CHARACTERISTICS
Degree of protection
IP67 (See note 2.)
Life expectancy (See note 3.)
Mechanical: 1,000,000 operations min.
Electrical: 500,000 operations min.
Operating speed
0.05 to 0.5 m/s
Operating frequency
30 operations/min max.
Rated frequency
50/60 Hz
Operating characteristics
Positive opening force: 19.61 N min. (EN60947-5-1)
Positive opening stroke: 20 mm min. (EN60947-5-1)
All stroke:23 mm min.
Locked resistive pulling force
700 N min. (GS-ET-19)
Insulation resistance
100 M
Ω
min. (at 500 VDC)
Rated insulation voltage (U
i
)
300 VAC (EN60947-5-1)
Conventional enclosed thermal
current (I
the
) (rated continuous
current)
10 A (EN60947-5-1)
Dielectric strength (U
imp
)
Impulse dielectric strength (U
imp
) 4 kV (EN60947-5-1) between terminals of different polarity,
between each terminal and ground, and between each terminal and non-current-carrying metal
part;
2.5 kV between solenoid and ground
Conditional short-circuit current
100 A (EN60947-5-1)
Operating environmental pollution
level
Pollution degree 3 (EN60947-5-1)
Electric shock protection class
Class I (with grounded terminal)
Counter electromotive voltage at
switching
1,500 V max. (EN60947-5-1)
Contact resistance
50 m
Ω
max. (initial value)
Vibration resistance
Malfunction: 10 to 55 Hz, 0.35-mm single amplitude with an imposed acceleration of 50 m/s
2
max. (IEC68-2-6)
Shock resistance
Destruction: 1,000 m/s
2
min. (IEC68-2-27)
Malfunction: 300 m/s
2
min. (IEC68-2-27)
Ambient temperature
Operating: --10
°
C to 55
°
C (with no icing)
Ambient humidity
Operating: 95% max.
Weight
Approx. 800 g
Note: 1. The values provided in the above table are the initial values.
2. Although the switch box does not allow the penetration of dust, oil or water, avoid as much as possible the penetration of dust,
oil, or water into the head’s Operation Key insertion slot.
3. The life expectancy is for an ambient temperature of 5
°
C to 35
°
C and ambient humidity of 40% to 70%. For further conditions,
consult your OMRON sales representative.
Solenoid Coil Characteristics
Item
24-VDC Mechanical lock models
110-VAC Mechanical lock
models
24-VAC Solenoid lock models
Rated operating voltage
24 VDC
+10%
/
--15%
(100% ED)
110 VAC
±
10% (50/60 Hz)
24 VDC
+10%
/
--15%
(100% ED)
Current consumption
Approx. 300 mA
Approx. 98 mA
Approx. 300 mA
Insulation class
Class F (130
°
C or less)
Indicator Characteristics
Item
LED
Rated voltage
10 to 115 VAC/VDC
Current consumption
Approx. 1 mA
Indicator color (LED)
Orange, green