![background image](http://html1.mh-extra.com/html/omron/e2ag/e2ag_datasheet_740820003.webp)
3
E2AG
Specifications
Item
M8
M12
M18
M30
Shielded
Unshielded
Shielded
Unshielded
Shielded
Unshielded
Shielded
Unshielded
E2AG-
S08KS01-
@
-B1
E2AG-
S08KS01-
@
-B2
E2AG-
S08KN02-
@
-B1
E2AG-
S08KN02-
@
-B2
E2AG-
M12KS02-
@
-B1
E2AG-
M12KS02-
@
-B2
E2AG-
M12KN05-
@
-B1
E2AG-
M12KN05-
@
-B2
E2AG-
M18KS05-
@
-B1
E2AG-
M18KS05-
@
-B2
E2AG-
M18KN10-
@
-B1
E2AG-
M18KN10-
@
-B2
E2AG-
M30KS10-
@
-B1
E2AG-
M30KS10-
@
-B2
E2AG-
M30KN18-
@
-B1
E2AG-
M30KN18-
@
-B2
Sensing
distance
1.5 mm ±10%
2 mm ±10%
5 mm ±10%
10 mm ±10%
18 mm ±10%
Differential travel 10% max. of sensing distance
Detectable
object
Ferrous metal (The sensing distance decrease with non-ferrous metal. Refer to Engineering Data on pages 4 and 5)
Standard
sensing object
Iron
8×8×1 mm
Iron
12×12×1 mm
Iron
15×15×1 mm
Iron
18×18×1 mm
Iron
30×30×1 mm
Iron
54×54×1 mm
Response
frequency
*1
*1.
The response frequency is an average value. Measurement conditions are as follows:standard sensing object, a distance of twice the standard sensing object, and
a set distance of half the sensing distance.
1 kHz
0.4 kHz
0.8 kHz
0.1 kHz
0.5 kHz
0.1 kHz
0.1 kHz
0.1 kHz
Power supply
voltage
(operating
voltage range)
12 to 24 VDC. Ripple(p-p):10% max.
(10~30 VDC)
Current
consumption
13 mA max.
Con
tro
l
o
ut
put
Load
current
open collector, 200 mA max.
Residual
voltage
2 V max. (under load current of 200 mA with cable length of 2 m)
Indicator
Operation indicator (yellow)
Operation mode
(with sensing
object
approaching)
B1 Models: NO
B2 Models: NC
Refer to the timing charts under Output Circurt Diagrams of page 7 for details.
Protection
circuits
Reverse polarity protection,Surge suppressor,Load short-circurt protection
Ambient
temperature
range
Operating / Storage: -25~+70°C (with no icing or condensation)
Ambient
humidity range
Operating / Storage: 35~95% RH
Voltage
influence
±10% max. of sensing distance in rated voltage range ±15%
Insulation
resistance
50 M
Ω
min. (at 500 VDC) between current carry parts and case
Dielectric
strength
1,000 VAC, 50/60 Hz for 1 minute between current carry parts and case
Vibration
resistance
10~55 Hz 0.75 mm double amplitude for 2 hours each in X,Y,and Z directions
Shock
resistance
500 m/s² 10 times
each in X,Y,and Z directions
1,000 m/s² 10 times each in X,Y,and Z directions
Degree of
protection
IEC 60529 IP67
Connection
method
Pre-wired models (Standard cable length: 2 m)
Weight
Approx. 55 g
Approx. 65 g
Approx. 140 g
Approx. 190 g
Mate
rials
Case
Stainless steel (SUS303)
Nickel plated brass
Sensing
surface
PBT