LCD Digital Operator 

 

LCD Digital Operator User's Manual v0_90 110218.doc 

Issue 0.90 Draft 

 

 

 

2.1. Operation Key 

 

 

NO.  Key image 

Key Name 

Function 

 

REMOTE 

It  changes  from  Local  to  Remote  mode.  Press  the  key 
during  2  seconds  to  change  from  Local  to  Remote  or 
Remote to Local. When  it  is  in  Local the OPE  led  will  be 
ON.  Use  Local  to  control  the  motor  with  LCD  digital 
operator keys (Run Fwd, Run Rev and Stop/Reset).  

 

READ 

It  transfers  inverter  parameters  to  the  LCD  digital  operator’s 
memory. (Refer to chapter 4 for more details.) 

 

WRITE 

It  copies  one  Parameter  Set  or  a  Parameter  Set  +  EzSQ 
(Drive  Programming)  saved  in  LCD  digital  operator  to  the 
inverter. (Refer to chapter 4 for more details.) 

 

ESC 

It returns to the above layer. 

 

SET 

It  jumps  to  the  below  layer  or  stores  the  change  introduced 
on the edit layer (after that it jumps to the above layer). 

 

UP 

It is used to move up the cursor, it increases a function code 
in 1 or increases a parameter value. 

 

DOWN 

It  is  used  to  move  down  the  cursor,  it  decreases  a  function 
code in 1 or it decreases a value. 

 

LEFT CURSOR 

It  is  used  to  move  the  cursor  to  the  left  or  it  moves  to 
previous mode when the display is at navigation level. 

 

RIGHT CURSOR 

It is used to move the cursor to the  right, or it moves  to the 
next mode when the display is at navigation level. 

10 

 

FWD RUN 

It  is  used  to  run  forward  the  motor  only  when  the  operation 
command (A002) is set in Digital operator. 
(Check KEY ENABLED LED) 

11 

 

REV RUN 

It  is  used  to  run  reverse  the  motor  only  when  the  operation 
command  (A002)  is  set  in Digital operator  
(Check KEY ENABLED LED) 

12 

 

STOP/RESET 

It  is  used  to  stop  the  motor  or  reset  an  alarm.  It  is  also 
possible  to  invalidate  the  STOP  key  by  B087  parameter.  
Besides it does  not response when LCD digital operator is 
reading or writing the parameters from/to the inverter. 

Summary of Contents for AX-OP05-E

Page 1: ...Cat No Ixxx Ex xx X DRAFT V0 90 LCD 5 LINE DIGITAL OPERATOR USER S MANUAL...

Page 2: ...of Option mode 11 3 4 Monitor A Display Mode 12 3 5 Monitor B Display Mode 13 3 6 Function Mode 14 3 7 Trip Mode 15 4 Read Write function and operation 16 4 1 R W Storage Mode Single READ function 16...

Page 3: ...erating this equipment Read the messages and follow these instructions carefully WARNING Indicates a potentially hazardous situation which if not avoided can result in serious injury or death CAUTION...

Page 4: ...emotely via a cable It has the additional capability of reading up to 5 Parameter Sets or a Parameter Set Drive Programming application from the inverter and store into the LCD digital operator memory...

Page 5: ...n operation function is effective by input terminal OPE Press the key more than 2 seconds 6 Key Enabled Led Green Light on only when operation command is set in LCD digital operator 7 LCD Display Plea...

Page 6: ...fter that it jumps to the above layer 6 UP It is used to move up the cursor it increases a function code in 1 or increases a parameter value 7 DOWN It is used to move down the cursor it decreases a fu...

Page 7: ...f LCD Display The first line of LCD monitor always displays the Display Mode the Motor Selected the Inverter RUN Status and the Display Selection Item Content of Display Content MONITOR A Monitor A mo...

Page 8: ...ew 5mm when you install the operator on the control panel Recommended torque is 0 9 1 0 Nm 80 18 40 26 5 2 M3x5 Backside 2 4 Recommended cable Model Content ICS 1 1m cable ICS 3 3m cable ICS 5 5m cabl...

Page 9: ...of each mode is shown as below Monitor Mode A The d group inverter parameters and F U group inverter parameter are displayed on the same screen in this mode The content of d group parameter is display...

Page 10: ...y to select the value to set Press the key to store the new value Press the key to cancel the new value And then 3 The cursor will appear in the second row 2 Date and Time 4 Pressing the key it enters...

Page 11: ...r to chapter 4 for more details 01 Single 02 Quad 02 Backlight Auto Off When LCD digital operator remains without key operations for 1 minute LCD backlight will be turned off When a key is pressed it...

Page 12: ...layed in the Monitor A pressing the key 2 After that use the or key to select the function code to be displayed into the Monitor A Use or key to move the cursor to the function code F001 in this case...

Page 13: ...cursor will appear on the first row of the four d group inverter parameters Use the or key to move between the four Monitor B inverter parameters 3 Pressing the key the cursor will appear on the funct...

Page 14: ...y at the navigation level 2 Pressing the key the cursor will appear in the function code Then use the or key to select the function that will be changed 3 After that pressing the key the cursor will a...

Page 15: ...he key the past trip information 6 trip errors and the warning information 1 time that are recorded on the inverter will be displayed Trip information is composed in two pages For change from page 1 P...

Page 16: ...d immediately after pressing or key After pressing the key in any display mode except Write mode and Option mode the inverter s parameter configuration are read and saved into LCD digital operator EzS...

Page 17: ...he inverter automatically after the parameter copy is finished It will return to the previous display after write function is completed When the inverter does NOT support EzSQ Drive Programming functi...

Page 18: ...am independently In this case LCD digital operator can save four sets of inverter parameters or one set of inverter parameters and one EzSQ Drive Programming program Please note that one EzSQ Drive Pr...

Page 19: ...fter pressing the key the Select data available are 01 Read data 02 Read data EzSQ 03 Verify data 04 Verify EzSQ 05 Cancel NOTE only three selection items 01 03 and 05 are displayed when memory No 2 N...

Page 20: ...90 Draft 4 4 R W Storage Mode Quad VERIFY function With and without EzSQ Drive Programming inverter support The result is shown automatically after the parameter or EzSQ Drive Programming verificatio...

Page 21: ...s Manual v0_90 110218 doc 21 Issue 0 90 Draft 4 5 R W Storage Mode Quad WRITE function When the inverter does NOT support EzSQ Drive Programming function Automatically it will return to previous disp...

Page 22: ...rsor up and down to select the data value to be written After pressing the key the Select data available are 01 Write data 02 Write data EzSQ 03 Cancel NOTE only 01 and 03 items are displayed when mem...

Page 23: ...ng parameter State and setting of the inverter Only parameter Parameter EzSQ Drive Programming Inverter is running EzSQ Drive Programming is running written unable Soft locked b031 Display is limited...

Page 24: ...ator 00 Full display 01 Function specific display 02 User setting 03 Data comparison display 04 Basic display 05 Monitor display b038 Initial screen selection Select the start display 000 Last modifie...

Page 25: ...is running Check if the WRITE key is pressed while soft lock is ON The WRITE key should be pressed only while the inverter stops Release the Soft Lock of the inverter INV in TRIP mode WRITE key is pr...

Page 26: ...wer supply or reset the terminal reset signal YES YES YES YES NO NO NO NO NO The inverter power supply is ON The cable is connected properly to both sides inverter and LCD digital operator The cable i...

Page 27: ...o 5 2 VDC Ambient temperature 10 to 50 degree C Humidity 20 to 90 RH no dew condensation Store temperature 20 to 65 degree C Place to use 1000m or less in height at a place with no corrosion gas and d...

Page 28: ...l operator is turned on Thus the time of Trip mode Read mode and Write mode cannot be displayed correctly unless the time is set properly in Option mode after power supply of LCD digital operator is t...

Reviews: