background image

DRT1-DA02

DRT1-DA02

117

Precautions

Refer to the

DeviceNet Operation Manual (W267)

before using the

Module.

·

To prevent inductive noise, do not wire power lines or

high-tension lines along with or near the cables. Other

noise-prevention techniques, such as using shielding or

separate conduit/ducting, are also effective.

·

Install the Module as far as possible from equipment that

generates strong high-frequency signals (such as high-fre-

quency welders) and equipment that generates surges. Such

equipment can cause the Module to malfunction.

·

Install surge absorbers or noise filters on nearby equipment that

generates noise, particularly equipment that has inductive

components such as motors, transformers, solenoids, or

magnetic coils.

·

When using a noise filter in the power supply, check the voltage

and current and install the noise filter as close as possible to the

Module.

Cat. No.

 P10FAX1A 6/00

 Specifications subject to change without notice. Printed in U.S.A.

OMRON ELECTRONICS, INC.

One East Commerce Drive

Schaumburg, IL 60173

NOTE: DIMENSIONS SHOWN ARE IN MILLIMETERS. To convert millimeters to inches divide by 25.4.

1-800-55-OMRON

OMRON CANADA, INC.

885 Milner Avenue

Scarborough, Ontario M1B 5V8

416-286-6465

R

Summary of Contents for DRT1-DA02

Page 1: ... Specifications Ratings Output Item Type Voltage output Current output Output points 2 points Output type 1 to 5 V 0 to 10 V 10 to 10 V 0 to 20 mA 4 to 20 mA Allowable external output load resistance 1 KW min 600 W max External output impedance 0 5 W max Resolution 1 6000 full scale Overall accuracy 25 C 0 4 full scale 0 C to 55 C 0 8 full scale Conversion time 4 ms 2 points Converted output data ...

Page 2: ... DIN track mounting Mounting strength No damage when 50 N approx 5 kgf pull load was applied for 10 s in all directions 10 N min approx 1 kgf in the DIN track direction Terminal strength No damage when 50 N approx 5 kgf pull load was applied for 10 s in all directions Ambient temperature Operating 0 C to 55 C with no icing or condensation Storage 25 C to 65 C with no icing or condensation Ambient ...

Page 3: ...1 DA02 73 max 150 max 50 max 40 max Mounting Holes Two 4 2 dia or M4 Wiring DRT1 DA02 SOURCE 24 VDC Voltage output connection External device External device Current output connection Internal circuit power supply Internal circuit power supply Terminal Arrangement DRT1 DA02 24 VDC 24 VDC 0 0 0 1 1 1 ...

Page 4: ...n cause the Module to malfunction Install surge absorbers or noise filters on nearby equipment that generates noise particularly equipment that has inductive components such as motors transformers solenoids or magnetic coils When using a noise filter in the power supply check the voltage and current and install the noise filter as close as possible to the Module Cat No P10FAX1A 6 00 Specifications...