Important safety instructions

Read all the information in the instruction manual and any other literature included in the box before 
using the device.

 Warning:

Indicates a potentially hazardous situation which, if not avoided, could result in serious injury.

(Usage)

• For type, dose, and regime of medication follow the instructions of your doctor or respiratory therapist.

• If you experience any allergic reactions or other difficulties during use, stop using the device immediately 

and consult your doctor.

• Do not use only water in the nebulizer for inhaling purposes.

• Keep the device out of reach of unsupervised infants and children. The device may contain small pieces 

that can be swallowed.

• Do not store the air tube while there is moisture or medication remaining inside.

• Do not use or store the device where it may be exposed to noxious fumes or volatile substances.

• Do not use the device where it may be exposed to flammable gas.

• Do not cover the compressor with a blanket, towel, or any other type of cover during use.

•  Always dispose of any remaining medication after use, and use fresh medication each time.

• Do not use in anaesthetic or ventilator breathing circuits.

• Store the parts in a clean location to avoid infection.

(Risk of electrical shock)

• Never plug or unplug the AC adapter with wet hands.

•  The compressor and the AC adapter are not waterproof. Do not spill water or other liquids on these parts. 

If liquid does spill on these parts, immediately unplug the AC adapter and wipe off the liquid with gauze or 

other absorbent material.  

• Do not immerse the compressor in water or other liquid.

• Do not use or store the device in humid locations.

• Do not operate the device with a damaged power cord or plug.

• Keep the power cord away from heated surfaces.

• Use only original OMRON AC adapter. Use of unsupported AC adapter may damage the device.

(Cleaning and disinfecting)

Observe the rules below when cleaning or disinfecting parts. Failure to observe these rules may result 

in damage, inefficient nebulization or infection. For the instructions, refer to “Cleaning and disinfecting” 

section.

• Clean and disinfect the nebulizer kit, mask, mouthpiece or nosepiece before using them when as 

follows:

 - the first time after purchase.

 - if the device has not been used for a long period of time

 - if more than one person uses the same device

• Be sure to wash or wipe the parts after use, and ensure that they are thoroughly disinfected and dried, 

and stored in a clean location.

• Do not leave the cleaning solution to dry on parts.

Summary of Contents for COMP A-I-R C21 basic

Page 1: ...EN 9701707 1D_NE C803 RU_IM_M02_191220 pdf Compressor Nebulizer C21 basic NE C803 RU Instruction Manual IM NE C803 RU 05 11 2019 9701707 1D Issue Date 2020 03 02 20A0047 RU...

Page 2: ...nel is mixed with compressed air which is generated by a compressor pump The medication is turned into fine particles and sprayed when in contact with the compressed air Aerosol Nozzle Compressed Air...

Page 3: ...ot breathing spontaneously Environment This product is intended for use in a medical facility such as Hospital clinic and doctor s office and in a room of general household Durable period Durable peri...

Page 4: ...athing circuits Store the parts in a clean location to avoid infection Risk of electrical shock Never plug or unplug the AC adapter with wet hands The compressor and the AC adapter are not waterproof...

Page 5: ...ld temperature or under direct sunlight Do not use the device while sleeping or if drowsy Approved for human use only The compressor may become hot during operation Do not touch the compressor for oth...

Page 6: ...compressor operates normally When using this device there will be some noise and vibration caused by the pump in the compressor There will also be some noise caused by the emission of compressed air...

Page 7: ...r Air Filter Cover Air filter inside Compressor Main Unit x 1 Nebulizer Kit Holder Air Tube Connector Power Switch Spare Air Filters x 5 Air Tube PVC 100cm x 1 Mouthpiece x 1 Child Mask PVC x 1 Adult...

Page 8: ...dult Mask PVC NEB MSLP E Child Mask PVC NEB MSMP E Adult Mask SEBS NEB MSLS E Child Mask SEBS Mask Adapter set NEB MSSS E Mouthpiece NEB MP E Nosepiece NEB NP E Air Tube PVC 100cm NEB TP 82E AC Adapte...

Page 9: ...sinfecting section 1 Make sure that the power switch is in the off position 2 Connect the AC adapter to the compressor and plug the power plug into a power outlet Note Do not place the device in a loc...

Page 10: ...ot attached in the correct orientation it will not nebulize correctly 6 Put the inhalation top back inside the medication tank 1 Align the protrusion on the inhalation top with the indent on the medic...

Page 11: ...e attachments are fitted in such a way that the handle is positioned away from the patient Otherwise medication may be sprayed on patient s skin or clothes 8 Attach the air tube Push the air tube plug...

Page 12: ...o the mouth or it may result in not nebulizing effectively 10 Press the power switch to the on position As the compressor starts nebulization begins and aerosol is generated Inhale the medication 11 W...

Page 13: ...dication tank Mask PVC SEBS Mouthpiece Nosepiece Wash them in warm water and mild detergent neutral detergent Rinse them thoroughly with clean hot tap water and allow to air dry in a clean place Vapor...

Page 14: ...ake off excess water and allow to air dry in a clean environment An example of commercially available disinfectant The concentration and residence time specified in the table are under the conditions...

Page 15: ...sture Changing the air filter If the air filter has been used for more than 60 days replace it with a new one 1 Pull the air filter cover off the compressor 2 Change the air filter 3 Put the air filte...

Page 16: ...bled correctly Assemble the nebulizer kit correctly Is the nozzle blocked Make sure that the nozzle is free of blockages Is the nebulizer kit tilted at a sharp angle Make sure that the nebulizer kit i...

Page 17: ...Mask Nosepiece IP21 Ingress Protection Package Contents Compressor Nebulizer Kit air tube PVC 100cm Mouthpiece Nosepiece Adult Mask PVC Child Mask PVC AC Adapter HHP CM01 5 pcs Spare Air Filters Stora...

Page 18: ...ntinuous operation Please report to the manufacturer and the competent authority of the Member State in which you are established about any serious incident that has occurred in relation to this devic...

Page 19: ...nating current Direct current Date of manufacture YYYY MM DD EN 60601 1 IEC 60601 1 Certified by T V Efficiency Level of power supply Trademark of OMRON compressor nebulizers COMP A I R COMP A I R bas...

Page 20: ...ure inside the air tube 400kPa Result of cascade impactor measurements for particle size 0 10 20 30 40 50 60 70 80 90 100 0 1 1 10 100 Cumulative particle mass of sodium fluoride under size Particle S...

Page 21: ...or its literature indicates that it should not be disposed of with other household wastes at the end of its working life To prevent possible harm to the environment or human health from uncontrolled...

Page 22: ...HE NETHERLANDS www omron healthcare com Importer in EU Production facility OMRON DALIAN Co Ltd No 3 Song Jiang Road Economic and Technical Development Zone Dalian 116600 China Exclusive distributor an...

Page 23: ...RU NE C803 E_A_M09_140715 pdf C21 basic NE C803 RU 2020 03 02...

Page 24: ...24 OMRON C21 basic 24 25 26 29 30 30 31 35 37 37 38 39...

Page 25: ...25 RU C21 basic 2 2 7 5 23 C 5 1 1 1 100 1 60 1...

Page 26: ...26 OMRON...

Page 27: ...27 RU 60 ee 45 10...

Page 28: ...28 30 OMRON HEALTHCARE 40 C...

Page 29: ...29 RU HHP CM01 x 1 x 1 x 1 x 5 100 x 1 x 1 x 1 x 1 x 1 x 1...

Page 30: ...30 NEB NSET3 83E NEB MSLP E NEB MSMP E NEB MSLS E NEB MSSS E NEB MP E NEB NP E 100 NEB TP 82E HHP CM01 x 5 NEB AFR 30E...

Page 31: ...31 RU 1 2 3 4...

Page 32: ...32 5 6 1 2...

Page 33: ...33 RU 7 8...

Page 34: ...34 9 45 10 11 45 45...

Page 35: ...35 RU 36...

Page 36: ...36 o X 100 A o o o o o X X o o o o o X X 0 1 15 B o o o o X X X A B 15 20...

Page 37: ...37 RU 1 2 3 60 1 2 3 OMRON...

Page 38: ...38 30 45 OMRON...

Page 39: ...C21 basic NE C803 RU 100 240 50 60 0 12 0 065 6 0 7 10 40 C 30 85 700 1060 20 60 C 10 95 700 1060 180 602 85 43 115 x x II BF IP21 100 HHP CM01 5 OMRON OMRON HEALTHCARE 20 C 30 93 42 EEC EN13544 1 200...

Page 40: ...40 IP IEC 60529 12 5 OMRON HEALTHCARE EUROPE URL www omron healthcare com BF II IP XX 60529...

Page 41: ...41 RU EN 60601 1 IEC 60601 1 T V OMRON COMP A I R COMP A I R basic COMP A I R Elite COMP A I R Pro OMRON HEALTHCARE...

Page 42: ...5 MMAD Mass Median Aerodynamic Diameter 5 63 10 10 2 10 0 5 1 1 45 0 24 0 28 0 36 0 39 2 1 NaF 0 04 0 05 2 1 NaF 400 0 10 20 30 40 50 60 70 80 90 100 0 1 1 10 100 Dp OMRON HEALTHCARE Co Ltd 23 C 40 E...

Page 43: ...4799 19 10 2017 JP 18 01672 30 10 2017 30 10 2020 50444 92 3 4 60601 1 2010 60601 1 2 2014 020 2011 N RU JP 75 00616 31 10 2022 C21 basic NE C803 RU OMRON HEALTHCARE Co Ltd EN60601 1 2 2015 OMRON 30 1...

Page 44: ...0 4 3 10 80 2 7 80 1 IEC 61000 4 3 3 IEC 61000 4 4 2 100 IEC 61000 4 5 0 5 1 IEC 61000 4 6 6 2 150 80 80 AM 1 IEC 61000 4 8 30 A m 50 IEC 61000 4 11 0 UT 0 5 0 45 90 135 180 225 270 315 0 UT 1 70 UT 2...

Page 45: ...0 3 9 745 780 810 800 960 GSM 800 900 TETRA 800 iDEN 820 CDMA 850 LTE Band 5 18 2 0 3 28 870 930 1720 1700 1990 GSM 1800 CDMA 1900 GSM 1900 DECT LTE Band 1 3 4 25 UMTS 217 2 0 3 28 1845 1970 2450 240...

Page 46: ...46 2 1 7 2790 10...

Page 47: ...47 RU...

Page 48: ...617 0002 OMRON HEALTHCARE EUROPE B V Scorpius 33 2132 LR Hoofddorp THE NETHERLANDS 33 2132 www omron healthcare com OMRON DALIAN Co Ltd No 3 Song Jiang Road Economic and Technical Development Zone Da...

Reviews: