User Manual

S5700-24F-8G-4TF

24 Port 10G Core Network Switch

Summary of Contents for S5700-24F-8G-4TF

Page 1: ...User Manual S5700 24F 8G 4TF 24 Port 10G Core Network Switch ...

Page 2: ...ters Chapter 1 product introduction Describe the basic functional characteristics of the switch detailed hardware and software specifications and appearance information Chapter 2 hardware connectivity Instruct the connection between switch and other equipment and matters needing attention Chapter 3 product installation Instruct switch hardware installation method and matters needing attention Chap...

Page 3: ...o achieve maximum return on investment S5700 24f 8g 4tf switches with gigabit Ethernet RJ45 and SFP ports 10G SFP ports advanced security features and advanced quality of service QoS can be used as core distribution or access layer switches with high end port density switch stack and easy management is an ideal choice for all kinds of commercial network applications 1 2 product features Full gigab...

Page 4: ...ove the speed of network data processing Support stacked function Support physical stack of 9 switches virtual stack of 32 switches support ring Daisy chain stack link Support Apollo cloud platform one stop management Support the cloud platform to visually manage the resources of switches and PD devices making operation and maintenance management simpler ...

Page 5: ...hip Flash 16MB storag e 256MB DDR port 8 10 100 1000Mbps RJ45 ports Combo 4 10G SFP ports 24 Gigabit SFP ports 1 RJ45 Console port 1 10 100 1000Mbps management RJ45 port 1 USB 2 0 1 Mini usb Console port perfor mance Forward mode store and forward Back width 128Gbps Rate 96Mpps Support 16K MAC Thund 6KV ...

Page 6: ... Size L W H 440mm 320mm 44mm software feature Route Support RIP V1 V2 OSPFv1 OSPFv2dynamic routing Support static route DH CP Support DHCP Service Support DHCP Relay Support DHCP Snooping VLAN Support 4K VLAN Support 802 1Q VLAN MAC VLAN IP VLAN Voice VLAN ...

Page 7: ...tection Support user access restrictions based on port number IP address MAC address Support HTTPS SSL V3 TLS V1 SSH V1 V2 Support IP MAC PORT 3 in one Support ARP protect IP protect DoS protect Support DHCP Snooping DHCP attack protect Support 802 1X AC AAA Support port security and port isolation Support CPU protect function Support L2 Layer 2 L4 Layer 4 Packet ...

Page 8: ...port SP WRR WFQ priority scheduling algorithm Support automatic identification management and acquisition of information Tree Support STP IEEE 802 1d RSTP IEEE 802 1w and MSTP IEEE 802 1s standard Support loop protection root bridge protection TC protection BPDU protection BPDU filtering Multic Support IGMP v1 v2 Snooping Support for quick exit mechanism Support Multicast VLAN ...

Page 9: ...port Unknown unicast control Link togeth er Support static aggregation Support dynamic convergence Support IP MAC mixed load balancing mode Maximum support is 32 aggregation groups IPv6 Support IPv6 Ping IPv6 Tracert IPv6 Telnet Support IPv6 SSH IPv6 SSL Support WEB Management HTTP HTTPS SSL V3 Support CLI Telnet SSH V1 V2 Local port Support SNMP V1 V2 V3 ...

Page 10: ...protect DoS protect Support Apollo Support CPU monitoring Storage monitoring Support system log grading warning Support Ping Tracert test line test 1 4 Product appearance The front panel Contains indicator light RJ45 port SFP port CONSOLE port USB port as shown below ...

Page 11: ... on Power normal off Power out power switch not open power abnormal LINK AC T Device connect light green flicker The corresponding RJ45 port is connected off The corresponding RJ45 port is unconnected SYS System light green flicker System working normal off System working ...

Page 12: ...F 8G 4TF support 8 10 100 1000mbps adaptive RJ45 Combo port 1 RJ45 Console port 1 gigabit RJ45 management port SFP port The S5700 24F 8G 4TF provides 4 10G SFP uplink port and 24 gigabit SFP ports which can be inserted into gigabit SFP modules RST button When the switch is powered on press the button with a needle and release the device to enter the restart state ...

Page 13: ...the reset state When SYS lights up and the device is reset successfully The Console port Console port is used to connect to serial ports on computers or other terminals to manage or configure switches Rear panel Includes power socket power switch grounding terminal Power socket Connect the power cord to the switch S5700 24F 8G 4TF ...

Page 14: ...terminal Please ground the wire in case of lighting strike To avoid lightning strike and extend the service life of products Chapter 2 hardware connection 2 1 Connect the RJ45 port Connect the network cable to the RJ45 port of the switch and the opposite network device ...

Page 15: ...thly along the SFP port slot of the switch until the fiber module is in close contact with the switch 2 Confirm the Rx and Tx ports of the fiber module when connecting insert one end of the fiber into the Rx and Tx ports ensure that the Tx and Rx ends of the interface are correctly connected and the other end of the fiber is connected to another device 3 After power on check the status of the corr...

Page 16: ...e cleanliness of the fiber end face Please do not look directly into the fiber optic connector with your eyes as this may cause eye damage 2 3 Check before power on Check that the power supply of the power outlet meets the switch specifications Check that the power supply switch and rack are properly grounded Check whether the switch is connected to other network devices 2 4 device initialization ...

Page 17: ...m runs normally 2 The indicator of each port indicates the connection status of each port indicating that the switch has started to work normally Chapter 3 product installation 3 1 Installation Precautions Note To avoid damage to the equipment and personal injury caused by improper use please observe the following precautions safety precautions power supply remains off during the installation proc...

Page 18: ...ration of the switch and cause unnecessary damage To avoid the risk of electric shock do not open the case while the switch is working even if it is not charged do not open it yourself Before cleaning the switch first pull out the power plug of the switch Do not wipe with a moist fabric Do not use liquid to clean humidity In order to ensure long term stable operation of the switch and prolong its ...

Page 19: ...ipment The normal operation and storage temperature humidity of this series of switches are as follows Environmenta l description temperat ure Relative humidity working environment 0 C 40 C 10 to 90 RH does not condense Storage environment 40 C 70 C 5 to 90 RH does not condense elevation Products with this mark are only suitable for safe use in areas below 2000m above sea level ...

Page 20: ... operation of the device please pay attention to the following 1 Regular dust removal to keep indoor air clean 2 Make sure that the equipment is well grounded to ensure the smooth transfer of static electricity interference Electromagnetic interference will affect the electronic components such as capacitors and inductors inside the device by means of capacitive coupling inductive coupling impedan...

Page 21: ...ius and an instantaneous large current is enough to cause fatal damage to the electronic device For better lightning protection please note the following 1 Confirm that the rack is in good contact with the ground 2 Make sure the power outlet is in good contact with the ground 3 Reasonable wiring to avoid internal induction lightning 4 When using outdoor wiring it is recommended to use a signal lig...

Page 22: ...reparation The Phillips screwdriver electrostatic wrist strap and cable fiber may be used during installation 3 2 The product installation 19 standard rack mounting The s570 12G 12F is designed in accordance with the standard 19 inch rack size and can be easily installed on the rack The specific installation steps are as follows 1 Check the grounding and stability of the rack 2 Install the two L s...

Page 23: ...rounding of the rack is an important guarantee for anti static anti leakage lightning protection and anti interference of the equipment Therefore ensure that the grounding wire of the rack is properly installed The equipment installed in the rack is generally from bottom to top to avoid overload installation Avoid placing other heavy objects on the surface of the switch to avoid accidents Ensure h...

Page 24: ...Step1 Connect the network cable connected to the computer to the RJ45 port of the switch when the equipment is working normally Step2 manually change the computer IP address to 192 168 254 X X is 2 254 and the subnet mask 255 255 255 0 ...

Page 25: ...wser enter 192 168 254 1 in the address box and hit enter Step4 Enter the Web administrator login interface of the switch enter the default username and password admin in the input fields of username and password and then click login ...

Page 26: ...e web administration interface of the switch and are ready to start configuring the switch Chapter 4 packing list and usage suggestion 4 1 Open the package and check the following list carefully items quantity instruction switch 1 ...

Page 27: ...pay attention to the danger of strong power and safety protection 3 Please select the right power adapter to power the switch and confirm whether it conforms to the requirements of the switch before use 4 Do not use the switch in a humid environment to avoid water entering the fuselage through the shell and causing damage to the machine 5 Please start the power after the circuit connection is comp...

Page 28: ...n places with dust and electromagnetic radiation and do not use the switch in places with high temperature and no ventilation 8 Please do not place heavy objects on the switch to avoid accidents 9 It is recommended to use switches indoors and waterproof water tanks outdoors Note the pictures in the instruction manual are for reference only ...