background image

 

Conductive Level Controller

 61F-GP-N2

1

Conductive Level Controller

61F-GP-N2

Automatic Water Supply and Drainage  
Control

• Ideal for level control of any conductive liquid.

• Compact plug-in controller for single- or two-point control of 

conductive liquid level.

• 24/110/120/220/230/240 VAC operation possible.

• Easy installation on DIN rail.

• Low voltage (AC) electrodes.

• Full surge protection.

2

2

220 VAC

220 VAC

Ordering Information

When placing your order, be sure to specify the desired operating voltage.

Accessories (Order Separately)

Selection Guide for Electrode Holders and Separators

Electrode Holders

Electrode Separators

Compact plug-in conductive level controller

61F-GP-N2

Example: 61F-GP-N2 120 VAC

Rated supply voltage

Applications

For city water and other 
general-use elec-
trodes. Easy-to-replace 
separate versions facili-
tate maintenance of 
electrodes.

When mounting space is 
limited. Special 3-pole 
holder of small size and 
light weight. Ideal for soft 
drink vendors, etc., where 
only limited space is avail-
able.

For low specific liquids. Used for sewage, 
sea water, etc., having a low specific resis-
tance. In sewage use, electrode holders 
must be installed 10 to 20 cm apart from 
one another. For acids, alkalis and sea wa-
ter, electrode holders may be as much as 
1 meter apart to operate properly.

When resistance to high 
pressure is required. Ide-
al for use in tanks where 
temperature or pressure 
inside the tank is high, 
e.g. 250

•

C

Mounting style

Flange

Screw

Flange

Screw

Insulator material

Phenol resin

Phenol resin

Ceramics

Teflon

Max. temperature

70

•

C (without water drips 

or vapour on the surface of 
the electrode holder)

150

•

C (without water drips or vapour on 

the surface of the electrode holder)

250

•

C (without water 

drips or vapour on the 
surface of the electrode 
holder)

No. of elec-
trodes

1

---

---

BF-1

BS-1

3

PS-3S

PS-31

---

---

No. of electrodes

Model

1

F03-14-1P

3

F03-14-3P

Summary of Contents for 61F-GP-N2

Page 1: ...maintenance of electrodes When mounting space is limited Special 3 pole holder of small size and light weight Ideal for soft drink vendors etc where only limited space is avail able For low specific l...

Page 2: ...industrial water sewage SUS 304 AISI 304 F03 01 SUS304 1 line F03 02 SUS304 F03 03 SUS304 Purified city water industrial water sewage dilute alka line solution SUS316 AISI 316 F03 01 SUS316 2 lines F...

Page 3: ...between these probes and the earth probe or tank if it is electrically conductive The water provides a current between the earth probe and the high level probe The output relay in the controller is en...

Page 4: ...hree integral 300 mm length electrodes However a type having 1 000 mm length electrodes is available on request Mounting Holes Rubber packing 11 3 l 7 12 32 38 5 PF1 2 Parallel thread Electrode SUS304...

Page 5: ...ds although they may corrode depending upon the temperature and working conditions Note that the Conductive Level Controller 61F GP N2 is capable of controlling liquids with specific resistances of up...

Page 6: ...nance of the product When fitting crimping terminal s to terminal screw s use a tight ening torque of between 0 45 and 0 6 N m Use power supply of appropriate specifications to provide control source...

Page 7: ...r application or use The following are some examples of applications for which particular attention must be given This is not intended to be an exhaustive list of all possible uses of the products nor...

Page 8: ...rs into inches multiply by 0 03937 To convert grams into ounces multiply by 0 03527 OMRON Corporation Industrial Automation Company Industrial Devices and Components Division H Q Measuring Components...

Reviews: