background image

2

D5C

Ordering Information

Note: The lead wire is 3 m.

Specifications

Ratings and Characteristics

Features

·Usable by bending tip of antenna.
·Overtravel of 20 mm max.

·Ideal for high-accuracy position control.
·Overtravel of 3.5 mm max.

·Any actuator can be attached.

Actuator

Coil spring

Plunger

Free-attachment

Item

Model

Model

Model

Supply voltage 
(Power supply)

DC

D5C-1DS0

D5C-1DP0

D5C-1DA0

AC

D5C-1AS0

D5C-1AP0

D5C-1AA0

Antenna only

D5C-00S0

D5C-00P0

D5C-00A0

Type

DC

AC

Item

Model

D5C-1D

@

0

D5C-1A

@

0

Degree of protection

Equivalent to IP67

Mechanical durability

10,000,000 operations min. (at rated overtravel value)

Supply voltage (operating voltage)

12 to 24 VDC (10 to 30 VDC), (ripple: 10% max.)

100 to 240 VAC (45 to 264 VAC), 50/60 Hz

Rated frequency

---

50/60 Hz

Sensitivity setting range

30 to 100 pF

Current consumption

17 mA max.

---

Leakage current

Circuit

---

2 mA max.

Antenna

1 mA max.

1 mA max.

Response time

2 ms max.

8 ms max.

Output current

200 mA max. (resistive load)

Insulation resistance

50 M

Ω

 min. (at 500 VDC) between lead wires and case

Dielectric strength

1,000 VAC, 50/60 Hz for 1 min between current-carry-
ing metal parts and non-current-carrying metal parts

2,000 VAC, 50/60 Hz for 1 min between current-carry-
ing metal parts and non-current-carrying metal parts

Rated insulation voltage (Ui)

1,000 VAC

Pollution degree
(operating environment)

3 (IEC947-5-1)

Protection against electric shock

Class II

Proof tracking index (PTI)

175

Switch category

D (IEC335)

Vibration resistance

10 to 55 Hz, 1.5-mm double amplitude

Shock resistance

1,000 m/s

2

 max.

Ambient temperature

Operating: 

25

°

C to +70

°

C (with no icing)

Ambient humidity

35% to 95%RH

Weight

Approx. 110 g (in case of D5C-1DS0)

Approx. 120 g (in case of D5C-1AS0)

Summary of Contents for D5C Series

Page 1: ...ting Free attachment to enable changing the antenna shape according to the application Malfunction may occur if used in locations subject to water or oil Be sure to read Safety Precautions on page 6 t...

Page 2: ...0 Hz Sensitivity setting range 30 to 100 pF Current consumption 17 mA max Leakage current Circuit 2 mA max Antenna 1 mA max 1 mA max Response time 2 ms max 8 ms max Output current 200 mA max resistive...

Page 3: ...ity Temperature C Sensitivity pF 10 20 30 200 150 100 50 0 With sensitivity adjuster set to minimum sensitivity With sensitivity adjuster set to maximum sensitivity Voltage V Sensitivity pF 200 300 10...

Page 4: ...ction However limit the overtravel to within 20 mm from the free position The force that pushes the actuator must not exceed 1 96 N 2 Vinyl insulated round cable oil and shock resistant type 4 dia thr...

Page 5: ...6 N 2 Vinyl insulated round cable oil and shock resistant type 4 dia three conductors 0 3 mm2 3 Use after removing the caution label Coil Spring D5C 1AS0 2 1 LED Operation indicator M18 1 Two internal...

Page 6: ...nded provided that the total length of the antenna is 1 m maximum Fig 2 and that the bottom of the antenna is at least 10 cm Fig 3 away from the ground Refer to the illustrations below The D5C may be...

Page 7: ...er supply of the PC Programmable Controller is not available to the D5C 1D 0 The negative line of the service power supply of the PC is not grounded Therefore the D5C may not operate Furthermore if th...

Page 8: ...products Outdoor use uses involving potential chemical contamination or electrical interference or conditions or uses not described in this catalog Nuclear energy control systems combustion systems r...

Reviews: