background image

Integrated simulation can now be 
started from the CX-Programmer!

4

5

Integrated simulation can be started 
from either the CX-Programmer or the 
CX-Designer. This enables more easily 
performing integrated simulation and 
debugging.

Now, system errors can be easily 
checked using only a computer!

Operation of monitoring 
programming when errors occur can 
be verified on a computer. 
Saving operations in CSV files when 
errors occur simplifies making test 
reports. 

Now, variable data can be easily 
copied from the CX-Designer to 
the CX-Programmer. 

Variable data can be easily shared. 
No work is required to manage data 
allocations. 
Comments can also be copied. 

Integrated Simulation for Greater Design and Deb  ugging Efficiency

Even Easier Integrated Simulations! 
Greatly Improved Design Efficiency!  

The CX-One is even easier to use through the addition of functions from CX-One version 2.0, 
such as starting simulation from the CX-Programmer and customizing test screens. 

A New PLC Error Simulator Enables Easily Checking 
Operation of Debugged Programs When System Errors Occur!

The coverage of integrated simulation has been further expanded by enabling generation of PLC system errors on the computer, thus 
eliminating the need to use actual equipment. This allows the user, for example, to easily debug programming that handles system errors. 

Variable data can be easily shared between 
the CX-Programmer and CX-Designer!

The ability to easily copy and paste CX-Designer variable data to the CX-Programmer further improves the efficiency of integrated simulation. 
For example, variables that have been changed due to revisions in touch panel screens can be easily updated in the CX-Programmer. 

1

2

3

Position OK!

Starting from the CX-Programmer 

Starting from the CX-Designer 

Starting Integrated Simulation

PLC Error Simulator 

Sharing Variable Data 

Version 

Upgrade 

Version 

Upgrade 

Integrated Simulation between PLCs and Touch Panels 

1  Start integrated simulation with 
    the press of a button. 

1  Start integrated simulation with 
    the press of a button. 

2  Select the CX-Designer file. 

2  Select the CX-Programmer file. 

3  Click the Start Button. 

3  Click the Start Button. 

During simulation, it is 
possible to change the 
touch panel display 
position, pin the screen 
display on top, and 
specify the size.

Variable names
Addresses
Comments 

Variable names
Addresses
Comments 

New adjustment functions enable
customizing the debugging environment!

The size of the PT screen can be changed.

The PT screens can be kept displayed in front.

The PT screen position can be saved. 

Startup has been 

completed!

NEW

NEW!

CX-Programmer Support 
Software for PLCs

CX-Designer Screen Designing 
Software for NS-series PT 
Touch Panels

Integrated simulation could be started 
only from the CX-Designer, even though
starting from the CX-Programmer 
would sometimes be more convenient. 
There was also the need to customize 
screen positioning and other factors in 
the debugging environment, and to 
keep the PT screens displayed in front.

Previously, error-handling programming 
was verified by generating errors using 
error-generation commands in a 
program running on the PLC. 
Preparation and execution required too 
much time. 

Previously, it was possible to copy and 
paste from the CX-Programmer to the 
CX-Designer, but not in the opposite 
direction. It was a lot of trouble to bring 
variable data created in the CX-Designer 
to the CX-Programmer. 

CX-Programmer Support Software 
for PLCs

CX-Designer  
Screen Designing Software for 
NS-series PT Touch Panels

Starting was 
not possible.

Starting was 
possible.