![Omron D4BL - Manual Download Page 16](http://html1.mh-extra.com/html/omron/d4bl/d4bl_manual_744315016.webp)
D4BL
17
Cable Connection Example
1. Connect the wires to the terminals in the order shown below
for wiring efficiency.
Tighten each wired terminal clockwise to a torque of 0.59 to
0.78 N
S
m.
Twist the wire two or three times and make sure that no bare
wire exists outside the terminal when tightening the terminal.
2. The insulation sheath of the seven-conductor cable must
come into contact with the wall of the conduit mouth, side A
or side B.
Insulation sheath edge
Maintenance and Repairs
Contact your OMRON representative for any repair or
maintenance work on the D4BL. The D4BL must not be
maintained or repaired by any unauthorized party.
Using the D4BL
Do not touch the solenoid because the solenoid radiates heat
while power is being supplied.
OMRON ON-LINE
Global - http://www.omron.com
USA - http://www.omron.com/oei
Canada - http://www.omron.ca
ALL DIMENSIONS SHOWN ARE IN MILLIMETERS. To convert millimeters into inches, divide by 25.4
Cat. No. GC SAFETY-2