![background image](http://html1.mh-extra.com/html/omron/e3mc/e3mc_manual_741092012.webp)
E3MC
E3MC
E3MC-MA
/E3MC-MX
-- -- 4-Output Models
1.
Channel Selection
Set the Mode Selector to the TEACH mode.
Then select the channel using the SELECT button.
2.
Color Registration
Position the registered object at the detection point
and press the TEACH button.
All the red threshold
indicators will flash if
registration has not been
completed.
All the detection level
indicators are illuminated.
Registered object
OK
No Good
Sensor
3.
Threshold Adjustment (If Required)
Sensor
Sensing object
Press the SELECT button in ADJ mode with or without the object
to be detected positioned at the detection point. The channel
selected in the TEACH mode or RUN mode will become the
channel for the ADJ mode.
Detection Level and Tolerance
As the detected color becomes closer to the registered color, the
number of illuminated detection level indicators increases. When
the E3MC is in conforming output mode, the control output will be
ON if the detection level exceeds the threshold level and OFF if
the detection level does not exceed the threshold level.
Set the threshold to a higher level for highly-precise color
discrimination and to a lower level to ignore minor tint differences
or dirt accumulation.
Detection level
Operation
indicator:
illuminated
Control output:
ON
Tolerance
Threshold
value
Detection level
Threshold
value
Operation
indicator: Not
illuminated
Control output:
OFF
www.DataSheet4U.com