background image

G-144

Safety Sensors / Components

Operation Keys (Order Separately)

Specifications

Approved Standards

Standards and EC Directives

Conforms to the following EC Directives:
Machinery Directive
Low Voltage Directive
EN50041
EN1088

Approved Standard Ratings

TÜV (EN60947-5-1)

Note:

Use a 10-A fuse type a gI or gG that conforms to IEC269 as a short-circuit protection device.

UL/CSA (UL508, CSA C22.2 No. 14)

A600

Type

Model

D4BS-K1

D4BS-K2

D4BS-K3

Horizontal mounting

Vertical mounting

Adjustable mounting 
(Horizontal)

Agency

Standard

File No.

TÜV Rheinland

EN60947-5-1

UL

UL508

E76675

CSA

CSA C22.2 No. 14

LR45746

BIA

GS-ET-15

9303323

SUVA

SUVA

E6187.d

R9351022  
(Direct open-
ing: approved)

Utilization category

AC-15

Rated operating current (Ie)

2 A

Rated operating voltage (Ue)

400 V

Rated voltage

Carry current

Current

Volt-amperes

Make

Break

Make

Break

120 VAC

10 A

60 A

6 A

7,200 VA

720 VA

240 VAC

30 A

3 A

480 VAC

15 A

1.5 A

600 VAC

12 A

1.2 A

F502-EN2-04.book  Seite 144  Dienstag, 26. Juli 2005  5:48 17

Summary of Contents for D4BS -

Page 1: ...odel Number Legend Ordering Information List of Models Switches Prefered stock item Type Mounting direction Conduit size 1NC 1NO Slow action 2NC Slow action 1 conduit Front side mounting Pg13 5 D4BS 1...

Page 2: ...e UL CSA UL508 CSA C22 2 No 14 A600 Type Model D4BS K1 D4BS K2 D4BS K3 Horizontal mounting Vertical mounting Adjustable mounting Horizontal Agency Standard File No T V Rheinland EN60947 5 1 UL UL508 E...

Page 3: ...and ground and between each ter minal and non current carrying metal part Contact resistance 25 m max initial value Rated insulation voltage Ui 600 V EN60947 5 1 Conventional enclosed thermal current...

Page 4: ...contacts from each other by using shearing force if any abnormality such as contact welding should occur in the contact area There is a difference in level between the NC and NO terminal which assures...

Page 5: ...amping screws Six 5 3 dia mounting holes Four M3 5 x 10 cover clamping screws D4BS 1 S Pg13 5 D4BS 2 S G1 2 D4BS 4 S 1 2 14NPT D4BS 5 S 3 Pg13 5 D4BS 6 S 3 G1 2 D4BS 8 S 3 1 2 14NPT 30 0 2 19 61 N max...

Page 6: ...Key insertion radius in horizontal direction R 1200 53 5 min 58 max Operation Key insertion radius in horizontal direction R 1000 D4BS 1 S D4BS K2 D4BS 2 S D4BS K2 D4BS 4 S D4BS K2 54 5 min 59 max Ope...

Page 7: ...on Locations where the product may come into direct contact with pro cessing waste or dust Operation Key Be sure to use a special Operation Key only Do not operate the D4BS with anything other than th...

Page 8: ...d Mounting Direction By removing the screws on the four corners of the head the head can be reset in any of four directions The head direction can be changed with or without the Operation Key inserted...

Page 9: ...ing so that the enclosure will confirm to IP67 If using a Pg13 5 conduit use an ABS 08 Pg13 5 connector or an ABS 12 Pg13 5 connector manufactured by Nippon Flex Use a connector SC Series sold separat...

Page 10: ...est of product improvement specifications are subject to change without notice ALL DIMENSIONS SHOWN ARE IN MILLIMETERS To convert millimeters into inches multiply by 0 03937 To convert grams into ounc...

Reviews: