19
Instruction for
C200HX/HG/HE
Instruction for CJ2
Operand
Number of operands
MTR(213)
MTR(213)
The fourth operand is added.
The fourth operand specifies a work word used by this
instruction. As this word cannot be used for any other
purpose, change to another area when the area
assigned by conversion is the area used for another
purpose.
Changed from 3 to 4.
7SEG(214)
7SEG(214)
The fourth operand is added.
The fourth operand specifies a work word used by this
instruction. As this word cannot be used for any other
purpose, change to another area when the area
assigned by conversion is the area used for another
purpose.
Changed from 3 to 4.
IORD(222)
IORD(222)
The specifications of the operands are changed. Refer to
the
CS1/CJ1/CJ2/NSJ SYSMAC CS/CJ SERIES
SYSMAC ONE NSJ SERIES PROGRAMMABLE
CONTROLLERS INSTRUCTIONS REFERENCE
MANUAL
(Cat. No.W474), and change the settings.
Same
IOWR(223)
IOWR(223)
The specifications of the operands are changed. Refer to
the
CS1/CJ1/CJ2/NSJ SYSMAC CS/CJ SERIES
SYSMAC ONE NSJ SERIES PROGRAMMABLE
CONTROLLERS INSTRUCTIONS REFERENCE
MANUAL
(Cat. No.W474), and change the settings.
Same
RXD(235)
RXD(235)
This instruction cannot specify the peripheral port.
The data type of the number of bytes to store (third
operand) is changed from BCD to binary.
When a constant is specified, "#" is automatically
converted to "&".
When a word address is specified, change the data type
of the word from BCD to binary.
Same
TXD(236)
TXD(236)
This instruction cannot specify the peripheral port.
The data type of the number of bytes (third operand) is
changed from BCD to binary.
When a constant is specified, "#" is automatically
converted to "&".
When a word address is specified, change the data type
of the word from BCD to binary.
Same
STUP(237)
STUP(237)
The specification of the control word (port) (first operand)
is changed. Refer to the manual to change the settings.
Same
PMCR(260)
PMCR(260)
The specification of the control word 1 (first operand) is
changed. Refer to the manual to change the settings.
Changed from 3 to 4.
CMCR(261)
Not supported
Insert the memory card into the CPU Unit and use FREAD(700) or FWRIT(701)
instead.
FPD(269)
FPD(269)
The data types of the FAL number of the control word
(first operand) and monitoring time (second operand) are
changed from BCD to binary.
Same
XDMR(280)
Not supported
Use XFER(070) or XFERC(565) instead.
EMBC(281)
EMBC(281)
The data type of the operand is changed from BCD to
binary.
When a constant is specified, "#" is automatically
converted to "&".
When a word address is specified, change the data type
of the word from BCD to binary.
Same
TST(350)
TST(350)
The data type of the second operand is changed from
BCD to binary.
When a constant is specified, "#" is automatically
converted to "&".
When a word address is specified, change the data type
of the word from BCD to binary.
Same
TSTN(351)
TSTN(351)
The data type of the second operand is changed from
BCD to binary.
When a constant is specified, "#" is automatically
converted to "&".
When a word address is specified, change the data type
of the word from BCD to binary.
Same
ADBL(480)
+CL(403)
Same as C200HX/HG/HE
Same
SBBL(481)
-CL(413)
Same as C200HX/HG/HE
Same
MBSL(482)
*L(421)
Same as C200HX/HG/HE
Same
DBSL(483)
/L(431)
Same as C200HX/HG/HE
Same
MBS(484)
*(420)
Same as C200HX/HG/HE
Same
DBS(485)
/(430)
Same as C200HX/HG/HE
Same
BXF2
Not supported
Use XFER(070) or XFERC(565) instead.
XFR2
Not supported
Use XFER(070) or XFERC(565) instead.
IEMS
Not supported
Specify another address by using an Index Register.
NEG(--)
NEG(160)
Same as C200HX/HG/HE
However, if NEG Flag UF (25405) is used, change the
Condition flags to P_N (Negative Flag).
Same
NEGL(--)
NEGL(161)
Same as C200HX/HG/HE
However, if NEGL Flag UF (25405) is used, change the
Condition flags to P_N (Negative Flag).
Same