6
Type the
#4 j=0
command in the Power
PMAC IDE Terminal and confirm that
Gate3[1].Chan[1].SerialEncDataA=0 is
displayed.
7
Confirm that the guide laser light is out-
put to the center of the XY table.
8
Type the
#5 j={Position}
command in
the Power PMAC IDE Terminal and
confirm that the spot diameter of guide
laser light is appropriate.
9
Type the
GuideLaser=0
command in
the Power PMAC IDE Terminal and
confirm that guide laser light is not out-
put.
3-7-3
Programming
Program the settings of the laser oscillator.
1
In the Solution Explorer, right-click
Global
Includes
under
PMAC Script Language
and select
Add
–
New Item...
.
3 Connection Procedures
3-53
Application Guide Laser Application (O052)
3-7 Setup of the Laser Oscillator
3
3-7-3
Programming