D3C
D3C
256
Dimensions
Mounting Holes
Note:
All units are in millimeters unless otherwise indicated.
4
±
0.1
1.6 dia
5.7
±
0.1
M1.6 tap
Dimensions and Operating Characteristics
Note:
1. All units are in millimeters unless otherwise indicated.
2. Unless otherwise specified, a tolerance of
±
0.4 mm applies to all dimensions.
D3C-1210/-2210
D3C-1220/-2220
6
4.7
3.5
2.5 2.5
0.8
4
8
8.7
6.7
0.3
0.9
1.6
4.2
5.6
1
1R
5.7
±
0.15
4
±
0.15
OP FP
1-dia. hole
1.5
0
–0.15
dia.
1.6
+0.12
0
dia. hole
4.6 max.
Operating
direction (A)
Operating direction (B)
PCB Dimensions
8
4.2
2.54
2.54
Three, 1 dia. hole
Model
Non-shorting Models
Shorting Models
D3C-1210
D3C-1220
D3C-2210
D3C-2220
OF max.
1.28 N {130 gf} (0.98 N)
0.39 N {40 gf} (0.29 N)
1.28 N {130 gf} (0.98 N)
0.39 N {40 gf} (0.29 N)
RF min.
{
g } (
)
0.10 N {10 gf} (0.15 N)
{
g } (
)
0.03 N {3 gf} (0.05 N)
{
g } (
)
0.10 N {10 gf} (0.15 N)
{
g } (
)
0.03 N {3 gf} (0.05 N)
FP max.
4.8 mm
4.8 mm
OP1
3.5
±
0.3 mm
3.4
±
0.3 mm
OP2
2.5
±
0.3 mm
2.6
±
0.3 mm
TTP
1.3
±
0.4 mm
1.3
±
0.4 mm
Note:
The values for operating characteristics apply for operation in the A direction ( ) shown above. The values in parentheses indicate
those for operation in the B direction ( ).
Switching Timing
Non-shorting Model
OP1
(2)
(1)
(3)
(NC)
(NO)
FP
OP2
(2)
(1)
(3)
(NC)
(NO)
OP1
FP
OP2
TTP
TTP
Shorting Model