37
• Fiber Connection
The E3X Amplifier Unit has a lock button for easy connection of the
Fiber Unit. Connect or disconnect the fibers using the following pro-
cedures:
1. Connection
Open the protective cover, insert the fibers according to the fiber
insertion marks on the side of the Amplifier Unit, and lower the lock
button.
Fibers with E39-F9 Attachment
Fibers That Cannot Be Free-Cut (with Sleeves)
2. Disconnecting Fibers
Remove the protective cover and raise the lock button to pull out the
fibers.
Note 1.
To maintain the fiber properties, confirm that the lock is re-
leased before removing the fibers.
2.
Be sure to lock or unlock the lock button within an ambient
temperature range between
−
10
°
C and 40
°
C.
• Protective Cover
Always keep the protective cover in place when using the Amplifier
Unit.
Lock button
Fiber
Fiber insertion
mark
Locked
Unlocked
Insertion position
Protective cover
9 mm
Fiber Unit
9 m m
1 3 m m
9 m m
1 3 m m
Locked
Unlocked
Protective cover
Note:
For complete precautions and installation instructions refer to individual amplifier datasheets.