Note:

1. Definition of Sensing Distance

Refer to the following table and the diagram to the right.

2.

1-output models only: E3MC-A

@@

/-X

@@

/-Y

@@

3.

4-output models only: E3MC-MA

@@

/-MX

@@

/-MY

@@

4.

0.75-mm double amplitude or 100 m/s

2

 when using a Mounting Bracket.

5.

300 m/s

2

 when using a Mounting Bracket.

6.

Refer to page 13 for 

Remote Teaching

.

Standard Sensing Objects

Discriminating color 
selection (1-output 
model only)

4 banks selectable (either by bank selection input or by using the SELECT button)
Input response time for bank selection: 50 ms max.

Indicator

Operation indicator (orange LED), 4-level bank indicator (green LED, see note 2), 7-level threshold indicator 
(red LED), 8-level detection indicator (green LED), and four channel indicators (orange LED, see note 3)

Protection

Protection from reversed power supply connection and output short-circuit

Ambient illumination

Incandescent lamp: Illumination on optical spot: 3,000 lx max.
Sunlight:

Illumination on optical spot: 10,000 lx max.

Ambient temperature

Operating: –25

°

C to 55

°

C (with no icing)

Ambient humidity

Operating: 35% to 85% (with no condensation)

Permissible fiber bend-
ing radius

---

10 mm min.

Varies with the type of recommend-
ed fiber

Insulation resistance

20 M

 min. (at 500 VDC)

Dielectric strength

1,000 VAC, 50/60 Hz for 1 min.

Vibration resistance

Destruction: 10 to 55 Hz, 1.0-mm double amplitude or 150 m/s

2

 for 2 hrs each in X, Y, and Z directions (see 

note 4)

Shock resistance

Destruction: 500 m/s

2

 for 3 times each in X, Y, and Z directions (see note 5)

Degree of protection

IEC IP66 (with protective cover in place)

Material

Case:

Zinc die-cast

Cover:

PES

Case:

Zinc die-cast

Cover:

PES

Fiber head:

ABS

Case:

Zinc die-cast

Cover:

PES

Weight (with 2-m cord)

Approx. 350 g

Approx. 400 g

Approx. 350 g

Item

Built-in amplifier type

Optical fiber type

General-purpose optical fiber 

type

E3MC-A

@

1, E3MC-MA

@

1

E3MC-X

@

1, E3MC-MX

@

1

E3MC-Y

@

1, E3MC-MY

@

1

Item

E3MC-(M)A

@@

E3MC-(M)X

@@

Color discrimination 
mode

Mode C

Response time

Standard mode

Tolerance (

θ

)

15

°

10

°

Detectable colors

11 standard colors

E3MC-(M)X

@@

Fiber Head

Sensing object

E3MC-(M)A

@@

Sensing object

Color 

(11 standard colors)

Munsell color notation

White

N9.5

Red

4R

4.5/12.0

Yellow/red

4YR 6.0/11.5

Yellow

5Y

8.5/11.0

Yellow/green

3GY 6.5/10.0

Green

3G

6.5/9.0

Blue/green

5BG 4.5/10.0

Blue

3PB

5.0/10.0

Blue/purple

9PB

5.0/10.0

Purple

7P

5.0/10.0

Red/purple

6RP 4.5/12.5

Summary of Contents for E39-C1

Page 1: ...utput models are also available Ordering Information RGB Color Sensor Note 1 Refer to Specifications on page 3 2 Eleven colors are discriminated at this distance For a typical example nine colors are...

Page 2: ...ely sold Appearance Name Sensor Mounting Bracket DIN track Mounting Bracket Use When mounting the E3MC Can be inclined to 15 When mounting to the DIN track Model E39 L114 E39 L115 Appearance Detection...

Page 3: ...able Mode selection Remote control input see note 6 mode B only The following control is performed according to the control signal input E3MC 11 41 Bank selection remote teaching or threshold selectio...

Page 4: ...h no condensation Permissible fiber bend ing radius 10 mm min Varies with the type of recommend ed fiber Insulation resistance 20 M min at 500 VDC Dielectric strength 1 000 VAC 50 60 Hz for 1 min Vibr...

Page 5: ...reen Blue green Blue Blue purple Purple Red purple Sensing distance mm Detection level Detection level Sensing Distance vs Color Differences Typical Angle Characteristics Typical Angle Characteristics...

Page 6: ...mm E32 T16 200 mm E32 T17L 1 1 m Operating Range Characteristics Typical E32 DC200 E32 CC200 E32 D32L Sensing object Blue Green 38 x 38 mm Sensing object Blue Green 38 x 38 mm Sensing object Blue Gree...

Page 7: ...on Threshold adjustment Mode Selector Selects TEACH ADJ or RUN mode Function Switch Color discrimination mode selection Response time selection OFF delay timer setting Conformity Non conformity output...

Page 8: ...ithin the rated sensing range Mode I Color discrimination is performed according to RGB light intensity of reflection light This mode ensures more delicate color discrimination than mode C 3 ms 6 ms T...

Page 9: ...green Main circuit Operation indicator orange 7 level threshold indicator red Control output Bank selection input 1 Remote control input Bank selection input 2 Not used External synchronous input Exte...

Page 10: ...the detection level does not exceed the threshold level provided that the E3MC is in conformity output mode Set the threshold to a higher level for highly precise color discrim ination and to a lower...

Page 11: ...bject OK No Good Sensor Locate the registered object at the detection point and press the TEACH button All the red threshold indicators will flash if registration has not been completed Refer to Techn...

Page 12: ...ment of its sensing distance depending on the reflection rate This also applies to the thru beam type Registered Color Selection Bank Selection Input 1 output Models Only The E3MC in RUN mode allows...

Page 13: ...ut will be accepted 5 The same switching procedure can be used for chang ing to mode A Remote Teaching Method Function 1 Remote teaching with manual input through a mechanical switch Short circuit the...

Page 14: ...Answer back output ON OFF ON OFF Input detection Bank 1 designated Input detection Answer back output with teaching OK No output if teaching fails Sensing restarts Teach ing An interval of 0 6 s min...

Page 15: ...wo M2 6 x 6 Four M5 holes on both sides depth 5 5 E3MC X E3MC MX Receiver Emitter Sensing face 9 1 x 22 9 Optical axis 3 3 dia mounting holes Sensing head heat resistive ABS 6 dia optical fiber standa...

Page 16: ...es Two 2 4 dia Receiver section Emitter section Fiber Unit mounting screw Four M5 holes on both sides depth 5 5 Mounting Dimensions Amplifier Unit Sensor I O Connector E39 C1 2M 2 m E39 C1 5M 5 m 6 di...

Page 17: ...nless steel SUS430 E39 C1 2M E39 C1 5M Internal Wiring White Brown Green Yellow Pink Blue Lead wire color Gray Note Pin 8 is not used Pin no Wire color Purpose E3MC 11 E3MC 41 E3MC M 11 E3MC M 41 1 Wh...

Page 18: ...ue of 0 2 N m Fibers Among the recommended fibers the E32 CC200 and E32 D32L have white or dotted yellow lines on the fiber to be inserted into the emitter When using the E3MC M Y insert the fiber wit...

Page 19: ...E3MC Power Supplies Be sure to ground the FG frame ground and G ground termi nals if a switching regulator is connected to the E3MC otherwise the E3MC may malfunction due to the switching noise of th...

Page 20: ...e direction indicated by arrow 6 Then lift up the E3MC in the direction indi cated by arrow 7 to remove the E3MC with the E39 L115 E3MC E39 L115 Mounting Bracket M5 screws M3 screw 1 DIN track 2 M3 sc...

Page 21: ...may be suitable for the products Outdoor use uses involving potential chemical contamination or electrical interference or conditions or uses not described in this catalog Nuclear energy control syste...