background image

7

E2AG

Output circuit

Correct use

Effects of surrounding metal

Please keep the distance as the demensions of the following chart 
away from the surrounding metal.

Mutual interference

Please use the value shown as the following chart when the the 
products are oppsite or parallel configurated.

Precaution for safe use

Power supply voltage

Do not use a voltage which exceeds the range of the rated voltage. 
Applying a voltage that is higher than the rated voltage or using an 
AC supply (220 V) for the sensor may cause sensor explosion or 
burning.

Load short-circuiting

Do not short-circuit the load,otherwise explosion or burning may 
occur. The load short-circuit protection function operates when the 
power supply is connected with the correct polarity and the power is 
within the rated voltage range.

Incorrect connection

Ensure that the power suppy polarity and other wiring is correct, oth-
erwise incorrect wiring may cause explosion or burning.

Output

Model

Operation

mode

Timing chart

Output circuit

PNP 
Open 
collector 
output

E2AG-

@

-

@

-B1 NO

E2AG-

@

-

@

-B2 NC

(

%

)

100                                 0

Detection

o

b

ject

Proximity 

s

witch

Non-

s

en

s

ing

 zone

S

en

s

ing

 zone

R

a

ted

detection

di

s

t

a

nce

ON

OFF

ON

OFF

Oper

a

tion

indic

a

tor

(yellow)

O

u

tp

u

t

control

NOTE:

 

ABCD

 

a

re the pin

s

' n

u

m

b

er

s

 of the Connector.

Lo

a

d

A

D

 (or 

B

)

C

Brown

Bl

a

ck

Bl

u

e

Proximity

S

en

s

or

M

a

in

Circ

u

it

(

%

)

100                                 0

Detection

o

b

ject

Proximity 

s

witch

Non-

s

en

s

ing

 zone

S

en

s

ing

 zone

R

a

ted

detection

di

s

t

a

nce

ON

OFF

ON

OFF

Oper

a

tion

indic

a

tor

(yellow)

O

u

tp

u

t

control

Model

Event

M8

M12

M18

M30

Shielded

l

0

d

8

12

18

30

D

0

m

4.5

8

20

40

n

12

18

27

45

Unshielded

l

6

15

22

30

d

24

40

55

90

D

6

15

22

30

m

8

20

40

70

n

34

36

54

90

(Unit:mm)

Model

Event

M8

M12

M18

M30

Shielded

A

20

30(20)

50(30)

100(50)

B

15

20(12)

35(18)

70(35)

Unshielded

A

80

120(60)

200(100)

300(100)

B

60

100(50)

110(60)

200(100)

(Unit:mm)

Summary of Contents for E2AG

Page 1: ...sing distance Output Type Operation mode NO Operation mode NC Shielded M8 PNP E2AG S08KS01 WP B1 E2AG S08KS01 WP B2 M12 E2AG M12KS02 WP B1 E2AG M12KS02 WP B2 M18 E2AG M18KS05 WS B1 E2AG M18KS05 WS B2...

Page 2: ...mm 6 Kind of connection WP pre wired PVC dia 4 mm WS pre wired PVC dia 6 mm 7 Power Source and Output B DC 3 wire PNP open collector 8 Operation mode 1 Normally open NO 2 Normally closed NC 9 Cable l...

Page 3: ...le p p 10 max 10 30 VDC Current consumption 13 mA max Control output Load current open collector 200 mA max Residual voltage 2 V max under load current of 200 mA with cable length of 2 m Indicator Ope...

Page 4: ...10 C B E2AG M18KS05 C B E2AG M12KS02 C B E2AG S08KS01 C B Distance X mm Distance Y mm E2AG M30KN18 C B E2AG S08KN02 C B E2AG M12KN05 C B E2AG M18KN10 C B Distance X mm Distance Y mm E2AG S08KS01 C B D...

Page 5: ...g object d mm Iron Iron Stainless steel Stainless steel Brass Brass Aluminum Aluminum Copper Distance X mm Distance X mm Iron Stainless steel Aluminum E2AG M18KN10 C B E2AG M30KN18 C B Side length of...

Page 6: ...VC round insulated cable 3 wire dia 4 cross section of conductor 0 3mm insulator diameter 1 3mm standard 2m cable indicator 1 2 clamping nuts toothed washer 1 PVC round insulated cable 3 wire dia 4 cr...

Page 7: ...e Incorrect connection Ensure that the power suppy polarity and other wiring is correct oth erwise incorrect wiring may cause explosion or burning Output Model Operation mode Timing chart Output circu...

Page 8: ...8 Cylindrical Proximity Sensor In the interest of product improvement specifications are subject to change without notice Cat No E61E EN 01...

Reviews: