Guard Lock Safety-door Switch

 D4JL

S

a

fe

ty D

o

o

r

Sw

it

c

h

e

s

P

recau

ti

on
s f
o

r

All Sa

fe

ty

 Do

o

r

Switch

e

s

D4
NS

D4
GS-

N

D

4

BS

D4
G

L

D4
JL

D

4

NL

D4
BL

D4
NH

D

4

0

B

D4
NS-

SK0

1

D4
NS-

SK3

0

D4
J

L

-SK3

0

56

Specifications

Standards and EC Directives

Conforms to the following EC 
Directives

• Machinery Directive

• Low Voltage Directive

• EN 1088
• EN 60204-1

• GS-ET-19

• CCC (Application scheduled)

Certified Standards

Note: CSA C22.2 No. 14 was certified by UL.

Certified Standard Ratings

TÜV (EN 60947-5-1)

Note: Use a 10-A fuse type g

I

 or g

G

 that conforms to IEC 60269 as a 

short-circuit protection device. This fuse is not built into the 
Switch.

UL/CSA (UL 508, CSA C22.2 No. 14)

A300

Solenoid Coil Characteristics

Indicator Characteristics

Characteristics

Note: 1. The above values are initial values.

2. The degree of protection is tested using the method specified by 

the standard (EN 60947-5-1). Confirm that sealing properties 
are sufficient for the operating conditions and environment 
beforehand. Although the switch box is protected from dust or 
water penetration, do not use the D4JL in places where foreign 
material may enter through the key hole on the head, otherwise 
Switch damage or malfunctioning may occur.

3. The durability is for an ambient temperature of 5 to 35°C and an 

ambient humidity of 40% to 70%. For further conditions, consult 
your OMRON sales representative.

4. Do not pass a 3-A, 250-VAC load through more than two 

circuits.

5. These figures are minimum requirements for safe operation.
6. This figure is based on the GS-ET-19 evaluation method.
7. This value will vary with the switching frequency, environment, 

and reliability level. Confirm that correct operation is possible 
with the actual load beforehand.

8. Use a 10-A fuse type g

I

 or g

G

 that conforms to IEC 60269 as a 

short-circuit protection device.

Certification 

body

Standard

File No.

TÜV Product 
Service

EN 60947-5-1 
(certified direct opening)

Consult your OMRON 
representative for 
details.

UL (See note.) UL 508, CSA C22.2 No.14 

CQC (CCC)

GB14048.5 

Application scheduled

Item

Utilization

category

AC-15 DC-13 

Rated operating current 
(Ie)

3 A 

0.27 A 

Rated operating voltage 
(Ue)

240 V 

250 V 

Rated 

voltage

Carry 

current

Current (A)

Volt-amperes (VA)

Make

Break

Make

Break

120 VAC

10 A 

60 

7,200 

720 

240 VAC

30 

Item

Type

24 VDC

Rated operating voltage 
(100% ED)

24 VDC 

Current consumption

Approx. 200 mA

Insulation

Class F (130°C max.)

Item

Type

LED

Rated voltage

24 VDC 

24 VDC 

Current consumption

Approx. 1 mA

Approx. 8 mA

Color (LED)

Orange

Green

+10%

15%

Degree of protection 
(See note 2.)

IP67 (EN 60947-5-1)
(This applies for the Switch only. The degree 
of protection for the key hole is IP00.)

Durability 
(See note 
3.)

Mechanical 1,000,000 operations min. (trapped key: 

10,000 operations min., rear release button: 
3,000 operations min.)

Electrical

500,000 operations min. for a resistive load 
of 3 A at 250 VAC (See note 4.)

Operating speed

0.05 to 0.5 m/s

Operating frequency

30 operations/minute max.

Rated frequency

50/60 Hz 

Direct opening force 
(See note 5.)

60 N min. (EN 60947-5-1)

Direct opening travel 
(See note 5.)

15 mm min. (EN 60947-5-1)

Holding force 
 (See note 6.)

3,000 N min.

Insulation resistance

100 M

 min. (at 500 VDC)

Minimum applicable 
load (See note 7.)

Resistive load of 1 mA at 5 VDC (N-level 
reference value)

Rated insulation voltage 
(U

i

)

300 V (EN 60947-5-1)

Rated open thermal 
current (I

th

)

10 A between terminals 12 and 41, 3 A 
between all other terminals (EN 60947-5-1)

Impulse withstand 
voltage 
(EN 60947-5-1)

Between terminals of same polarity

2.5 kV 

Between terminals of different 
polarity

4 kV 

Between other terminals and 
uncharged metallic parts

6 kV 

Conditional short-circuit 
current

100 A (EN 60947-5-1) (See note 8.)

Pollution degree 
(operating environment)

3 (EN 60947-5-1)

Protection against 
electric shock

Class II (double insulation)

Contact resistance 
(initial value)

25 m

 max. per contact

Vibration 
resistance

Malfunction 10 to 55 Hz, 0.75-mm single amplitude

Shock 
resistance

Destruction 1,000 m/s

2

 min.

Malfunction 80 m/s

2

 min.

Ambient operating 
temperature

10 to +55°C (with no icing)

Ambient operating 
humidity

95% max.

Weight

Approx. 650g

Summary of Contents for D4JL-1NFA-C5

Page 1: ...page 55 for a list of models OMRON also offers Trapped Key Switches on mechanical lock models only The door can be opened only by supplying power to the solenoid and then turning the trapped key to un...

Page 2: ...ical lock 24 VDC solenoid release G 24 VDC Solenoid lock Mechanical release 5 Indicator C 24 VDC green LED indicator D 24 VDC orange LED indicator 6 Release Key Type 5 Special release key See note 3 6...

Page 3: ...D4JL 2NFG C5 1 2 14NPT D4JL 3NFG C5 M20 D4JL 4NFG C5 2NC 1NO 3NC PG13 5 D4JL 1PFG C5 G1 2 D4JL 2PFG C5 1 2 14NPT D4JL 3PFG C5 M20 D4JL 4PFG C5 3NC 2NC 1NO PG13 5 D4JL 1QFG C5 G1 2 D4JL 2QFG C5 1 2 14N...

Page 4: ...FA C6 1 2 14NPT D4JL 3NFA C6 M20 D4JL 4NFA C6 2NC 1NO 3NC PG13 5 D4JL 1PFA C6 G1 2 D4JL 2PFA C6 1 2 14NPT D4JL 3PFA C6 M20 D4JL 4PFA C6 3NC 2NC 1NO PG13 5 D4JL 1QFA C6 G1 2 D4JL 2QFA C6 1 2 14NPT D4JL...

Page 5: ...A C7 01 G1 2 D4JL 2PFA C7 01 1 2 14NPT D4JL 3PFA C7 01 M20 D4JL 4PFA C7 01 3NC 2NC 1NO PG13 5 D4JL 1QFA C7 01 G1 2 D4JL 2QFA C7 01 1 2 14NPT D4JL 3QFA C7 01 M20 D4JL 4QFA C7 01 3NC 3NC PG13 5 D4JL 1RF...

Page 6: ...ils UL See note UL 508 CSA C22 2 No 14 CQC CCC GB14048 5 Application scheduled Item Utilization category AC 15 DC 13 Rated operating current Ie 3 A 0 27 A Rated operating voltage Ue 240 V 250 V Rated...

Page 7: ...tacts door open closed detection and lock monitor Contact forms Operating pattern Remarks Lock monitor Door open closed detection D4JL NF 2NC 1NO 2NC 1NO NC contacts 11 12 and 21 22 have a certified d...

Page 8: ...is supplied to the solenoid The door is unlocked manually E1 E2 Solenoid ON 41 12 NC 51 22 NC Door open closed detection and lock monitor contacts 31 32 NC Door open closed detection contact 33 34 NO...

Page 9: ...ase button Terminal No and function Door open The door will lock when the door closes Door closed The door is locked Door open The door can be opened Door closed No power is supplied to the solenoid T...

Page 10: ...he Key is not inserted The door will not lock when the door closes Door closed The Key is not inserted The door is not locked Door closed The Key is inserted The door is locked Door closed The Key is...

Page 11: ...ples Mechanical Lock Models Solenoid Lock Models Operation Key removed Operation Key inserted Door locked Solenoid ON Door unlocked B B OFF Cross sectional view B B Cross sectional view B B B B OFF Cr...

Page 12: ...Key inserted solenoid OFF and trapped key inserted Status Door locked and trapped key cannot be removed Cross sectional view B B OFF B B Cross sectional view B B OFF B B Cross sectional view B B OFF B...

Page 13: ...L F D5 Operating characteristics Model D4JL F C5 D4JL F D5 Key insertion force Key extraction force 20 N max Approx 6 N Pre travel distance 14 mm max Movement before being locked 3 3 mm min Black Red...

Page 14: ...6 21 B B Cross sectional view B B Cross sectional view A A Cap screw Conduit cap 2 conduits A A Four 5 4 dia holes Trapped key Manual release screw Head cap Six cover mounting screws 5 2 10 0 40 51 1...

Page 15: ...tolerance of key hole 0 8 22 Black Red Black Red 22 51 7 5 Horizontal insertion radius R 270 Vertical insertion radius R 270 Center tolerance of key hole 0 8 Center tolerance of key hole 0 8 Operatio...

Page 16: ...4 KM1 KM2 KM1 KM2 M 44 54 62 K2 K2 6 K3 1 a b OffDelay Timer Control Circuit K4 a b Operation instruction Feedback loop KM1 KM2 S3 Motor controller S1 Safety door Switch with direct opening contact S2...

Page 17: ...34 M2 KM4 KM3 Motor controller 51 52 21 22 51 52 21 22 Logical AND connection G9SX BC Basic Unit Emergency stop switch Emergency stop switch Safety Door Switch Safety Door Switch Advanced Unit G9SX AD...

Page 18: ...tioning to its full capability Make sure the Switch is mounted securely to prevent it from falling off Otherwise injury may result Mount the Operation Key so that it will not come into contact with pe...

Page 19: ...it to the LOCK setting before resuming operation The release key is set in the unlock position at the factory for the D4JL A 5 and D4JL A 6 and in the lock position for the D4JL G 5 and D4JL A 7 If th...

Page 20: ...er the machine stops operating Mounting Methods Tightening Torque Be sure to tighten each screw of the Switch properly Loose screws may result in malfunction Switch and Operation Key Mounting Mount th...

Page 21: ...to a suitable torque The conduit cap is provided with the Switch Recommended Connectors Use a connector with a screw section not exceeding 9 mm Otherwise the screws will protrude into the case interi...

Page 22: ...d Lock Safety door Switch will heat when power is supplied to the solenoid Do not touch these Switches Perform maintenance inspections periodically In the interest of product improvement specification...

Reviews: