![Omron E3MC - Manual Download Page 13](http://html1.mh-extra.com/html/omron/e3mc/e3mc_manual_741092013.webp)
E3MC
E3MC
4.
Operation
For indicating detection level and threshold value for other channels
Press the SELECT button.
For checking which channel
is indicated with the operation
indicator.
Press the
TEACH button.
Displays the channel whose detection
level is currently indicated in the
channel indicator for three seconds.
Displays the selected channel for
three seconds and indicates
detection level and threshold value
of the selected channel.
The detection operation is performed in RUN
mode. ON/OFF status of each channel is
displayed on the channel indicators. Doubly
displayed channels (operation indicator and
channel indicator) can be checked and
selected by pressing the TEACH button and
selected by pressing the SELECT button.
DETECTION LEVEL AND INDICATOR
Indicator
Detection
level
1
2
3
4
5
6
7
8
TECHNICAL GUIDE
If the E3MC does not detect metal or glossy objects accurately, change the mounting angle of the E3MC so that it will not receive regular
reflection light directly reflected from the objects.
The mounting angle of the E3MC-X
can be adjusted to approximately 10
°
with the mounting holes.
Object to be detected
Object to be detected
E3MC-X
E3MC-A
Note: To avoid malfunction, provide a cover to shut out direct
external light interference to the E3MC.
Sensing target
E3MC-(M)Y
(reflective optical fiber)
0 to 20
°
On the other hand, sensing targets such as metal or transparent
plastic cases may be detected by allowing regular reflection.
Detection of White, Gray, or Black Objects
When registering white, gray, or black objects, change the color
discrimination mode to “Mode I” to achieve a more stable color
discrimination.
External Light
The E3MC may malfunction if it directly receives external light
interference. Provide a cover to shut-out such external light
interference.
www.DataSheet4U.com