G-206
Safety Sensors / Components
Solvents
Ensure that solvents, such as alcohol, thinner, trichloroethane, or
gasoline do not adhere to the product. Solvents may cause markings
to fade and components to deteriorate.
Installation Location
Do not install the product in the following locations. Doing so may
result in product failure or malfunction.
•
Locations subject to direct sunlight.
•
Locations subject to temperatures outside the range 25 to 55 °C.
•
Locations subject to humidity levels outside the range 35% to 85%
or subject to condensation due to extreme temperature changes.
•
Locations subject to corrosive or flammable gases.
•
Locations subject to shocks or vibration in excess of the product
ratings.
•
Locations subject to exposure to water, oil, or chemicals.
•
Locations subject to dust (including iron dust) or salts.
Take appropriate and sufficient countermeasures when using the
product in the following locations.
•
Locations subject to static electricity or other forms of noise.
•
Locations subject to possible exposure to radioactivity.
•
Locations close to power supply lines.
Wiring
Perform wiring using wire with the following dimensions.
Stranded wire:
2.5 mm
2
Solid wire:
4.0 mm
2
Tighten the terminal screws with the specified torque. Not doing so
may result in malfunction or abnormal heat generation.
Terminal screw tightening torque: 1 N·m
In the interest of product improvement, specifications are subject to change without notice.
ALL DIMENSIONS SHOWN ARE IN MILLIMETERS.
To convert millimeters into inches, multiply by 0.03937. To convert grams into ounces, multiply by 0.03527.
Cat. No.
C127-E2-02-X