      Do not place objects on top of communication cables. 
      Always wire communication cables through a duct. 
    Abide by the specifications for a communication distance and the 
    number of Units to be connected. 
    When replacing parts, be sure to confirm that the rating of a new part is 
    correct. Not doing so may result in malfunction or burning.
    Before touching the Unit, be sure to first touch a grounded metallic object 
    in order to discharge any static built-up. Not doing so may result in 
    malfunction or damage.
    Use a dedicated packing box to transport the Unit. Avoid excessive
    shock or vibration during transportation.
    Always use two end plates to keep certainly connection side by side 
    (E3NW-DS).

Please connect shield wire of a communication cable between the Distributed 
sensor unit to only a negative terminal of 24VDC of the dispersion unit of either. 
Please don't connect shield wire to both units. 
Mount the included ferrite cores (model: ZCAT1730-0730, manufacturer:
TDK Corporation) on both sides of the communication cable.

      

Unit Assembly Precautions

    When connecting the Power Supply Unit, CPU Unit, I/O Units, Special 
    I/O Units, or CPU Bus Units, slide the upper and lower sliders until a click 
    sound is heard to lock them securely. Desired functionality may not be
    achieved unless Units are securely locked in place.
    Be sure to mount the end cover supplied with the CPU Unit to the
    rightmost Unit. Unless the end cover is properly mounted, the CJ-series 
    PLC may not function properly.
      

Reference Manuals

Please be sure to read the related user manuals in order to use the PLC 
safely and properly. Be sure you are using the most current version of the 
manual.

Safety Precautions

OMRON Corporation

© 

OMRON Corporation 2013 All Rights Reserved

Thank you for purchasing an OMRON Distributed sensor unit. To ensure safe operation, please be sure to read this document along with the manuals 
for EtherCAT Slave Unit. Please be sure you are using the most recent versions of the user manuals. Contact your nearest OMRON representative to 
obtain manuals. Keep this document and all user manuals in a safe location and be sure that they are readily available to the final user of the products.

       

General Precautions 

 

The user must operate the product according to the performance 

specifications described in the operation manuals.

Before using the product under conditions which are not described in the 

manual or applying the product to nuclear control systems, railroad systems,

aviation systems, vehicles, combustion systems, medical equipment, 

amusement machines, safety equipment, petrochemical plants, and other 

systems, machines, and equipment that may have a serious influence on 

lives and property if used improperly, consult your OMRON representative.

Make sure that the ratings and performance characteristics of the product 

are sufficient for the systems, machines, and equipment, and be sure to 

provide the systems, machines, and equipment with double safety 

mechanisms.

     

Safety Precautions

Definition of Precautionary Information

      

DANGER

      

WARNING

        

Caution

Warnings and Cautions

       

WARNING

       

 WARNING

        

WARNING

        

WARNING

   Emergency stop circuits, interlock circuits, limit circuits, and similar safety  
   measures must be provided in external control circuits.
   The PLC will turn OFF all outputs when its self-diagnosis function detects 
   any error or when a severe failure alarm (FALS) instruction is executed. 
   As a countermeasure for such errors, external safety measures must be
   provided to ensure safety in the system.
   The PLC outputs may remain ON or OFF due to deposition or burning of 
   the output relays or destruction of the output transistors. As a 
   countermeasure for such problems, external safety measures must be  
   provided to ensure safety in the system.
   When the 24-VDC output (service power supply to the PLC) is 
   overloaded or shortcircuited, the voltage may drop and result in the
   outputs being turned OFF. As a countermeasure for such problems, 
   external safety measures must be provided to ensure safety in the system.

Indicates an imminently hazardous situation which, if 

not avoided, will result in death or serious injury.
Indicates a potentially hazardous situation which, if not 

avoided, could result in death or serious injury
Indicates a potentially hazardous situation which, if not 

avoided, may result in minor or moderate injury, or 

property damage.

Do not attempt to take any Unit apart while the power is 

being supplied. Doing so may result in electric shock.

Do not touch any of the terminals or terminal blocks 

while the power is being supplied. Doing so may result in 

electric shock.

Do not attempt to disassemble, repair, or modify any 

Units. Any attempt to do so may result in malfunction, 

fire, or electric shock.

Provide safety measures in external circuits, i.e., not in 

the Programmable Controller (CPU Unit including 

associated Units; referred to as “PLC”), in order to 

ensure safety in the system if an abnormality occurs due 

to malfunction of the PLC or another external factor 

affecting the PLC operation. Not doing so may result in 

serious accidents.

       

 

WARNING

        

WARNING

        

       

Transferring the contents of I/O Memory Area to the CPU Unit with a   

      Programming Device 

      Changing the present values with a Programming Device

      Force-setting/force-resetting any bit in memory with a Programming   

      Device

      Transferring the contents of I/O Memory Area to the CPU Unit with a     

      Memory Card or EM File Memory

      Transferring the contents of I/O Memory by another PLC or a host  

      computer on the network

         

Caution

       Caution

       

Operating Environment Precautions

         

Caution

  

     

Locations subject to direct sunlight

      Locations subject to temperatures or humidity outside the  range
      specified in the specifications
      Locations subject to condensation as the result of severe changes in 
      temperature 
      Locations subject to corrosive or flammable gases
      Locations subject to dust (especially iron dust) or salts
      Locations subject to exposure to water, oil, or chemicals (excluding the 
       waterproof type) 
      Locations subject to exposure to oil, acid, or chemicals (only for the
      waterproof type)
      Locations subject to shock or vibration

         

Caution

       

       

Locations subject to static electricity or other forms of noise

      Locations subject to strong electromagnetic fields
      Locations subject to possible exposure to radioactivity
      Locations close to power supplies

        

 Caution

Fail-safe measures must be taken by the customer to 

ensure safety in the event of incorrect, missing, or 

abnormal signals caused by broken signal lines, 

momentary power interruptions, or other causes. Not 

doing so may result in serious accidents.

The CPU Unit is I/O refreshing even in an 

operation-stopped state (Programming Mode). 

Therefore, confirm safety when changing data of Output 

bits allocated to Output Units, or of each CIO Area 

allocated to Special I/O Units or CPU Bus Units. 

Unexpected operation may occur in the loads connected 

to Output Units, Special I/O Units, or CPU Bus Units.

Pay careful attention to the polarities (+/-) when wiring. A 

wrong connection may cause malfunction of the system.

Tighten the screws on the terminal blocks to the torque 

specified in the operation manual. The loose screws may 

result in burning, malfunction, or a failure.

Do not install the Unit in the following places:

Take appropriate and sufficient countermeasures when 

using the Unit in the following locations:

The operating environment of the PLC System can have 

a large effect on the longevity and reliability of the system. 

Improper operating environments can lead to 

malfunction, failure, and other unforeseeable problems 

with the PLC System. Be sure that the operating 

environment is within the specified conditions at 

installation and remains within the specified conditions 

during the life of the system.

  

       

Application Precautions

     

        

WARNING

    

Always connect to 100 Ω or less when installing the Units. Not 

    connecting to a ground of 100 Ω or less may result in electric shock. 

    Mount the Units securely to a DIN Track or with screws. 

    Always turn OFF the power supply to the PLC, Slave Units, and 

    communication devices, before attempting any of the following. Not 

    turning OFF the power supply may result in malfunction or electric shock.

      Mounting or dismounting I/O Units, CPU Units, Power Supply Units,  

      Memory Cassettes, Master Units, or any other Units

      Mounting or dismounting terminal blocks on Remote I/O terminals

      Assembling the Units

      Setting DIP switches or rotary switches

      Connecting or wiring the cables

        

          

Caution

     

Always use the power supply voltage specified in the operation manuals. 

    An incorrect voltage may result in malfunction or burning.

    Take appropriate measures to ensure that the specified power with the 

    rated voltage and frequency is supplied. Be particularly careful in places  

    where the power supply is unstable. An incorrect power supply may 

    result in malfunction.

    Install external breakers and take other safety measures against 

    short-circuiting in external wiring. Insufficient safety measures against 

    short-circuiting may result in burning.

    Do not apply voltages to the Input Units in excess of the rated input 

    voltage. Excess voltages may result in burning.

    Do not apply voltages or connect loads to the Output Units in excess of

    the maximum switching capacity. Excess voltage or loads may result in

    burning.

    Install the Unit properly as specified in the operation manual. Improper 

    installation of the Unit may result in malfunction.

    Be sure that all the terminal screws and cable connector screws of Slave 

    Units are tightened to the torque specified in the relevant manuals.  

    Incorrect tightening torque may result in malfunction.

    Use correct wiring parts for wiring. 

    Wire correctly and double-check all the wiring or the setting switches 

    before turning ON the power supply. Incorrect wiring may result in 

    burning.

    Do not let a piece of metal enter the Units when wiring or installing.

    Be careful of voltage ratings when wiring a communication path with the 

    Power Supply Unit and I/O Units. Wrong wiring may cause a failure. 

    Wire correctly as specified in the manual.

    Be sure that the terminal blocks, communication cables, and other items 

    with locking devices are properly locked into place. Improper locking may 

    result in malfunction. 

    Check the user program for proper execution before actually running it

    on the Unit. Not checking the program may result in an unexpected

    operation. 

    Do not drop the Units or give the Units excessive vibration or shock.

    Doing so may cause a failure or malfunction. 

    Confirm that no adverse effect will occur in the system before attempting 

    any of the following. Not doing so may result in an unexpected operation.

      Changing the operating mode of the PLC

      Force-setting/force-resetting any bit in memory.

      Changing the present value or any set value of any word in a user program

    Resume operation only after transferring to the new CPU Unit and/or 

    Special I/O Units the contents of the DM and HR Areas required for 

    resuming operation. Not doing so may result in an unexpected operation.

    Tighten the screws on the cover to the specified torque after setting the 

    rotary switches and wiring. Insufficient tightening torque may result in an 

    inadequate protective structure. (Only for the waterproof type)

    Do not pull on the cables or bend the cables beyond their natural limit.  

    Doing either of these may break the cables. 

    Always use specified communication cables and connectors. 

    Be careful of the following when wiring communication cables.

      Keep communication cables away from power lines and high-voltage lines. 

      Do not bend communication cables. 

      Do not pull communication cables excessively.

Always heed these precautions. Failure to abide by the 

following precautions could lead to serious or possibly 

fatal injury.

Failure to abide by the following precautions could lead to 

faulty operation of the PLC or the system, or could 

damage the PLC or PLC Units. Always heed these 

precautions.

9908973-8C

Model/Manual name

E3NW-ECT

Operation Manual

E3NW-ECT

E3NW-DS

OMRON Corporation

Suitability for Use

EUROPE

OMRON EUROPE B.V. Sensor Business Unit

Carl-Benz Str.4, D-71154 Nufringen Germany

Phone:49-7032-811-0  Fax: 49-7032-811-199

NORTH AMERICA

OMRON ELECTRONICS  LLC

One Commerce Drive Schaumburg,IL 60173-5302 U.S.A.

Phone:1-847-843-7900  Fax : 1-847-843-7787

ASIA-PACIFIC

OMRON ASIA PACIFIC PTE. LTD.

No. 438A Alexandra Road #05-05-08(Lobby 2),

Alexandra Technopark, Singapore 119967 

Phone : 65-6835-3011  Fax :65-6835-2711

o

THE PRODUCTS CONTAINED IN THIS SHEET ARE NOT SAFETY 

RATED.  THEY ARE NOT DESIGNED OR RATED FOR ENSURING 

SAFETY OF PERSONS, AND SHOULD NOT BE RELIED UPON AS A 

SAFETY COMPONENT OR PROTECTIVE DEVICE FOR SUCH 

PURPOSES.

Please refer to separate catalogs for OMRON's safety rated products.
OMRON shall not be responsible for conformity with any standards, codes, 

or regulations that apply to the combination of the products in the 

customer's application or use of the product. 

 

Take all necessary steps to determine the suitability of the product for the 

systems, machines, and equipment with which it will be used.

Know and observe all prohibitions of use applicable to this product.

 

NEVER USE THE PRODUCTS FOR AN APPLICATION INVOLVING 

SERIOUS RISK TO LIFE OR PROPERTY WITHOUT ENSURING THAT 

THE SYSTEM AS A WHOLE HAS BEEN DESIGNED TO ADDRESS THE 

RISKS, AND THAT THE OMRON PRODUCT IS PROPERLY RATED AND 

INSTALLED FOR THE INTENDED USE WITHIN THE OVERALL 

EQUIPMENT OR SYSTEM.

See also Product catalog for Warranty and Limitation of Liability.

CHINA

OMRON(CHINA) CO., LTD. 

Room 2211, Bank of China Tower,

200 Yin Cheng Zhong Road, 

PuDong New Area, Shanghai, 200120, China

Phone : 86-21-5037-2222  Fax :86-21-5037-2200

OCT, 2009

Manufacturer:

  Omron Corporation,

  Shiokoji Horikawa, Shimogyo-ku,

  Kyoto 600-8530 JAPAN

  Shanghai Factory

  No.789 Jinji Road,

  Jinqiao Export Processing District,

  Pudong New Area,Shanghai,201206 CHINA

  

TRACEABILITY INFORMATION:

Representative in EU:

  Omron Europe B.V.

  Wegalaan 67-69

  2132 JD Hoofddorp,

  The Netherlands

E3NW-DS

Distributed sensor unit

Cat No.
E429 

Reviews: