background image

D-63

E2S

E2S

Rating/Performance

DC 2-wire Models

* The response frequencies for DC switching are average values measured under the condition that the distance between each sensing object is twice as large as the

size of the sensing object and the sensing distance set is half of the maximum sensing distance.

DC 3-wire Models

* The response frequencies for DC switching are average values measured under the condition that the distance between each sensing object is twice as large as the

size of the sensing object and the sensing distance set is half of the maximum sensing distance.

Model

E2S-W11
E2S-W12

E2S-Q11
E2S-Q12

E2S-W21
E2S-W22

E2S-Q21
E2S-Q22

Item

Sensing surface

Front face

End face

Front face

End face

Sensing distance

1.6 mm ±10%

2.5 mm ±15%

Setting distance

0 to 1.2 mm

0 to 1.9 mm

Differential distance

10% max.

Sensing object

Ferrous metal (Sensitivity lowers with non-ferrous metals)

Standard sensing 
object

Iron, 12 x 12 x 1 mm

Iron, 15 x 15 x 1 mm

Response frequency

1 kHz min.

Rated supply voltage 
(operating voltage)

12 to 24 VDC (10 to 30 VDC), ripple (p-p): 10% max.

Leakage current

0.8 mA max.

Control 
output

Switching 
capacity

3 to 50 mA DC max.

Residual 
voltage

3 V max. (under load current of 50 mA with cable length of 1 m)

Indicator lamp

##

1 models: Operation indicator(red LED), Operation set indicator(green LED)  

##

2 models: Operation indicator(red LED)

Operating status 
(with sensing object 
approaching)

##

1 models: NO

##

2 models: NC

Model

E2S-W13
E2S-W14

E2S-Q13
E2S-Q14

E2S-W23
E2S-W24

E2S-Q23
E2S-Q24

E2S-W15
E2S-W16

E2S-Q15
E2S-Q16

E2S-W25
E2S-W26

E2S-Q25
E2S-Q26

Item

Sensing surface

Front face

End face

Front face

End face

Front face

End face

Front face

End face

Sensing distance

1.6 mm ±10%

2.5 mm ±15%

1.6 mm ±10%

2.5 mm ±15%

Setting distance

0 to 1.2 mm

0 to 1.9 mm

0 to 1.2 mm

0 to 1.9 mm

Differential distance

10% max.

Sensing object

Ferrous metal

Standard sensing 
object

Iron, 12 x 12 x 1 mm

Iron, 15 x 15 x 1 mm

Iron, 12 x 12 x 1 mm

Iron, 15 x 15 x 1 mm

Response frequency

1 kHz min.

Rated supply voltage 
(operating voltage)

12 to 24 VDC (10 to 30 VDC), ripple (p-p): 10% max.

Current consumption

13 mA max. (24 VDC, unload)

Control 
output

Switching 
capacity

NPN open collector 100 mA max. (30 VDC max.)

PNP open collector 50 mA max. (30 VDC max.)

Residual 
voltage

1 V max. (under load current of 50 mA with cable length of 1 m)

Indicator lamp

Operation indicator (orange)

Operating status 
(with sensing object 
approaching)

##

3 models: NO

##

4 models: NC

##

5 models: NO

##

6 models: NC

F502-EN2-04.book  Seite 63  Dienstag, 26. Juli 2005  5:48 17

Summary of Contents for E2S

Page 1: ...otection IEC60529 IP67 Significantly lower current consumption The 0 8 mA for 24 VDC leakage current for the DC 2 wire type has a ratio of ap proximately 1 20 compared to the conventional DC 3 wire type Optimum solution for multiple sensor applications such as cam switches 5 5 mm Adopted for more compact machines and devices 5 5mm 1 kHz IP67 1 20 Ultra small housing High Speed Response Environment...

Page 2: ...ions Model Operating status NO NC Front face NPN E2S W13 E2S W14 End face E2S Q13 E2S Q14 Front face E2S W23 E2S W24 End face E2S Q23 E2S Q24 Front face PNP E2S W15 E2S W16 End face E2S Q15 E2S Q16 Front face E2S W25 E2S W26 End face E2S Q25 E2S Q26 Shape Model Quantity Remarks Y92E C1R6 1 Provided with E2S 1 Y92E C2R5 Provided with E2S 2 Y92E D1R6 Y92E D2R5 Unshielded 1 6mm 2 5mm Unshielded 1 6mm...

Page 3: ...ching capacity 3 to 50 mA DC max Residual voltage 3 V max under load current of 50 mA with cable length of 1 m Indicator lamp 1 models Operation indicator red LED Operation set indicator green LED 2 models Operation indicator red LED Operating status with sensing object approaching 1 models NO 2 models NC Model E2S W13 E2S W14 E2S Q13 E2S Q14 E2S W23 E2S W24 E2S Q23 E2S Q24 E2S W15 E2S W16 E2S Q15...

Page 4: ...tween energized parts and case Dielectric strength 1 000 VAC for 1 min between energized parts and case Vibration resistance 10 to 55 Hz 1 5 mm double amplitude for 2 hours each in X Y and Z directions Shock resistance Destruction 500 m s2 for 3 times each in X Y and Z directions Protective structure IEC60529 IP67 Connection method Pre wired models Standard length 3 m Weight Packed state Approx 10...

Page 5: ...Sensor ON OFF ON OFF ON OFF Setting indicator green Operation indicator red Control output Load Brown Blue Main circuit V 0V 100 0 Sensing object Sensing zone Non sensing zone Non sensing zone Proximity Sensor ON OFF ON OFF Operation indicator red Control output Yes No ON OFF ON OFF Sensing object Operation indicator orange Output transistor load Load Brown Black Output Blue Main circuit V 0V Maxi...

Page 6: ...adjacent Sensors to suppress mutual interference as provided in the following diagram Unit mm Note The above values in parentheses are applicable when using two sensors with different frequencies Mounting Tightening torgues Do not tighten the E2S W Q 2 mounting screws to a torque exceeding 0 7 Nm Correct Use Model Length A B C E2S W1 0 8 2 E2S W2 15 10 Model Length A B C E2S Q1 8 3 2 E2S Q2 15 10 ...

Page 7: ...conductor sectional area 0 14mm2 Insulator diameter 0 9 dia standard length 1 m 7 4 7 8 2 3 11 3 20 3 10 8 2 5 2 2 3 1 dia If mounting bracket is attached E2S Q2 If mounting bracket is attached 8 8 4 8 2 3 8 9 14 5 3 6 4 1 18 5 11 3 23 3 Sensing surface Indicator 2 9 dia vinyl insulated round cable 2 3 cores conductor sectional area 0 14m u Insulator diameter 0 9 dia standard length 1 m 10 8 3 1 d...

Page 8: ... of product improvement specifications are subject to change without notice ALL DIMENSIONS SHOWN ARE IN MILLIMETERS To convert millimeters into inches multiply by 0 03937 To convert grams into ounces multiply by 0 03527 Cat No E902 E2 02 X ...