DG-GS4900SE Series

Installation Manual

V1.0

20/11/2016

As our products undergo continuous development the specifications are subject to change

without prior notice

Содержание DG-GS4900SE Series

Страница 1: ...DG GS4900SE Series Installation Manual V1 0 20 11 2016 As our products undergo continuous development the specifications are subject to change without prior notice ...

Страница 2: ...l 10 1 4 3 Status LEDs 10 1 4 4 Interface Description of Front Panel 11 2 1 INSTALLATION NOTICE 13 2 1 1 Environmental Requirements 13 2 1 2 Installation Notice 17 2 1 3 Classs A Statement 17 2 1 4 Security Warnings 17 2 2 INSTALLATION PREPARATION 18 2 2 1 Verify the Package Contents 18 2 2 2 Required Tools and Utilities 18 2 3 INSTALLATION GUIDE 19 2 3 1 Installing Switch 19 2 3 2 Connecting Cons...

Страница 3: ...DG GS4900SE Series Installation Guide 3 2 3 4 SFP extended module Installation 21 2 3 5 Copper Cable Fiber Cable Connection 21 2 3 6 AC Power Supply Connection 22 ...

Страница 4: ...er ports 4Combo ports 4 10Gb optical ports DG GS4952SE 48 ports 10 100 1000BaseT 4 x 10GE SFP DG GS4928HPSE2 20 copper ports PoE 4Combo ports 4 10Gb optical ports DG GS4952HPSE 48 ports 10 100 1000BaseT PoE 4 x 10GE SFP DG GS4928FSE 24 Port Switch 1000Mbps SFP 16 Giga Combo 1 2 Introduction to Product 1 2 1 Product Overview DG GS4900SE series switches include DG GS4928SE DG GS4952SE and DG GS4928H...

Страница 5: ...G GS4900SE series switches support 802 1d w s 802 1Q 802 1p 802 3ad 802 3x GVRP DHCP and SNTP etc The switches also support the multicast protocols such as IGMP DVMRP and PIM Moreover DG GS4900SE series switches support RIPv1 2 OSPF BGP and IPv6 protocols All these protocols supported enable DG GS4900SE series switches to meet the requirements of complex network constructions ACL DG GS4900SE serie...

Страница 6: ...port SNMP In band and Out of band Management CLI and WEB interface and RMON It can mail the correlative sensitive information to the administrator abide by SMTP protocol DG GS4900SE series support SSH protocol ensure the configuration management security of the switch Flexible Power Ensure System DG GS4900SE series support two AC power which have the backup function if one of them is fault The pow...

Страница 7: ... 44 440 350 44 Weight 6kg 6kg Fixed ports 20 100 1000Base TX auto negotiation ethernet ports 4 1000Mb Combo ports 4 10Gb optical ports 20 100 1000Base TX auto negotiation ethernet ports 4 1000Mb Combo ports 4 10Gb optical ports Management ports 1 Console port 1 network management port which supports 1000Mb rate System power DG GS4900SE series support AC power input AC input The rating voltage rang...

Страница 8: ...hernet ports 4 10Gb optical ports Management ports 1 Console port 1 network management port which supports 1000Mb rate System power DG GS4900SE series support AC power input AC input The rating voltage range 100V 240V AC 50 60HZ The max voltage range 90V 264V AC 47HZ 63HZ Output power supply of PoE Do not support Support The max Power Consumption 50W 920W Fan None Support automatic timing Operatin...

Страница 9: ...hternet ports 4 1000Mb Combo ports 4 10Gb optical ports 5 function LEDs 1 network management port 1 alarm port 1 USB interface 1 mode button and 1 Console port Fig 1 2 Front Panel of DG GS4928HPSE2 DG GS4952SE Ethernet switches provide 48 100 1000Base TXauto negotiation ehternet ports 4 10Gb optical ports 1 network management port 1 alarm port 1 USB interface 1 mode button and 1 Console port Fig 1...

Страница 10: ...screw hole 1 fan and two power plug in interfaces Fig 1 4Back Panel of DG GS4928HPSE2 Fig 1 5 Back Panel of DG GS4952SE 52HPSE 1 4 3 Status LEDs LEDs of DG GS4900SE show the corresponding state Main board LEDs include two parts one is 24 1000M interface LEDs including 4 combo ports 4 SFP combo optical port interface LEDs and 4 SFP interface LEDs They show each port state at RJ45 plug in each port ...

Страница 11: ...bol Status Description PWR1 On Green Power1 is operating normally Off Power1 is not operating DIAG On Green blink System is loading On Green System is operating normally PWR2 On Green Power2 is operating normally Off Power2 is not operating MODE On Green The mode is changed to be default mode Off The system mode is the default mode FAN DG GS492 8HPSE2 52 HPSE supports On The fan is working normall...

Страница 12: ...1000Mbps auto negotiation MDI MDI X cable mode auto negotiation 5 kinds of UTP 100 m SFP SFP LR transceiver 10GBase LR SFP 1310nm SMF 10km SFP SR transceiver 10GBase SR SFP 850nm 62 5μm MMF 32m 50μm 500MHz km MMF 85m 50μm 2000MHz km MMF 300m SFP GT SFP GT Module 1000Base T SFP interface cardmodule RJ 45 interface ...

Страница 13: ...4V 50Hz DC power 40 60V The RPS input of the switch must be in the range of 11 5 13VDC The switch must be well grounded in order to avoid ESD damage and physical injury of people The switch should avoid the sunlight perpendicular incidence Keep the switch away from heat sources and strong electromagnetic interference sources The switch must be mounted to a standard 19 rack or placed on a clean lev...

Страница 14: ...re and Humidity Although the switch is designed to use 4 fans the site should still maintain a desirable temperature and humidity High humidity conditions can cause electrical resistance degradation or even electric leakage degradation of mechanical properties and corrosion of internal components Extreme low relative humidity may cause the insulation spacer to contract making the fastening screw i...

Страница 15: ...uring an air conditioning system failure and normal operation conditions should be recovered within 5 hours 2 1 1 3 Power Supply Before powering on the power supply please check the power input to ensure proper grounding of the power supply system The input source for the switch should be reliable and secure a voltage adaptor can be used if necessary The building s circuit protection system should...

Страница 16: ...t or lightning protection devices Keep away from high power radio transmitters radar transmitters and high frequency strong circuit devices Provide electromagnetic shielding if necessary 2 1 1 6 Rack Configuration The dimensions of the DG GS4900SE series is designed to be mounted on a standard 19 rack please ensure good ventilation for the rack Every device in the rack will generate heat during op...

Страница 17: ...ell grounded Users should maintain the switch regularly to extend the lifespan of the switch 2 1 3 Classs A Statement Class A ITE is a category of all other ITE which satisfies the class A ITE limits but not the class B ITE limits The following warning shall be included in the instructions for use Warning This is class A product In a domestic environment this product may cause radio interference i...

Страница 18: ...Power supply arcing Power line breakage Imperfect earth Overload circuit and Electrical short circuit If electric shock fire electrical short circuit occurs please cut off the electricity supply and alarm rapidly Rescue the injured person in the contingency under inherently safe give the injured person proper first aid treatment according to the injury state and seek help from the Medical Emergenc...

Страница 19: ...ith screws provided in the accessory kit 2 Put the bracket mounted switch smoothly into a standard 19 rack Fasten the DG GS4900SE series to the rack with the screws provided Leave enough space around the switch for good air circulation Caution The brackets are used to fix the switch on the rack They can t serve as a bearing Please place a rack shelf under the switch Do not place anything on top of...

Страница 20: ... Connect the other side of the console cable to a character terminal PC 3 Power on the switch and the character terminal Configure the switch through the character terminal 2 3 3 SFP Transceiver Installation DG GS4900SE series provide multiple 1000Mb SFP transceiver slots The procedure for installing SFP transceiver is shown below Step 1 Put on a ESD wrist strap or antistatic gloves Step 2 Insert ...

Страница 21: ...p 2 Insert the SFP transceiver to the 10G optical port Do not put the SFP transceiver up side down Step 3 Push the SFP transceiver gently until the optical module is mixed with the optical port Note the SFP 10Gb fiber transceiver is hot swappable Caution Do not stare directly at the 2 fiber bores in the fiber transceiver when the switch is in operation otherwise the laser may hurt your eyes 2 3 5 ...

Страница 22: ...t of the corresponding device and vice versa Step 3 Check the fiber port status indicator a lighted LED indicates that the link has been established otherwise the link is not ready and should be examined Caution Please verify the sign above the port to ensure using the other ports Connecting to wrong ports might damage the transceiver or the other ports When connecting other devices through a fibe...

Страница 23: ...ies is self adjustable for the input voltage As soon as the input voltage is in the range printed on the switch surface the switch can operate correctly 3 When the switch is powered on it executes self test procedure and startups Caution The input voltage must be within the required range otherwise the switch can be damaged or malfunction Do not open the switch shell without permission It can caus...