D6F-series MEMS Flaw Sensor User’s Manual (A286)
10
6.2 Port style and installation method
6.2.1 Screw type
Please refer to each product datasheet about the types of screw and the tightening torque.
Be sure to design the airproof structure by using a seal tape. When installing this type, the
specified taper thread for piping should be used. In addition, please set to 5N
・
m or less of
the tightening torque. If the tightening torque goes beyond the limit, there is risk that the
sensor will crack and/or gas leakage occurs. Please put an appropriate amount of sealant
on the screw. Do not paint a sealant on two screw threads from the tip of the screw.
6.2.2 Quick fastener type
A quick fastener type for connecting a pipe with a flange is available. The quick fastener
type can be attached and detached by hand (no tools necessary). Currently, there are two
kinds of quick fastener types that have P14 and P10 shape. Below shows the outline
dimensions of quick fastener type of P14 and P10. Please refer to the respective product
datasheet to determine which type of quick fastener is recommended.
Fig.9
Quick fastener P10 Outline Dimensions
Fig.10 Quick fastener P14 Outline Dimensions
<List of quick fastener type in Omron >
D6F-
□A7
:
Quick fastener type
P10
D6F-
□N7
:
Quick fastener type
P10
D6F-
□L7
:
Quick fastener type
P10
D6F-
□AB71
:
Quick fastener type
P14