Precautions

Do not dismount the Operation Key from the door intentionally and
insert it to the Switch with the door open. Machine may start oper-
ating and injury or death may be caused.

Mount the Operation Key at a location where it will not come in con-
tact with users when the door is opened or closed.

When operating the D4BS as a part of a safety category circuit to
prevent injury, operate the NC contacts that have a direct opening
mechanism in direct opening mode. For safety purposes, tighten the
switch body and Operation Key with one-way screws or equivalents
or install a switch protection cover and warning label for safety pur-
poses to prevent easy removal of the D4BS.

Connect the fuse to the D4BS in series to prevent it from short-circuit
damage. The value of the breaking current of the fuse must be calcu-
lated by multiplying rated current by 150% to 200%. When using the
D4BS with EN ratings, use 10-A fuse Type gI or gG that complies
with IEC60269.

Correct Use

Operating Environment

Make sure in advance that the environment is suitable, with no oil,
water, or chemicals, as these may cause the seal to deteriorate,
resulting in faulty contact, faulty isolation, current leakage, or burn-
ing.

Do not use the D4BS in the following locations:

Locations subject to severe temperature changes

Locations subject to high temperatures or condensation

Locations subject to severe vibration

Locations where the product may come into direct contact with pro-
cessing waste or dust

Operation Key

Be sure to use a special Operation Key only. Do not operate the
D4BS with anything other than the special Operation Key, otherwise
the D4BS may break or the safety of the system may not be main-
tained.

Do not impose excessive force on the Operation Key inserted into
the D4BS or drop the D4BS with the Operation Key inserted, other-
wise the Operation Key may deform or break.

Secure the Operation Key with a one-way screw, or an equivalent, so
that the Operation Key cannot be easily removed.

Securing the Door

If the Operation Key on the closed door is pulled outside the set zone
by a force caused by vibration, the door’s weight, or the door cushion
rubber, the switch contact may be opened (causing the machinery to
stop) or the D4BS may be damaged. Secure the door with hooks so
that it will remain within the set zone.

Mounting

Do not use the Switch as a stopper. Be sure to install a stopper as
shown in the following illustration when mounting the Switch. The
range of space “a” must be determined according to the available set
zone of the Operation Key.

Refer to 

Dimensions

 for the mounting dimension of the Operation

Key and mount the Operation Key correctly. The Operation Key will
soon become damaged or worn out if it is not mounted correctly.

Make sure that the Operation Key can be inserted properly with a tol-
erance of 

±

0.5 mm in the upward, downward, left, or right direction,

otherwise the D4BS may soon become damaged.

Excessive force

Drop

Extra space

Set zone

a

Stopper

Switch

±

0.5 min.

±

0.5 min.

F502-EN2-04.book  Seite 149  Dienstag, 26. Juli 2005  5:48 17

Summary of Contents for D4BS -

Page 1: ...odel Number Legend Ordering Information List of Models Switches Prefered stock item Type Mounting direction Conduit size 1NC 1NO Slow action 2NC Slow action 1 conduit Front side mounting Pg13 5 D4BS 1...

Page 2: ...e UL CSA UL508 CSA C22 2 No 14 A600 Type Model D4BS K1 D4BS K2 D4BS K3 Horizontal mounting Vertical mounting Adjustable mounting Horizontal Agency Standard File No T V Rheinland EN60947 5 1 UL UL508 E...

Page 3: ...and ground and between each ter minal and non current carrying metal part Contact resistance 25 m max initial value Rated insulation voltage Ui 600 V EN60947 5 1 Conventional enclosed thermal current...

Page 4: ...contacts from each other by using shearing force if any abnormality such as contact welding should occur in the contact area There is a difference in level between the NC and NO terminal which assures...

Page 5: ...amping screws Six 5 3 dia mounting holes Four M3 5 x 10 cover clamping screws D4BS 1 S Pg13 5 D4BS 2 S G1 2 D4BS 4 S 1 2 14NPT D4BS 5 S 3 Pg13 5 D4BS 6 S 3 G1 2 D4BS 8 S 3 1 2 14NPT 30 0 2 19 61 N max...

Page 6: ...Key insertion radius in horizontal direction R 1200 53 5 min 58 max Operation Key insertion radius in horizontal direction R 1000 D4BS 1 S D4BS K2 D4BS 2 S D4BS K2 D4BS 4 S D4BS K2 54 5 min 59 max Ope...

Page 7: ...on Locations where the product may come into direct contact with pro cessing waste or dust Operation Key Be sure to use a special Operation Key only Do not operate the D4BS with anything other than th...

Page 8: ...d Mounting Direction By removing the screws on the four corners of the head the head can be reset in any of four directions The head direction can be changed with or without the Operation Key inserted...

Page 9: ...ing so that the enclosure will confirm to IP67 If using a Pg13 5 conduit use an ABS 08 Pg13 5 connector or an ABS 12 Pg13 5 connector manufactured by Nippon Flex Use a connector SC Series sold separat...

Page 10: ...est of product improvement specifications are subject to change without notice ALL DIMENSIONS SHOWN ARE IN MILLIMETERS To convert millimeters into inches multiply by 0 03937 To convert grams into ounc...

Reviews: