2. Control Circuit Terminals
Symbol
Name
Function
Signal Level
Input
S1
Forward/Stop
Forward at ON/Stops at OFF
Photocoupler 8 mA
at 24 V DC
*1
*1 NPN is the setting for these terminals. No external power supply is required. Refer to connections shown below
S2
Multi-function Input 1
Set by parameter n36 (Reverse/Stop)
*2
*2 Functions in parentheses are default settings.
S3
Multi-function Input 2
Set by parameter n37 (External Fault: NO)
*2
S4
Multi-function Input 3
Set by parameter n38 (Fault Reset)
*2
S5
Multi-function Input 4
Set by parameter n39
(Multi-step reference 1)
*2
SC Sequence Input Common
Common for S1 through S5
FS
Frequency Reference Power Supply DC power supply for frequency reference use
20 mA at 12 V DC
FR
Frequency Reference Input
Input terminal for frequency reference use
0 to 10 V DC (20 k
Ω
)
FC
Frequency Reference Common
Common for frequency reference use
4 to 20 mA
0 to 20 mA
Output
MA
MB
Multi-function output: NO
Multi-function output: NC
Set by parameter n40 (during running)
*2
Relay output 1 A
max. at 30 V DC and
250 V AC
MC Multi-function output Common
Common for MA and MB use
AM Analogue Monitor output
Set by parameter n44 (Output frequency)
*2
12 mA max. at 0 to
10 V DC
AC Analogue Monitor output Common
Common for AM use
Selecting Input Method
Switches SW7and SW8, both of
which are located above the cont-
rol circuit terminals, are used for in-
put method selection.
Remove the front cover and optio-
nal cover to use these switches.
Selecting Sequence Input Method
By using SW7, NPN or PNP input can be selected as shown below
Control circuit
terminal block
Control circuit
terminal block
SW7
SW8
PNP
NPN
SW7
V
I
SW8
OFF
NPN
(Default setting)
S1 to 5
SC
GND
SW7
24V
360
3.3k
GND
0.1µ
S1 to 5
SC
GND
SW7
24V
360
3.3k
GND
0.1µ
PNP
24 V DC
(±10%)