background image

Enclosed Switch

 

D4C

F-9

Lim

it 

Switch

es

Enclosed Switch

D4C

Sealed, Compact, and Slim-bodied Switch 
Offers Choice of Many Actuators

• Liquid- and dust-resistance conforms to IEC IP67 standard.

• Triple-sealed construction:

Plunger section sealed via nitrile rubber packing seal and dia-
phragm; switch section sealed via nitrile rubber cap; cable en-
trance sealed via encapsulating material.

• Standard cable (S-FLEX VCTF) in 2-, 3-, or 5-meter lengths of-

fers high flexibility with outstanding oil and extreme temperature 
resistance.

• Low temperature models are available.

Model Number Structure

Model Number Legend

Standard Models

1. Rated Current

1:

5 A at 250 VAC, 4 A at 30 VDC

2:

5 A at 125 VAC (with LED indicator)

3:

4 A 30 VDC (with LED indicator)

4:

0.1 A at 125 VAC, 0.1 A at 30 VDC

5:

0.1 A at 125 VAC (with LED indicator)

6:

0.1 A at 30 VDC (with LED indicator)

2. Cable Specifications

2:

VCTF oil-resistant cable (3 m)

3:

VCTF oil-resistant cable (5 m)

4:

VCTF (3 m)

5:

VCTF (5 m)

6:

SJT(O) (3 m)

7:

SJT(O) (5 m)

8:

VCTF oil-resistant cable (2 m)

9:

VCTF (2 m)

3. Actuator

01:

Pin plunger

02:

Roller plunger

03:

Crossroller plunger

10:

Bevel plunger

20:

Roller lever

24:

Roller lever (high-sensitivity model)

31:

Sealed pin plunger

32:

Sealed roller plunger

33:

Sealed crossroller

41:

Panel mount pin plunger

42:

Panel mount roller plunger

43:

Panel mount crossroller plunger

50:

Plastic rod

60:

Center roller lever plunger

Note 1:

Some combinations of the above may not be supported.

2:

With standard models, the operation indicator turns OFF
when the switch operates. If models with operation indicators
that turn ON when the switch operates are required, add "-B”
to the end of the model number.

1  2   3

D4C-

@@@

Summary of Contents for D4C -

Page 1: ...indicator 4 0 1 A at 125 VAC 0 1 A at 30 VDC 5 0 1 A at 125 VAC with LED indicator 6 0 1 A at 30 VDC with LED indicator 2 Cable Specifications 2 VCTF oil resistant cable 3 m 3 VCTF oil resistant cable...

Page 2: ...ces 2 conductors NO wiring 4 Cable length 03 0 3 m 05 0 5 m 10 1 m Wiring Specifications Note Since the above wiring specifications are different from those for the D4CC be careful not to mistake them...

Page 3: ...2 D4C 902 D4C 402 D4C 502 D4C 1602 D4C 1702 D4C 2602 D4C 2702 D4C 832 D4C 232 D4C 332 D4C 932 D4C 432 D4C 532 D4C 1632 D4C 1732 D4C 2632 D4C 2732 D4C 803 D4C 203 D4C 303 D4C 903 D4C 403 D4C 503 D4C 16...

Page 4: ...2 M D4C 1G24 3 M D4C 1G24 5 M D4C 1G41 1 M D4C 1G41 2 M D4C 1G41 3 M D4C 1G41 5 M D4C 1G42 1 M D4C 1G42 2 M D4C 1G42 3 M D4C 1G42 5 M D4C 1G43 1 M D4C 1G43 2 M D4C 1G43 3 M D4C 1G43 5 M Actuator 1 A a...

Page 5: ...20 P D4C 6220 P 5 m D4C 1320 P D4C 4320 P D4C 2320 P D4C 3320 P D4C 5320 P D4C 6320 P 3 m D4C 1224 P D4C 4224 P D4C 2224 P D4C 3224 P D4C 5224 P D4C 6224 P 5 m D4C 1324 P D4C 4324 P D4C 2324 P D4C 332...

Page 6: ...voltage Non inductive load Inductive load Inrush current Resistive load Lamp load Inductive load Motor load NC NO NC NO NC NO NC NO NC NO D4C 1 125 VAC 5 A 5 A 1 5 A 0 7 A 3 A 3 A 2 5 A 1 3 A 20 A ma...

Page 7: ...current Resistive load Lamp load Inductive load Motor load NC NO NC NO NC NO NC NO NC NO 125 VAC 1 1 1 0 7 1 1 1 1 20 A max 10 A max 30 VDC 1 1 1 1 1 1 1 1 Rated voltage Carry current Current Volt am...

Page 8: ...47 5 1 Switching overvoltage 1 000 VAC 300 VDC max EN60947 5 1 Pollution degree operating environment 3 IEC60947 5 1 Short circuit protective device SCPD 10 A fuse type gG IEC269 Conditional short cir...

Page 9: ...x 11 77 N 11 77 N 11 77 N 6 67 N RF min 4 41 N 4 41 N 4 41 N 1 47 N PT max 1 8 mm 1 8 mm 1 8 mm 10 3 OT min 3 mm 3 mm 3 mm 50 MD max 0 2 mm 0 2 mm 0 2 mm 3 OP 31 2 1 mm 36 8 1 mm 36 8 mm TT 5 mm 5 mm...

Page 10: ...uator is in the free position the indicator is lit and when the actuator is turned or pushed and the contact comes into contact with the NO side the indicator turns OFF 3 4 2 Without LED Indicator AC...

Page 11: ...1 7 mA 15 k 0 10 50 100 300 500 1 000 3 000 5 000 30 50 100 300 500 1 000 3 000 10 000 5 000 7 000 30 0 20 40 60 80 100 120 1 2 3 4 5 6 7 Operating frequency 30 operations min cos 1 L R 0 Operating te...

Page 12: ...r Setscrew This screw is made of stainless steel and has high corrosion resistance Built in Switch Both standard load and microload models available Rotary Shaft The shaft is made of stainless steel d...

Page 13: ...teel roller Correct setting position 51 5 max 67 max 40 max Rubber cap 49 max 40 max 49 max 54 2 max 40 max Pin Plunger D4C 01 Sealed Plunger D4C 31 Roller Plunger D4C 02 10 dia stainless steel plunge...

Page 14: ...er Plunger D4C 32 Rubber cap 49 max 40 max 12 dia x 5 stainless steel roller 0 Two 5 1 0 2 dia holes Spot facing 10 2 dia Depth 6 VCTF cable 0 75 mm2 4 conductor Finishing O D 7 6 12 dia x 5 stainless...

Page 15: ...0 2 dia holes Spot facing 10 2 dia Depth 6 Correct setting position VCTF cable 0 75 mm2 4 conductor Finishing O D 7 6 Note 1 Operation is possible in any direction except in par allel to the axis 2 Th...

Page 16: ...ess sintered roller M5 length 12 Allen head bolt 0 Two 5 1 0 2 dia holes Spot facing 10 2 dia Depth 6 VCTF cable 0 75 mm2 4 conductor Finishing O D 7 6 see note Note S FLEX VCTF Cables are used for we...

Page 17: ...t Pin Plunger D4C 41 Panel Mount Roller Plunger D4C 42 Panel Mount Crossroller Plunger D4C 43 49 max 40 max 10 dia stainless steel plunger 0 Two 5 1 0 2 dia holes Spot facing 10 2 dia Depth 6 Correct...

Page 18: ...Sealed Roller Plunger Sealed Pin Plunger D4C 001 K1EJ D4C 001 M1J D4C 002 K1EJ D4C 002 M1J D4C 031 K1EJ D4C 031 M1J D4C 032 K1EJ D4C 032 M1J 0 Two 5 1 0 2 dia holes Spot facing 10 2 dia Depth 6 Corre...

Page 19: ...ng 10 2 dia Depth 6 Adjustable Roller Lever D4C 27 P Adjustable Rod Lever D4C 29 P 40 max 30R to 75R variable 40 max 65 max 65 max 57 7 max 55 max 17 5 dia x 7 stainless steel roller M5 length 16 Alle...

Page 20: ...lts and two M5 x 0 8 Allen head bolts are provided 0 Note 1 Tighten the 5 2 0 2 dia holes with the M5 x 10 hexagon pan head screws 2 Insert the M5 Allen head bolts into the M5 tapping holes to tighten...

Page 21: ...imit Switch for the EN ratings use the gI or gG 10 A fuse Operation Operation method shapes of cam and dog operating frequency and overtravel have a significant effect on the service life and precisio...

Page 22: ...Tighten each screw to a torque according to the following table Note By removing the two screws from the head the head direction can be rotated 180 After changing the head direction re tight en to th...

Reviews: