Installation

Mounting and Replacing the Pushbutton

Mounting Switch on a Panel

1. Mounting Direction for the 

Pushbutton and Switch

2. Removing the Pushbutton (Non-lighted Models Only)

• Insert the catches of the Pushbutton into the 

grooves of the Switch and push down on the 

Pushbutton until it is fixed securely to the 

Switch.

• With lighted models, the LED is built into the 

Switch and cannot be replaced.

• To remove the Pushbutton, hold both the 

Pushbutton and the Switch on the longer 

sides and pull the Pushbutton away from the 

Switch. 

(If the catches on the Pushbutton are bent 

outwards, it may result in malfunction.)

• When replacing the Pushbutton, if the cap is held 

on the sides with catches, internal components 

(e.g., plate) may come loose. Be sure to hold the 

Pushbutton by the sides without catches (i.e., the 

longer sides of the Switch) when removing.

Catches on the 
Pushbutton

Grooves in 
the Switch

LED terminals

Catch

1. Mount Leaf Spring

2. Mount Flange on Panel

3. Fit Flange with Switch

4. Removing Switch

• Press the leaf spring into the fitted 

groove on the upper surface of the 

Switch. For an easier fitting, first fit 

one side of the leaf spring, then 

press the other side into the fitting 

groove.

(It will be easier mounting the leaf 

spring of one side first, then mount 

the other side.)

• Insert the flange from the front 

surface of the panel.

• The flange has two opposing 

guides to facilitate its insertion into 

the panel cutout hole. Be sure the 

flange does not remain tilted with 

respect to the panel surface after 

being installed.

• While holding the flange, insert the 

opposing supports into the gaps 

between the leaf spring and 

Switch on the longer sides of the 

housing, and fit the rectangular 

hole of the flange with the 

projections of the switch housing.

• Insert a small flat-bladed screwdriver 

or tweezers into the flange support 

exposed on the rear of the panel. 

Pry up on each side to pull out the 

Switch.

Note: Be sure to fit the leaf spring 

exactly into the groove, and do 
not allow it to slip out of the 
groove.

Note: The mounting direction of the 

flange determines the orientation 
of the Switch.

Note: Completely remove any burrs on 

the panel cutout surface; 
otherwise, the flange and Switch 
will not attach solidly.

Note: Do not pry up the flange support 

more than necessary or the 
switch holding portions may be 
damaged.

Leaf spring

Leaf spring
fitting groove

Switch

Flange

Guide

Panel

Flange

Panel 
(t = 1 to 1.6 mm)

Cross Section

Support

Panel

Projection

Panel

Flat-bladed 
screwdriver
or tweezers

Summary of Contents for A3A Series

Page 1: ...omprises the Pushbutton LED lamp built in and Switch For information on combinations refer to Ordering Information A 3 A A 9 0 K 1 00E R 1 Shape of Pushbutton 2 Terminal 3 Switch Specifications Symbol Shape A Square T Round Symbol Type 0 Solder 1 PCB Symbol Operation Contact type A Momentary SPDT 3 A at 125 VAC 2 A at 30 VDC B Alternate K Momentary SPST NO 6 A at 125 VAC 2 A at 250 VAC 4 A at 30 V...

Page 2: ...e illumination A3AA 91L1 00E Round A3AT Solder Momentary Non lighted A3AT 90K1 00 LED surface illumination A3AT 90K1 00E Alternate Non lighted A3AT 90L1 00 LED surface illumination A3AT 90L1 00E PCB Momentary Non lighted A3AT 91K1 00 LED surface illumination A3AT 91K1 00E Alternate Non lighted A3AT 91L1 00 LED surface illumination A3AT 91L1 00E Appearance Terminal Operation Illumination Model Colo...

Page 3: ... 2 1 Maximum value V 3 0 Forward current IF Maximum value mA 20 20 25 Permissible loss PD Maximum value mW 60 60 75 Reverse voltage VR Maximum value V 3 Operating force OF max 2 45 N Release force RF min 0 15 N Total travel TT Approx 2mm Pretravel PT max 1 5 mm Locktravel alternate LTA min 0 5 mm Operating frequency Mechanical Momentary action 120 operations minute max Alternate action 60 operatio...

Page 4: ...erminals order them from your OMRON representative Refer to page 2 Pushbutton 1 Shape Square A3AA Switch 3 Ratings Standard load 1a 6 A at 125 VAC 2 A at 250 VAC 4 A at 30 VDC Standard load 1c 3 A at 125 VAC 2 A at 30 VDC Minimum applicable load 1 mA at 5 VDC resistive load 2 Terminals Solder terminal PCB terminal Round A3AT Diffusion sheet milky white 4 Color cap 5 Color Non lighted Model Red yel...

Page 5: ...sions 12 7 15 2 8 9 dia Round push button Two t0 4 terminals 8 9 Square push button 1 7 18 12 5 3 5 1 1 7 3 5 12 5 1 18 Three t0 4 terminals Non lighted Model Square Pushbutton Round Pushbutton SPST NO SPDT 12 7 15 2 8 9 dia Round push button Two t0 4 terminals 8 9 Square push button 1 7 18 12 5 3 5 1 Two t0 3 LED terminals 1 7 3 5 12 5 1 18 Three t0 4 terminals Two t0 3 LED terminals LED Surface ...

Page 6: ...with an illuminating push button Switch terminal t0 4 Terminal Arrangement BOTTOM VIEW Switch terminal t0 4 Lamp terminal t0 3 Non lighted Models PCB Dimensions BOTTOM VIEW LED Surface Illumination Models 0 5 0 8 2 0 5 0 8 2 0 8 1 7 1 3 5 0 8 1 7 1 3 5 1 95 5 7 10 16 LED terminal L NC NO C L Non lighted Models Terminal Hole Dimensions Switch terminal t0 4 LED Surface Illumination Models Switch ter...

Page 7: ... A3A 24 Flange Round A3A 25 Square Pushbutton For Side by side Mounting Panel Mounting Dimensions Round Pushbutton 11 5 dia 11 5 dia 11 5 dia 0 2 0 Square pushbutton Round pushbutton Horizontal multiple mounting Vertical multiple mounting 11 5 0 2 0 15 3 min 3 8 min 11 5 0 2 0 11 5 0 2 0 0 3 0 12 7 n 1 11 5 15 3 min 0 2 0 12 7 min 0 2 0 14 5 max 1 Flange Panel Leaf spring Recommended panel thickne...

Page 8: ... to the polarity An A3A with a built in LED does not have a limiting resistor Connect a limiting resistor The resistance can be calculated by using the following expression Note Make sure that the limiting resistor connected to the built in LED of an A3A satisfies the characteristics of the built in LED The mean forward current of the built in LED must be 8 mA minimum Example Conditions Red LED wi...

Page 9: ... the leaf spring then press the other side into the fitting groove It will be easier mounting the leaf spring of one side first then mount the other side Insert the flange from the front surface of the panel The flange has two opposing guides to facilitate its insertion into the panel cutout hole Be sure the flange does not remain tilted with respect to the panel surface after being installed Whil...

Page 10: ...1 07 0322 0207 Americas Europe https components omron com us en https components omron com eu en Asia Pacific China https components omron com sg en https components omron com cn Korea Japan https components omron com kr en https components omron com jp ja In the interest of product improvement specifications are subject to change without notice OMRON Corporation 2007 2022 All Rights Reserved ...

Reviews: