Rack-mount installation

 

When attaching to a rack, detach the rubber feet from the bottom surface of the unit. 

  When using an EIA 19-inch rack 

 

When attaching to the rack, use BHP60P mounting brackets (sold separately) to connect the UPS body 

with the battery unit. For details, refer to the instruction manual included with the rack-mount brackets 

(BHP60P) and support angles (BUP06).  

  When using a JIS 19-inch rack 

 

When attaching to the rack, use BHP60J mounting brackets (sold 

separately) to connect the UPS body with the battery unit. 

  BUP06  support  angles  are  not  compatible  with  JIS  standards. 

Use a rack shelf. 

  For details, refer to the instruction manual included with the rack-

mount brackets (BHP60J). 

  For details, refer to the instruction manual included with the rack-

mount brackets (BHP60P) and support angles (BUP06). Support 

angles are not compatible. Use a server rack. 

2-2  Connecting the battery unit

 

Up to 5 battery units can be connected to the 1kVA-type BH100PCW. 

 

Additional battery units also use the same model of BHM100PC (for 1kVA) as the first unit. 

Use  support  angles  (BUP06)  to  sup-
port each unit that is joined. 

UPS

BH100PCW

Battery unit 1

BHM100PC

Battery units 2 to 5

BHM100PC

Max. total of 5

Run the battery cable through 

the connector cover, connect 

the cable, and screw 

the connector cover shut. 

*When adding a BHM100PC, remove the connector attached at shipment and connect the cable.

 

Each battery unit is equipped with a charging circuit. 

  The charging time does not increase when a battery unit is added. 

Summary of Contents for BHM100PC

Page 1: ...portant com puter systems or communication equipment Applications with the same level of importance as those described above Indicates a prohibited action something you must not do For example indicates that disas sembly is prohibited Indicates a necessary action something you must do For example indicates that grounding is necessary This manual contains important information regarding the safe us...

Page 2: ...s or is dropped Do not pinch or tie the cable of the unit Doing so may damage the cable or cause it to become hot resulting in an electric shock or a fire If the cable is damaged immediately stop using the unit and have it repaired All of the included accessories are designed to be used exclusively with the unit Do not use the accessories with other devices Doing so may compromise the safety of de...

Page 3: ...instruction manual Ambient temperature Expected life 20 C 5 to 7 years 30 C 3 to 4 years 40 C 1 5 to 2 years 50 C 0 7 to 1 years Caution use Battery can be replaced while the unit is stopped only When replacing the battery stop the connected devices turn off the power supply UPS output switch and disconnect the AC input plug from the wall outlet Do not insert metal objects into the battery connect...

Page 4: ...hase If you do not use the unit for a long time after purchase the battery performance may deteriorate and it may become un usable The battery can be charged once the AC input plug of the UPS is connected to a wall outlet commercial power When storing the UPS charge the battery and turn OFF the power switch The battery discharges even when it not being used and it goes into over discharge state if...

Page 5: ...attery units can be connected Do not connect more than 2 units For information about units with no additional battery units connected refer to the BH100PCW BH60P CW instruction manual Correct positions Horizontal Vertical For vertical placement make sure to position in this way BH100PCW BHM100PC BHM100PC BHM100PC Incorrect positions Do not position the unit upside down Do not position the unit so ...

Page 6: ...luded with the rack mount brackets BHP60J For details refer to the instruction manual included with the rack mount brackets BHP60P and support angles BUP06 Support angles are not compatible Use a server rack 2 2 Connecting the battery unit Up to 5 battery units can be connected to the 1kVA type BH100PCW Additional battery units also use the same model of BHM100PC for 1kVA as the first unit Use sup...

Page 7: ...are a valuable recyclable resource Please recycle For information about recycling please contact our Electronic Systems Equipments repair center Be careful not to lose the screws that you remove 2 Disconnect the 2 battery connectors and loosen the 4 screws to remove the fixing bracket Press firmly on this part when removing Caution When an UPS is used in compliance with UL CE standards do not repl...

Page 8: ... Be careful not to drop the battery 4 Insert the new battery and attach the fixing bracket Insert the battery with the label side facing upward wire is on right side 5 Connect the connectors Make sure the connector locks are firmly secured 6 Attach the front panel ...

Page 9: ...the UPS monitoring software included with the UPS keep a record of the software usage start date This unit uses a lead acid battery ALead acid batteries are a valuable recyclable resource Please recycle For information about recycling please contact our Electronic Systems Equipments repair center Notes 4 Replacing the battery unit The UPS BH60PCW BH100PCW battery unit BHM60PC BHM100PC can be repla...

Page 10: ...it After replacing the battery unit make sure to reconnect all of the disconnected cables Make sure the battery unit s built in battery connector in the front panel is connected If commercial power is supplied to the battery unit make sure the charging indicator on the battery unit s front panel is illuminated 3 When you finish connecting the battery press and hold the indicator selection switch o...

Page 11: ...A Inverter unit Output filter Signal connection RS 232C Communication Interface External contact Interface Battery unit Charger Indicators BHM60PC BHM100PC BH60PCW RE60FW BH100PCW RE100FW Gate drive Digital controller Detection circuit NF Output 100 to 120 VAC A B C LED operation panel Step up Converter Circuit block diagram ...

Page 12: ...12 K1L D 05100D Unauthorized reproduction of this manual in part or in whole is prohibited The contents of this manual are subject to change without notice OMRON Corporation 2006 All Rights Reserved ...

Reviews: