2
D5C
Ordering Information
Note: The lead wire is 3 m.
Specifications
Ratings and Characteristics
Features
·Usable by bending tip of antenna.
·Overtravel of 20 mm max.
·Ideal for high-accuracy position control.
·Overtravel of 3.5 mm max.
·Any actuator can be attached.
Actuator
Coil spring
Plunger
Free-attachment
Item
Model
Model
Model
Supply voltage
(Power supply)
DC
D5C-1DS0
D5C-1DP0
D5C-1DA0
AC
D5C-1AS0
D5C-1AP0
D5C-1AA0
Antenna only
D5C-00S0
D5C-00P0
D5C-00A0
Type
DC
AC
Item
Model
D5C-1D
@
0
D5C-1A
@
0
Degree of protection
Equivalent to IP67
Mechanical durability
10,000,000 operations min. (at rated overtravel value)
Supply voltage (operating voltage)
12 to 24 VDC (10 to 30 VDC), (ripple: 10% max.)
100 to 240 VAC (45 to 264 VAC), 50/60 Hz
Rated frequency
---
50/60 Hz
Sensitivity setting range
30 to 100 pF
Current consumption
17 mA max.
---
Leakage current
Circuit
---
2 mA max.
Antenna
1 mA max.
1 mA max.
Response time
2 ms max.
8 ms max.
Output current
200 mA max. (resistive load)
Insulation resistance
50 M
Ω
min. (at 500 VDC) between lead wires and case
Dielectric strength
1,000 VAC, 50/60 Hz for 1 min between current-carry-
ing metal parts and non-current-carrying metal parts
2,000 VAC, 50/60 Hz for 1 min between current-carry-
ing metal parts and non-current-carrying metal parts
Rated insulation voltage (Ui)
1,000 VAC
Pollution degree
(operating environment)
3 (IEC947-5-1)
Protection against electric shock
Class II
Proof tracking index (PTI)
175
Switch category
D (IEC335)
Vibration resistance
10 to 55 Hz, 1.5-mm double amplitude
Shock resistance
1,000 m/s
2
max.
Ambient temperature
Operating:
−
25
°
C to +70
°
C (with no icing)
Ambient humidity
35% to 95%RH
Weight
Approx. 110 g (in case of D5C-1DS0)
Approx. 120 g (in case of D5C-1AS0)