6
7
Item
Descriptions
Item
Descriptions
Product name
Model
Applicable PLC-series
Applicable Unit
CX-Process Monitor Plus
WS02-LCMC1-EV2
CS/CJ-series
•Loop Control Unit Ver. 2.0 or higher
•Loop Control Board
•Process-control CPU Unit
•Loop-control CPU Unit
Applicable computer
Personal computer
CPU
OS
Memory
Hard disk drive
Monitor
CD-ROM drive
Mouse
Printer
Sound board
Min. required: 128 Mbytes, Recommended: 256 Mbytes or more
Min. required: 650 Mbytes of free space, Recommended: 800 Mbytes or more of free space
Min. required: XGA, Recommended: XGA or higher, min. 1024 x 768 dots, 256 colors
At least one
Recommended: Microsoft mouse or compatible pointing device
Any printer supported by Microsoft Windows
1 board
FinsGateway (One of the following must be installed according to the communications method with the PLC.)
•Serial Unit driver (Host Link)
•Controller Link driver (Controller Link)
•CLK (PCI) driver (Controller Link, PCI bus)
•ETN_UNIT driver (Ethernet)
CSV tags and tags for Monitor Plus (CSV monitor tags) are set using the CX-Process Tool.
These tags are used to specify Loop Control Unit/Board data.
Data collected
(logger function)
Realtime trend
Data display
Horizontal (time) axis: 2, 4, 8, 12 and 24-hour time units can be scrolled
Vertical (8-point common) axis: Graduation can be enlarged by a factor or 1, 2, 5 and 10.
Data is displayed from the time when the specified display start time is reached.
Display color: Red, yellow, green, blue, magenta, purple, cyan, or white
IBM PC/AT or compatible
Min. required: Pentium MMX233 MHz or faster, Recommended: Celeron 400 MHz or faster
Microsoft Windows NT 4.0 (Service Pack 6a or higher), Windows 2000 Professional (Service Pack 4 or higher),
Windows XP Professional (Operation is not supported on Windows 95, 98, or ME.)
Software that must be installed at the same time
Connecting method
Connection with CPU
Unit (or Serial
Communications
Board/Unit)
Using FinsGateway
Serial Unit version
Loop Control Unit/Board data specification method
Prepare user configuration screens for use in the online operation screen.
Offline operation functions
Place buttons for progressing on the Control Screen, Trend Screen, and other screens. Four columns and
eight lines are displayed on each screen (32 screens max.). Alarm status for each loop is displayed on
the button on Control Screens.
Online
operation
functions
Using FinsGateway
CLK (PCI) Driver
Connect the computer to the CPU Unit's peripheral port, RS-232C port,
or the RS-232C port of a Serial Communications Unit.
•Connecting Cable:
When connecting to the CPU Unit peripheral ports: Model CS1W-CN
(2 m, 6 m)
When connecting to the CPU Unit's RS-232C port: Model XW2Z-
-
(2 m, 5 m)
For details on the Connecting Cables, refer to CX-Process Monitor Plus Operation
Manual (Cat. No. W428).
•Communications protocol with PLC: Host Link (not supported on Peripheral bus)
Install the driver in a computer equipped with a Controller Link Support Board
(PCI slot) to support communications between the computer and PLCs equipped
with a Controller Link Unit.
Using FinsGateway
Controller Link
driver
Install the driver in a computer equipped with a Controller Link Support Board
(ISA slot) to support communications between the computer and PLCs equipped
with a Controller Link Unit.
Using FinsGateway
ETN_UNIT driver
Install the FinsGateway ETN_UNIT driver on the computer on which an Ethernet
board is mounted to enable communications with the PLC on which the Ethernet
Unit is mounted.
Connection via Controller Link
Connection via Ethernet
User
Configuration
Screen
Online
operation
functions
User
Configuration
Screen
Overview Screen
Control Screen
Tuning Screen
The analog signals output from tag ITEMs for each function block can be collected at fixed intervals and
saved to a file. If necessary, up to 8 analog signals can be displayed on one screen in the form of
a multi-dot recorder.
Trend Screen
Stores 10, 20, 50, 100, or 300
hours of data for up to 480
tags sampled at 1, 2, 5, 10, or
30-second intervals.
Historical trend
Stores 30, 150, 300, 900, or
1,800 days of data for up to
960 tags sampled at 1, 5, 10,
30, or 60-minute intervals.
Data can be saved in CSV format
either using button commands,
or automatically at a set interval
(every 1, 2, 3, 4, 6, 8, 10, 12, 18,
20, 24, 48, 72, 96, 120, or 240
hours).
Displays the PV trend for the settings in Segment Program 2 (Block Model 157).
Segments can be set in table format while observing a time axis graph.
Segment Program
2 Screen
This screen displays changes in the plant status using graphic elements representing plant devices pasted
to the screen from the graphic elements library. The maximum number of screens is 200.
Graphics/graphic parts: Text, straight lines, rectangles, rectangles with rounded corners, ellipses,
polygons, images
Functional Objects Provided in Library
•Fixed graphic elements provided in library: Text, instruments, thermometers, transmitters, orifices
•Variable graphic elements provided in library:
Analog display: Bar graph display, numeric indication, tanks
Analog settings: Numeric settings
Contact display: Pumps, valves, pipes
Contact operation: Switches
•Screen-displaying elements: Jump (screen jump) elements and FP switch (faceplate pop-up) elements
•Individual Graphic Screens can be imported/exported as files.
•Multiple graphic elements can be grouped and imported/exported as files.
Graphic Screen
This screen notifies the operator of alarms or errors that occur by changing the display color and emitting
sound. A message with two lines of 16 characters each is displayed on the screen at the same time.
A total of 16 screen elements (4 columns x 4 lines) can be displayed on each screen. The maximum number
of screens is 5.
Annunciator Screen
This screen displays the Loop Control Unit/Board system error information.
System Monitor Screen
This screen displays logs of the run/stop history and a history of execution errors that occur on the Loop
Control Unit/Board together with the date and time of occurrence.
Output possible in CSV format.
System Monitor Log
Screen
This screen displays a pre-registered message with two lines of 64 characters each
together with the date of occurrence when the specified internal switch is set to ON.
Max. number of registerable messages: 1,000, Number of display colors: 16
Up to 1,000 messages are displayed in a single screen.
Output possible in CSV format.
Operation Guide
Message Screen
A record of alarms (time of error occurrence, tag name, PV or MV current value at occurrence, alarm type,
etc.) that occur and that are input from the Control and Alarm blocks is saved and displayed as a list later.
Up to 1,000 alarm messages are displayed in a single screen.
Output possible in CSV format.
Alarm Log Screen
Operation logs of data elements and switches in Graphic Screens and a record of changes (date and time
of operation, tag name, original ITEM data setting, new ITEM data setting, etc.) made to ITEM data on the
Loop Control Unit/Board in the Control or Tuning Screen are saved and displayed as lists later.
Up to 1,000 operation messages are displayed in a single screen.
Output possible in CSV format.
Operation Log
Screen
System Fixed
Screen
Data display
Horizontal (time) axis: The time axis can be scrolled in 2, 4, 8, 12, 24, or 72-hour time units.
Vertical axis: Scale can be enlarged by a factor or 1, 2, 5 and 10.
Data is displayed from the time when the specified display start time is reached.
Display color: Yellow, blue, green, or violet
Data collection
Stores 3, 30, or 180 days of data sampled at 1,
10, or 60-second intervals.
Data can be saved manually in
CSV format by pressing a button,
or it can be saved automatically
in CSV format each time a batch is
completed. Past data is saved
automatically as binary data.
Data display
Horizontal (time) axis: The time axis can be scrolled in the following time units.
1, 2, 4, 6, 8, 12, 24, 36, 48, or 72 hours
7 or 10 days
Vertical (8-point common) axis: Scale can be enlarged by a factor or 1, 2, 5 or 10.
Data is displayed from the time when the specified display start time is reached.
Display color: Red, yellow, green, blue, magenta, purple, cyan, or white
CX-Process Monitor Plus Specifications
CX-Process Monitor Plus Specifications
The analog signals output from each function block's tag ITEMs can be collected at fixed intervals and
stored automatically when a specified tag data condition is met. Past data can be superimposed on the chart.
Batch Trend Screen
Data collection
Stores 10 days or 4 hours of data for up to 960
tags sampled at 1-minute or 1-second intervals.
Data can be saved manually in
CSV format by pressing a button,
or it can be saved automatically
in CSV format each time a batch is
completed. Past data is saved
automatically as binary data.
Control blocks such as the PID blocks and Indication blocks, and some Operation blocks are displayed for up
to 8 loops in a single screen in the form of a field device. The maximum number of screens is 400.
This screen displays the SP, PV, and MV numeric values, displays a PV as a bar graph that can be scaled,
and can be used for changing the SP, MAN, and other setting values. When an alarm occurs, the color of the
bar graphs changes. You can progress to the Tuning Screen from the Control Screen.
This screen is for setting P, I, and D parameters in control blocks such as the PID blocks. The PV, SP, and MV
can be monitored while tuning the parameters. The maximum number of screens is 400 x 8 = 3,200.
When an alarm occurs, the color of the bar graphs changes.
Fine-tuning according to the degree specified by the user is possible for PID constants.