background image

D4BL

3

Ordering Information

J

MODEL NUMBER LEGEND

D4BL

-

-

1

2

1. Conduit

1: PG13.5 (European type)

2: G1/2 (Japanese type)

3: 1/2-14NPT (North American type)

2. Built-in Switch

C: 1NC/1NO (Slow-action) + 1NC (Slow-action)

D: 2NC (Slow-action) + 1NC (Slow-action)

3. Head Mounting Direction

R: Mounting possible in 4 directions

(mounted in the right direction at time of delivery)

3

4

D4BL - K

1

Switch

Operation Key (Order Separately)

5

1. Operation Key Type

1: Horizontal mounting

2: Vertical mounting

3: Adjustable mounting (Horizontal)

4. Door Lock/Release Methods

(Auxiliary Release Key is Incorporated by All Models)

5. Indicator

A: Mechanical lock/24-VDC solenoid release

B: Mechanical lock/110-VAC solenoid release

G: 24-VDC Solenoid lock/Mechanical release

Blank: Without indicator

A:

1 mA at 10 to 115 VAC or VDC driving

(with red and green LED indicator unit)

J

SWITCHES

Description

Part number

Lock

method

Conduit size/type

Voltage

for

solenoid

Without indicator

1NC/1NO+ 1NC

(Slow-action)

With LED indicator

1NC/1NO+ 1NC

(Slow-action)

Without indicator

2NC+ 1NC

(Slow-action)

With LED indicator

2NC+ 1NC

(Slow-action)

Mechanical

l k

PG13.5 (European)

24 VDC

D4BL-1CRA

D4BL-1CRA-A

D4BL-1DRA

D4BL-1DRA-A

lock

110 VAC

D4BL-1CRB

D4BL-1CRB-A

D4BL-1DRB

D4BL-1DRB-A

G1/2 (Japanese)

24 VDC

D4BL-2CRA

D4BL-2CRA-A

D4BL-2DRA

D4BL-2DRA-A

110 VAC

D4BL-2CRB

D4BL-2CRB-A

D4BL-2DRB

D4BL-2DRB-A

1/2-14NPT

(N th A

i

)

24 VDC

D4BL-3CRA

D4BL-3CRA-A

D4BL-3DRA

D4BL-3DRA-A

/

(North American)

110 VAC

D4BL-3CRB

D4BL-3CRB-A

D4BL-3DRB

D4BL-3DRB-A

Solenoid

l k

Pg 13.5 (European)

24 VDC

D4BL-1CRG

D4BL-1CRG-A

D4BL-1DRG

D4BL-1DRG-A

lock

G1/2 (Japanese)

24 VDC

D4BL-2CRG

D4BL-2CRG-A

D4BL-2DRG

D4BL-2DRG-A

2 1/2-14NPT

(North American)

24 VDC

D4BL-3CRG

D4BL-3CRG-A

D4BL-3DRG

D4BL-3DRG-A

Summary of Contents for D4BL -

Page 1: ...unlocks the door in the case of a power failure H Tough aluminum die cast Unit incorporating a switch box with IP67 degree of protection EN60529 IEC529 H Standards and EC Directives Conforms to the f...

Page 2: ...mA at 10 to 115 VAC or VDC driving with red and green LED indicator unit J SWITCHES Description Part number Lock method Conduit size type Voltage for solenoid Without indicator 1NC 1NO 1NC Slow actio...

Page 3: ...odel Utilization category AC 15 AC 15 Rated operating current Ie 3 A 6 A Rated operating voltage Ue 250 V 115 V As protection against short circuiting use either a gI type or gG type 10 A fuse IEC269...

Page 4: ...ve voltage at switching 1 500 V max EN60947 5 1 Contact resistance 50 m max initial value Vibration resistance Malfunction 10 to 55 Hz 0 35 mm single amplitude with an imposed acceleration of 50 m s2...

Page 5: ...wiring Solenoid Lock monitor switch Auxiliary release key Operation J CONTACT FORM DIAGRAMS SHOW STATE WITH KEY INSERTED AND LOCK ENGAGED Model Contact Diagrams Remarks D4BL jCjj j 1NC 1NO 1NC 31 32...

Page 6: ...rrent diode Recommended Circuit Connection Example 1 Connect the crimp style terminals of each indicator unit to the internal terminals terminals 31 and 12 23 and 24 and 21 and 22 of the D4BL 2 Each i...

Page 7: ...E1 E2 23 24 12 11 32 31 Operation Key door Orange Green Operation Key The mechanical lock is released contacts 31 and 32 are OFF E1 E2 31 12 23 24 E1 E2 23 24 12 11 32 31 Operation Key door Orange Gr...

Page 8: ...mounting holes Four M4 cover clamping screws 100 0 1 74 0 1 Cover 112 1 0 86 1 0 15 Red J OPERATION KEYS 40 26 40 20 12 80 7 36 5 6 11 8 30 34 6 17 5 2 6 37 8 19 5 0 1 4 dia 5 3 dia 30 0 15 M4 Allen h...

Page 9: ...peration Key insertion radius R 1000 side view 35 81 5 min 85 max 41 41 13 40 0 15 54 5 min 58 max Horizontal direction Operation Key insertion radius R 1200 side view 54 5 min 58 max Vertical directi...

Page 10: ...2 T22 T21 G9S Circuit Diagram PC output PC output Stop signal Feed back loop Operation instruction Emergency stop or standby Closed Open S2 S1 KM1 KM2 S1 D4DN or D4BN Safety door Lock Switch S2 D4BL G...

Page 11: ...rd Lock Safety door Lock Switch with mechanical lock S3 Push button switch for solenoid KM1 KM2 Magnet Contactor LC1 D M 3 phase motor E SW Emergency stop switch A22E Circuit Diagram PC output PC outp...

Page 12: ...the power supply to the D4BL fails Use an appropriate tool to set the auxiliary release key to UNLOCK so that the lock will be released and the door can be opened Auxiliary release key UNLOCK LOCK Th...

Page 13: ...secure it with screws that will tighten when turned clockwise or counterclockwise Set zone Space Door Security The D4BL may break soon if the door opens accidentally or a space is present between the...

Page 14: ...as shown in figures A and B below To change the direction of the head make sure that the protruding part of the rotating lever engages with the groove of the plunger Then turn the head clockwise or c...

Page 15: ...tch box are properly aligned J PROCESSING AND CONNECTING CABLE CONDUIT The following procedures are recommended for mounting and wiring the indicator unit securely In order to ensure IP67 use OMRON s...

Page 16: ...presentative for any repair or maintenance work on the D4BL The D4BL must not be maintained or repaired by any unauthorized party Using the D4BL Do not touch the solenoid because the solenoid radiates...