background image

3

E2AG

Specifications

Item

M8

M12

M18

M30

Shielded

Unshielded

Shielded

Unshielded

Shielded

Unshielded

Shielded

Unshielded

E2AG-
S08KS01-

@

-B1

E2AG-
S08KS01-

@

-B2

E2AG-
S08KN02-

@

-B1

E2AG-
S08KN02-

@

-B2

E2AG-
M12KS02-

@

-B1

E2AG-
M12KS02-

@

-B2

E2AG-
M12KN05-

@

-B1

E2AG-
M12KN05-

@

-B2

E2AG-
M18KS05-

@

-B1

E2AG-
M18KS05-

@

-B2

E2AG-
M18KN10-

@

-B1

E2AG-
M18KN10-

@

-B2

E2AG-
M30KS10-

@

-B1

E2AG-
M30KS10-

@

-B2

E2AG-
M30KN18-

@

-B1

E2AG-
M30KN18-

@

-B2

Sensing 
distance

1.5 mm ±10%

2 mm ±10%

5 mm ±10%

10 mm ±10%

18 mm ±10%

Differential travel 10% max. of sensing distance

Detectable 
object

Ferrous metal (The sensing distance decrease with non-ferrous metal. Refer to Engineering Data on pages 4 and 5)

Standard 
sensing object

Iron 
8×8×1 mm

Iron 
12×12×1 mm

Iron 
15×15×1 mm

Iron 
18×18×1 mm

Iron 
30×30×1 mm

Iron 
54×54×1 mm

Response 
frequency

*1

*1.

The response frequency is an average value. Measurement conditions are as follows:standard sensing object, a distance of twice the standard sensing object, and
a set distance of half the sensing distance.

1 kHz

0.4 kHz

0.8 kHz

0.1 kHz

0.5 kHz

0.1 kHz

0.1 kHz

0.1 kHz

Power supply 
voltage 
(operating 
voltage range)

12 to 24 VDC. Ripple(p-p):10% max.
(10~30 VDC)

Current 
consumption

13 mA max.

Con

tro

l

o

ut

put

Load 
current

open collector, 200 mA max.

Residual 
voltage

2 V max. (under load current of 200 mA with cable length of 2 m)

Indicator

Operation indicator (yellow)

Operation mode 
(with sensing 
object 
approaching)

B1 Models: NO
B2 Models: NC

Refer to the timing charts under Output Circurt Diagrams of page 7 for details.

Protection 
circuits

Reverse polarity protection,Surge suppressor,Load short-circurt protection

Ambient 
temperature 
range

Operating / Storage: -25~+70°C (with no icing or condensation)

Ambient 
humidity range

Operating / Storage: 35~95% RH

Voltage 
influence

±10% max. of sensing distance in rated voltage range ±15%

Insulation 
resistance

50 M

Ω

 min. (at 500 VDC) between current carry parts and case

Dielectric 
strength

1,000 VAC, 50/60 Hz for 1 minute between current carry parts and case

Vibration 
resistance

10~55 Hz 0.75 mm double amplitude for 2 hours each in X,Y,and Z directions

Shock 
resistance

500 m/s² 10 times 
each in X,Y,and Z directions

1,000 m/s² 10 times each in X,Y,and Z directions

Degree of 
protection

IEC 60529 IP67

Connection 
method

Pre-wired models (Standard cable length: 2 m)

Weight

Approx. 55 g

Approx. 65 g

Approx. 140 g

Approx. 190 g

Mate

rials

Case

Stainless steel (SUS303)

Nickel plated brass

Sensing 
surface

PBT

Summary of Contents for E2AG

Page 1: ...sing distance Output Type Operation mode NO Operation mode NC Shielded M8 PNP E2AG S08KS01 WP B1 E2AG S08KS01 WP B2 M12 E2AG M12KS02 WP B1 E2AG M12KS02 WP B2 M18 E2AG M18KS05 WS B1 E2AG M18KS05 WS B2...

Page 2: ...mm 6 Kind of connection WP pre wired PVC dia 4 mm WS pre wired PVC dia 6 mm 7 Power Source and Output B DC 3 wire PNP open collector 8 Operation mode 1 Normally open NO 2 Normally closed NC 9 Cable l...

Page 3: ...le p p 10 max 10 30 VDC Current consumption 13 mA max Control output Load current open collector 200 mA max Residual voltage 2 V max under load current of 200 mA with cable length of 2 m Indicator Ope...

Page 4: ...10 C B E2AG M18KS05 C B E2AG M12KS02 C B E2AG S08KS01 C B Distance X mm Distance Y mm E2AG M30KN18 C B E2AG S08KN02 C B E2AG M12KN05 C B E2AG M18KN10 C B Distance X mm Distance Y mm E2AG S08KS01 C B D...

Page 5: ...g object d mm Iron Iron Stainless steel Stainless steel Brass Brass Aluminum Aluminum Copper Distance X mm Distance X mm Iron Stainless steel Aluminum E2AG M18KN10 C B E2AG M30KN18 C B Side length of...

Page 6: ...VC round insulated cable 3 wire dia 4 cross section of conductor 0 3mm insulator diameter 1 3mm standard 2m cable indicator 1 2 clamping nuts toothed washer 1 PVC round insulated cable 3 wire dia 4 cr...

Page 7: ...e Incorrect connection Ensure that the power suppy polarity and other wiring is correct oth erwise incorrect wiring may cause explosion or burning Output Model Operation mode Timing chart Output circu...

Page 8: ...8 Cylindrical Proximity Sensor In the interest of product improvement specifications are subject to change without notice Cat No E61E EN 01...

Reviews: