background image

Read and Understand This Catalog 

Please read and understand this catalog before purchasing the products. Please consult your OMRON representative if you have any questions or 
comments. 
 

Warranty and Limitations of Liability 

 
WARRANTY 

OMRON's exclusive warranty is that the products are free from defects in materials and workmanship for a period of one year (or other period if specified) 
from date of sale by OMRON. 
 
OMRON MAKES NO WARRANTY OR REPRESENTATION, EXPRESS OR IMPLIED, REGARDING NON-INFRINGEMENT, MERCHANTABILITY, OR 
FITNESS FOR PARTICULAR PURPOSE OF THE PRODUCTS.    ANY BUYER OR USER ACKNOWLEDGES THAT THE BUYER OR USER ALONE HAS 
DETERMINED THAT THE PRODUCTS WILL SUITABLY MEET THE REQUIREMENTS OF THEIR INTENDED USE.    OMRON DISCLAIMS ALL OTHER 
WARRANTIES, EXPRESS OR IMPLIED. 

 

LIMITATIONS OF LIABILITY 

OMRON SHALL NOT BE RESPONSIBLE FOR SPECIAL, INDIRECT, OR CONSEQUENTIAL DAMAGES, LOSS OF PROFITS OR COMMERCIAL LOSS 
IN ANY WAY CONNECTED WITH THE PRODUCTS, WHETHER SUCH CLAIM IS BASED ON CONTRACT, WARRANTY, NEGLIGENCE, OR STRICT 
LIABILITY. 
 
In no event shall the responsibility of OMRON for any act exceed the individual price of the product on which liability is asserted. 
 
IN NO EVENT SHALL OMRON BE RESPONSIBLE FOR WARRANTY, REPAIR, OR OTHER CLAIMS REGARDING THE PRODUCTS UNLESS 
OMRON'S ANALYSIS CONFIRMS THAT THE PRODUCTS WERE PROPERLY HANDLED, STORED, INSTALLED, AND MAINTAINED AND NOT 
SUBJECT TO CONTAMINATION, ABUSE, MISUSE, OR INAPPROPRIATE MODIFICATION OR REPAIR. 

 

 

Application Considerations 

 
SUITABILITY FOR USE 

OMRON shall not be responsible for conformity with any standards, codes, or regulations that apply to the combination of products in the customer's 
application or use of the products.   
     
At the customer's request, OMRON will provide applicable third party certification documents identifying ratings and limitations of use that apply to the 
products.    This information by itself is not sufficient for a complete determination of the suitability of the products in combination with the end product, 
machine, system, or other application or use. 
 
The following are some examples of applications for which particular attention must be given.    This is not intended to be an exhaustive list of all possible 
uses of the products, nor is it intended to imply that the uses listed may be suitable for the products: 
 

  Outdoor use, uses involving potential chemical contamination or electrical interference, or conditions or uses not described in this catalog. 

 

  Nuclear energy control systems, combustion systems, railroad systems, aviation systems, medical equipment, amusement machines, vehicles, 

safety equipment, and installations subject to separate industry or government regulations. 

 

  Systems, machines, and equipment that could present a risk to life or property.     

 
Please know and observe all prohibitions of use applicable to the products. 
 
NEVER USE THE PRODUCTS FOR AN APPLICATION INVOLVING SERIOUS RISK TO LIFE OR PROPERTY WITHOUT ENSURING THAT THE 
SYSTEM AS A WHOLE HAS BEEN DESIGNED TO ADDRESS THE RISKS, AND THAT THE OMRON PRODUCTS ARE PROPERLY RATED AND 
INSTALLED FOR THE INTENDED USE WITHIN THE OVERALL EQUIPMENT OR SYSTEM. 

 

PROGRAMMABLE PRODUCTS 

OMRON shall not be responsible for the user's programming of a programmable product, or any consequence thereof. 

 

 

Disclaimers 

 
CHANGE IN SPECIFICATIONS 

Product specifications and accessories may be changed at any time based on improvements and other reasons. 
 
It is our practice to change model numbers when published ratings or features are changed, or when significant construction changes are made.   
However, some specifications of the products may be changed without any notice.    When in doubt, special model numbers may be assigned to fix or 
establish key specifications for your application on your request.    Please consult with your OMRON representative at any time to confirm actual 
specifications of purchased products. 
 

DIMENSIONS AND WEIGHTS 

Dimensions and weights are nominal and are not to be used for manufacturing purposes, even when tolerances are shown. 

 

PERFORMANCE DATA 

Performance data given in this catalog is provided as a guide for the user in determining suitability and does not constitute a warranty. It may represent the 

result of OMRON’s test conditions, and the users must correlate it to actual application requirements. 

Actual performance is subject to the OMRON 

Warranty and Limitations of Liability. 

 

ERRORS AND OMISSIONS 

The information in this document has been carefully checked and is believed to be accurate; however, no responsibility is assumed for clerical, 
typographical, or proofreading errors, or omissions. 

 

 

 

2013.1 

In the interest of product improvement, specifications are subject to change without notice. 

OMRON Corporation 

Industrial Automation Company 

 

http://www.ia.omron.com/ 

(c)Copyright OMRON Corporation 2013 All Right Reserved. 

Summary of Contents for D5C Series

Page 1: ...ting Free attachment to enable changing the antenna shape according to the application Malfunction may occur if used in locations subject to water or oil Be sure to read Safety Precautions on page 6 t...

Page 2: ...0 Hz Sensitivity setting range 30 to 100 pF Current consumption 17 mA max Leakage current Circuit 2 mA max Antenna 1 mA max 1 mA max Response time 2 ms max 8 ms max Output current 200 mA max resistive...

Page 3: ...ity Temperature C Sensitivity pF 10 20 30 200 150 100 50 0 With sensitivity adjuster set to minimum sensitivity With sensitivity adjuster set to maximum sensitivity Voltage V Sensitivity pF 200 300 10...

Page 4: ...ction However limit the overtravel to within 20 mm from the free position The force that pushes the actuator must not exceed 1 96 N 2 Vinyl insulated round cable oil and shock resistant type 4 dia thr...

Page 5: ...6 N 2 Vinyl insulated round cable oil and shock resistant type 4 dia three conductors 0 3 mm2 3 Use after removing the caution label Coil Spring D5C 1AS0 2 1 LED Operation indicator M18 1 Two internal...

Page 6: ...nded provided that the total length of the antenna is 1 m maximum Fig 2 and that the bottom of the antenna is at least 10 cm Fig 3 away from the ground Refer to the illustrations below The D5C may be...

Page 7: ...er supply of the PC Programmable Controller is not available to the D5C 1D 0 The negative line of the service power supply of the PC is not grounded Therefore the D5C may not operate Furthermore if th...

Page 8: ...products Outdoor use uses involving potential chemical contamination or electrical interference or conditions or uses not described in this catalog Nuclear energy control systems combustion systems r...