background image

ENGLISH

5 series

Blood Pressure Monitor

Model BP742CAN

INSTRUCTION MANUAL

Summary of Contents for BP742CAN

Page 1: ...ENGLISH 5 series Blood Pressure Monitor Model BP742CAN INSTRUCTION MANUAL...

Page 2: ...ension Indicator 9 Using the Memory Function 10 Battery Installation 11 Battery Replacement 12 Setting the Date and Time 13 Applying the Arm Cuff 15 Applying the Cuff on the Left Arm 15 Applying the C...

Page 3: ...mes with the following components Monitor Standard Adult Arm Cuff 4 AA Alkaline Batteries Instruction Manual printed in English and French Quick Start Guide The BP742CAN 5 series Automatic Blood Press...

Page 4: ...tially hazardous situation which if not avoided may result in minor or moderate injury to the user or patient or damage to the equipment or other property OPERATING THE DEVICE Contact your physician f...

Page 5: ...able local regulations Unlawful disposal may cause environmental pollution Do not use a cellular phone near the device It may result in an operational failure Use only Omron authorized parts and acces...

Page 6: ...your left arm on table so that the cuff is at the same level as your heart 6 Remain still and do not talk during the measurement 7 Wait 2 3 minutes between measurements The wait time allows the arter...

Page 7: ...Components Quick Start Guide Instruction Manual Standard Adult Arm Cuff Date Time setting button Air Jack Air plug Air tube Display AC adapter Jack Battery compartment Up Down buttons USER ID Selectio...

Page 8: ...ion symbol Pulse display Heartbeat symbol Hypertension Indicator Date Time Display Irregular Heartbeat symbol Movement error symbol Average Value symbol Memory symbol Displayed when viewing values sto...

Page 9: ...rror Symbol is displayed if you move your body during the measurement Please remove the arm cuff and wait 2 3 minutes Reapply the arm cuff and take another measurement AVERAGE VALUE SYMBOL The Average...

Page 10: ...eline because blood pressure depends on age and morbidity The CHS recommends a lower home blood pressure goal for certain patients including people with diabetes or kidney disease1 WARNING The monitor...

Page 11: ...th this device 1 Press the indicator on the battery cover and slide the cover off in the direction of the arrow 2 Install 4 AA size batteries so the positive and negative polarities match the polariti...

Page 12: ...Turn the unit off before replacing the batteries If the batteries are removed while the unit is still on the date and time will be reset to that of the previous use However the measurement results ar...

Page 13: ...Date Time Setting button to adjust the date and time The year flashes on the display 2 SETTING THE YEAR The year can be set between 2010 and 2040 When the display reaches 2040 it will return to 2010...

Page 14: ...n the display 5 SETTING THE HOUR The time is set using AM or PM Press the Up button to advance by one hour Press the Date Time Setting button to set the current hour The minute flashes on the display...

Page 15: ...ING THE CUFF ON THE LEFT ARM 1 Make sure the air plug is securely inserted in the main unit 2 Remove tight fitting clothing from your upper arm 3 Apply the cuff to your left upper arm so the arrow is...

Page 16: ...p 3 Apply the cuff to your right upper arm so the arrow and the air tube runs along the inside of your arm The bottom of the cuff should be approximately 1 2 above your elbow NOTE Be careful not to re...

Page 17: ...ill and do not talk during measurement 4 Press the START STOP button The cuff starts to inflate automatically As the cuff inflates the monitor automatically determines your ideal inflation level Remai...

Page 18: ...onitor will automatically turn off after five minutes SPECIAL CONDITIONS CAUTION Inflating to a higher pressure than necessary may result in bruising where the cuff is applied If your systolic pressur...

Page 19: ...NOTE If two sets of measurement values are stored in the memory for the 10 minutes period the average is based on the two sets of measurement values If one set of measurement values is stored this is...

Page 20: ...es faster TO DELETE ALL VALUES STORED IN THE MEMORY The values stored in the memory are deleted by USER ID You cannot partially delete values stored in the memory All values for the user you select wi...

Page 21: ...t sunlight CAUTION Store the device and the components in a clean safe location CAUTION Do not subject the monitor to strong shocks such as dropping the unit on the floor Remove the batteries if the u...

Page 22: ...3 minutes Take another measurement Cuff over inflated Device error Contact Customer Service Movement during measurement Keep still and take another measurement Irregular or weak pulses are detected R...

Page 23: ...ones Check the battery installation for proper placement of the battery polarities Measurement values appear too high or too low Blood pressure varies constantly Many factors including stress time of...

Page 24: ...y one or more of the following measures Reorient or relocate the receiving antenna Increase the separation between the product and the receiver Connect the product into an outlet on a circuit differen...

Page 25: ...d handling fee Enclose the Proof of Purchase Include a letter with your name address phone number and description of the specific problem Pack the product carefully to prevent damage in transit Becaus...

Page 26: ...ty 50 F to 104 F 10 C to 40 C 15 to 90 RH Storage Temperature Humidity Air Pressure 4 F to 140 F 20 C to 60 C 10 to 95 RH 700 1060 hPa Main Unit Weight Approximately 12 oz 340g not including batteries...

Page 27: ...Omron Healthcare Inc 1200 Lakeside Drive Bannockburn IL 60015 www omronhealthcare ca Copyright 2010 Omron Healthcare Inc Made in China 5330254 2A...