terminal.

Turning OFF the Power Supply

Output pulses may be generated even when the power supply is 
OFF. Therefore, it is recommended to first turn OFF the power 
supply for the load or the load line.

Load Short-circuit Protection

This Sensor is equipped with load short-circuit protection, but be 
sure to not short circuit the load. Be sure to not use an output cur-
rent flow that exceeds the rated current. 

Water Resistance

Do not use the Sensor in water, rainfall, or outdoors.

!

 Warning

!

 Caution

Precautions for Safe Use

Precautions for Correct Use

Summary of Contents for E3U-GL

Page 1: ...xact positioning without re adjust ment Features Stable operation and quick set up Stable operation eliminates the need to re adjust the sensor due to temperature changes or other influences during pr...

Page 2: ...CuZn PVC 2 m PUR 2 m XS2F M12PVC3S2M XS2F M12PUR3S2M XS2F M12PVC3A2M XS2F M12PUR3A2M 4 wire PVC 2 m PUR 2 m XS2F M12PVC4S2M XS2F M12PUR4S2M XS2F M12PVC4A2M XS2F M12PUR4A2M Item E3U GL1 E3U GL2 E3U GLK...

Page 3: ...re pulled through should be as high as possible For E3U GL1 For E3U GL2 The result of the auto teach procedure is indicated by the Status LED LED flashing 2x auto teach procedure successful The sen so...

Page 4: ...Remote auto teach For remote auto teach connect pin 2 white wire to the operating voltage The Status LED starts flashing quickly Move the la bels through the slot The result of the remote auto teach...

Page 5: ...U GLK32 M1 1 2 4 3 Brown Black White Blue 10 to 35VDC 0V NPN PNP Teach Lock 1 2 4 3 Brown Black White Blue 10 to 35VDC 0V NPN PNP 1 2 4 3 M8 Connector Pin Arrangement 1 4 2 3 Brown Black White Blue 10...

Page 6: ...E3U GLK31 M1 E3U GLK32 M1 Status LED yellow Power LED green Teach M8 x 1 29 5 11 12 28 14 M5 100 5 5 19 35 102 5 120 5 M8x1 Status LED Status LED Teach NO NC Teach M3 x 10 max 0 8 Nm Power LED Status...

Page 7: ...rises de pending on application conditions such as the surrounding tem perature and the power supply voltage Use caution when operating or washing the Sensor Do not use the Sensor in any atmosphere o...

Page 8: ...be suitable for the products Outdoor use uses involving potential chemical contamination or electrical interference or conditions or uses not described in this document Nuclear energy control systems...