background image

3G3MX2-A

…

-V1

Multi-function Compact Inverter

NT328XC

Cat.No.

Manual Name

INSTRUCTION MANUAL

Thank you for purchasing 3G3MX2 series type V1 Inverter.
To ensure the safe operation, please be sure to read the safety 
precautions provided in this document along with all of the user 
manuals for the inverter. Please be sure you are using the most 
recent versions of the user manuals. Keep this instruction manual 
and all of the manuals in a safe location and be sure that they are 
readily available to the final user of the products.

OMRON Corporation

©OMRON Corporation 2012 All Rights Reserved.

3G3MX2 series type V1
 User’ s Manual

I585-E1

„

Indications and Meanings of Safety Information

Safety Precautions

In this user’s Manual, the following precautions and signal words 
are used to provide information to ensure the safe use of the 
3G3MX2 Multi-function Compact Inverter.
The information provided here is vital to safety. Strictly observe 
the precautions provided.

„

Meanings of Signal Words

WARNING

Indicates a potentially hazardous situation which,
if not avoided, may result in minor or moderate 
injury or in property damage. 

CAUTION

Indicates a potentially hazardous situation which, 
if not avoided, will result in minor or moderate injury,
or may result in serious injury or death. Additionally 
there may be significant property damage.

„

Alert Symbols in this Document

Turn off the power supply and implement wiring correctly.
Not doing so may result in a serious injury due to an electric shock.

WARNING

Be sure to ground the unit. Not doing so may result in a serious injury 
due to an electric shock or fire.
(200V class:type-D grounding, 400V class:type-C grounding)

Do not remove the front cover during the power supply and 10 minutes 
after the power shutoff. Doing so may result in a serious injury due to 
an electric shock.

Do not operate the Operator or switches with wet hands.
Doing so may result in a serious injury due to an electric shock.

Inspection of the Inverter must be conducted after the power supply has 
been turned off. Not doing so may result in a serious injury due to an 
electric shock.
The main power supply is not necessarily shut off even if the emergency 
shut off function is activated.

Do not change wiring and slide switches, put on or take off Operator 
and optional devices, replace cooling fans while the input power is being 
supplied. Doing so may result in a serious injury due to an electric shock.

Wiring work must be carried out only by qualified personnel. Not 
doing so may result in a serious injury due to an electric shock.

Do not touch the Inverter fins, braking resistors and the motor, which 
become too hot during the power supply and for some time after the 
power shutoff. Doing so may result in a burn.

CAUTION

The Inverter has high voltage parts inside which, if short-circuited, 
might cause damage to itself or other property. Place covers on the 
openings or take other precautions to make sure that no metal objects 
such as cutting bits or lead wire scraps go inside when installing and 
wiring.

Install a stop motion device to ensure safety. Not doing so might result 
in a minor injury. (A holding brake is not a stop motion device designed 
to ensure safety.)

Be sure to use a specified type of braking resistor / regenerative 
braking unit. In case of a braking resistor, install a thermal relay that 
monitors the temperature of the resistor. Not doing so might result in a 
moderate burn due to the heat generated in the braking resistor / 
regenerative braking unit. Configure a sequence that enables the 
Inverter power to turn off when unusual overheating is detected in the 
braking resistor / regenerative braking unit.

Do not connect resistors to the terminals (+1, P/+2, N/-) directly.
Doing so might result in a small-scale fire, heat generation or damage 
to the unit.

Do not dismantle, repair or modify the product.
Doing so may result in an injury.

Take safety precautions such as setting up a molded-case circut 
breaker(MCCB) that matches the Inverter capacity on the power 
supply side. Not doing so might result in damage to property due to 
the short circuit of the load.

Precautions for Safe Use

„

Installation and Storage

Do not store or use the product in the following places.

x

 Locations subject to direct sunlight.

x

 Locations subject to ambient temperature exceeding the specifications.

x

 Locations subject to relative humidity exceeding the specifications.

x

 Locations subject to condensation due to severe temperature fluctuations.

x

 Locations subject to corrosive or flammable gases.

x

 Locations subject to exposure to combustibles.

x

 Locations subject to dust (especially iron dust) or salts.

x

 Locations subject to exposure to water, oil, or chemicals.

x

 Locations subject to shock or vibration.

„

Transporting, Installation and Wiring

x

 Do not drop or apply a strong impact on the product.

Doing so may result in damaged parts or malfunction.

x

 Do not hold by the front cover and terminal cover, but hold by the fins 

during transportation.

x

 Confirm that the rated input voltage of the Inverter is the same as AC 

   power supply voltage.

x

 Do not connect an AC power supply voltage to the control input / output 

terminals. Doing so may result in damage to the product.

x

 Be sure to tighten the screws on the terminal block securely. Wiring work 

must be done after installing the unit body.

x

 Do not connect any load other than a three-phase inductive motor to the

U, V and W output terminals.

x

 Take sufficient shielding measures when using the product in the following 

locations. Not doing so may result in damage to the product.

Locations subject to static electricity or other forms of noise.
Locations subject to strong magnetic fields.
Locations close to power lines.

x

 If a parameter is set incorrectly when starting up, adjusting, maintaining, 

or replacing, an unexpected operation may occur. Perform the operation 
after enough confirmation.

x

 When using DriveProgramming, confirm that the program data is 

downloaded normally before starting operation.

„

Operation and Adjustment

x

 Be sure to confirm the permissible range of motors and machines before

operation because the inverter speed can be changed easily from low to 
high.

x

 Provide a separate holding brake if necessary.

x

 If the DriveProgramming stops during multi-function output, the output 

status is held. Take safety precautions such as stopping peripheral 
devices.

x

 Even if the inverter power supply is turned off, the counter-electromotive 

force occurs while the PM motor rotates, which may result in electric shock.
Do not remove the terminal block cover of the inverter until the PM motor 
stops.

x

 Be sure to confirm the RUN signal is turned off before resetting the alarm 

because the machine may abruptly start.

„

Maintenance and Inspection

x

 

Be sure to confirm safety before conducting maintenance, 
inspection or parts replacement.

x

 The capacitor service life is influenced by the ambient temperature.

Refer to "Product Life Curve" described in the User’ s manual. When a 
capacitor reaches the end of its service life and does not work as the 
product, you need to replace the capacitor.

x

 Mount the product vertically on a wall with the product’ s longer sides 

upright.
The material of the wall has to be nonflammable such as a metal plate.

Precautions for Correct Use

„

Installation

„

Restart Selection Function

x

 Do not come close to the machine when using the restart selection function

(b001, b008) because the machine may abruptly start when stopped by 
an alarm.

„

Deceleration Stop Function

x

 Do not come close to the machine when selecting reset in the deceleration 

stop function (b050) because the machine may abruptly start after the 
power is turned on.

„

Operation Stop Command

„

Motor Overload Protection

x

 Provide a separate emergency stop switch because the STOP Key on the 

Operator is valid only when function settings are performed.

x

 When checking a signal during the power supply and the voltage is 

erroneously applied to the control input terminals, the motor may start 
abruptly. Be sure to confirm safety before checking a signal.

„

Maintenance and Parts Replacement

x

 Inverters contain components and will operate properly only when each 

component operates normally. Some of the electrical components require 
maintenance depending on application conditions.
Periodic inspection and replacement are necessary to ensure proper 
long-term operation of Inverters. (Quoted from The Recommendation for 
Periodic Maintenance of a General-purpose Inverter published by JEMA.)

„

Product Disposal

x

 Comply with the local ordinance and regulations when disposing of the 

product.

UL Cautions

The warnings and instructions in this section summarizes the procedures 
necessary to ensure an inverter installation complies with Underwriters 
Laboratories guidelines.

x

 Use 60/75°C Cu wire only.

(For models:3G3MX2-A2001-V1, -A2002-V1, -A2004-V1, -A2007-V1, 
-AB015-V1, -AB022-V1, -A4004-V1, -A4007-V1, -A4015-V1, -A4022-V1, 
and -A4030-V1) 

x

 Use 75°C Cu wire only.

(For models:3G3MX2-AB001-V1, -AB002-V1, -AB004-V1, -AB007-V1, 
-A2015-V1, -A2022-V1, -A2037-V1, -A2055-V1, -A2075-V1, -A2110-V1, 
-A2150-V1, -A4040-V1, -A4055-V1, -A4075-V1, -A4110-V1 and 
-A4150-V1) 

x

 Suitable for use on a circuit capable of delivering not more than 100,000 

rms Symmetrical Amperes, 240 or 480 Volts Maximum.

x

 When Protected by CC, G, J, or R Class Fuses, or when Protected By A 

Circuit Breaker Having An Interrupting Rating Not Less Than 100,000 
rms Symmetrical Amperes, 240 or 480 Volts Maximum.

x

 Install device in pollution degree 2 environment. 

x

 Maximum surrounding air temperature rating of 50°C

x

 Solid State motor overload protection reacts with max. 150 % of FLA.

x

 Integral solid state short circuit protection does not provide branch circuit 

protection. Branch circuit protection must be provided in accordance with 
the National Electric Code and any additional local codes.

x

 Motor over temperature protection is not provided by the drive.

„

Fuse Size

The Inverter shall be connected with a UL Listed Cartridge Nonrenewable 
fuse, rated 600Vac with the current ratings as shown in the table below.

„

Terminal symbols and Screw size

Model No.

Screw
Size

Required
Torque(N·m)

Wire Range

AWG16(1.3mm

2

)

3G3MX2-AB001-V1, 3G3MX2-AB002-V1, 3G3MX2-AB004-V1

M3.5

1.0

3G3MX2-AB007-V1

M4

1.4

AWG12(3.3mm

2

)

3G3MX2-AB015-V1, 3G3MX2-AB022-V1

M4

1.4

AWG10(5.3mm

2

)

3G3MX2-A2001-V1, 3G3MX2-A2002-V1, 3G3MX2-A2004-V1, 
3G3MX2-A2007-V1

M3.5

1.0

AWG16(1.3mm

2

)

3G3MX2-A2015-V1

M4

1.4

AWG14(2.1mm

2

)

3G3MX2-A2022-V1

M4

1.4

AWG12(3.3mm

2

)

3G3MX2-A2037-V1

M4

1.4

AWG10(5.3mm

2

)

3G3MX2-A2055-V1, 3G3MX2-A2075-V1

M5

3.0

AWG6(13mm

2

)

3G3MX2-A2110-V1

M6

3.9 to 5.1

AWG4(21mm

2

)

3G3MX2-A2150-V1

M8

5.9 to 8.8

AWG2(34mm

2

)

3G3MX2-A4004-V1, 3G3MX2-A4007-V1, 3G3MX2-A4015-V1

M4

1.4

AWG16(1.3mm

2

)

3G3MX2-A4022-V1, 3G3MX2-A4030-V1

M4

1.4

AWG14(2.1mm

2

)

3G3MX2-A4040-V1

AWG12(3.3mm

2

)

M4

1.4

3G3MX2-A4055-V1, 3G3MX2-A4075-V1

AWG10(5.3mm

2

)

M5

3.0

3G3MX2-A4110-V1, 3G3MX2-A4150-V1

AWG6(13mm

2

)

M6

3.9 to 5.1

Class J

Class J

Class J

Model No.

Type

Rating

10A, AIC 200kA

3G3MX2-AB001-V1, 3G3MX2-AB002-V1, 
3G3MX2-AB004-V1

3G3MX2-AB007-V1
3G3MX2-AB015-V1

3G3MX2-A2001-V1, 3G3MX2-A2002-V1,
3G3MX2-A2004-V1
3G3MX2-A2007-V1, 3G3MX2-A2015-V1
3G3MX2-A2022-V1
3G3MX2-A2037-V1 
3G3MX2-A2055-V1, 3G3MX2-A2075-V1
3G3MX2-A2110-V1, 3G3MX2-A2150-V1
3G3MX2-A4004-V1, 3G3MX2-A4007-V1,
3G3MX2-A4015-V1, 3G3MX2-A4022-V1
3G3MX2-A4030-V1, 3G3MX2-A4040-V1
3G3MX2-A4055-V1, 3G3MX2-A4075-V1
3G3MX2-A4110-V1, 3G3MX2-A4150-V1

20A, AIC 200kA

3G3MX2-AB022-V1

30A, AIC 200kA
30A, AIC 200kA

10A, AIC 200kA

15A, AIC 200kA
20A, AIC 200kA
30A, AIC 200kA
60A, AIC 200kA
80A, AIC 200kA

10A, AIC 200kA

15A, AIC 200kA
30A, AIC 200kA
50A, AIC 200kA

Conformance to EU Directives

x

 It is necessary to use optional EMC filter to comply with EMC directive 

(EN61800-3).

x

 For earthing, selection of cable, and any other conditions for EMC 

compliance, please refer to the User’ s manual for installation.

„

OMRON Corporation

Shiokoji Horikawa, Shimogyo-ku, Kyoto, 600-8530, Japan

„

Omron Europe B.V.

Wegalaan 67-69, NL-2132 JD Hoofddorp, The Netherlands

2272253-5D

x

 For the motor overload protection, be sure to set the rated current of your 

motor to the Electronic Thermal Level (b012/b212) and PM Motor Rated 
Current (H105). 

AVERTISSEMENT: ne retirez pas le capot avant pendant l’alimentation 
et 10 minutes après l’arrêt de l’alimentation. Cela peut entraîner de 
grave blessure due à un choc électrique.

Safety

For use of the drive as a safety device, to meet the requirements of the 
ISO13849-1, please refer to user’s manual.

For KC Marking Only

஛ἽGὤὤ

ஂ㛹ⱨ㟝Gⵝ㋕䋩㐔ὤ㣄㣠ஃ

G

㢨Gὤὤ⏈G㛹ⱨ㟝O஛ἽPG㤸㣄䑀㤵䚝ὤὤ⦐㉐G䑄⬘㣄G❄⏈G㇠㟝㣄⏈G㢨G
㥄㡸G㨰㢌䚌㐐ὤGⵈ⢰⮤SGᴴ㥉㞬㢌G㫴㜡㜄㉐G㇠㟝䚌⏈Gᶷ㡸G⯝㤵㡰⦐G
䚝⏼␘U

Reviews: