AIR COOLED CHILLERS
ELECTRICAL DATA
19
OALC
080
OALC
10
0
OALC
120
OALC
140
OALC
160
OALC
180
OALC
200
OALC
220
OALC
240
MODEL
No.
SUPPL
Y
VOL
TA
G
E
COMPRESSOR
TYPE-1
COMPRESSOR
TYPE-2
CONDENSER
FA
N
MOT
ORS
ELECTRICAL
DA
TA
CRANKCASE
HEA
TER
Total
W
atts
V
olts
Total
Amps
Qty
.
(each)
Fuse
Size
FCA
HP
(each)
FLA
(each)
Qty
.
(3
ph.)
CB
Poles
CB
MT
A
Qty
.
LRA
(each)
RLA
(each)
Qty
.
MOCP
MCA
Max.
Min.
Nominal
(V-Ph-Hz)
208/230-3-60
380-3-60
460-3-60
380/415-3-50
208/230-3-60
380-3-60
460-3-60
380/415-3-50
208/230-3-60
380-3-60
460-3-60
380/415-3-50
208/230-3-60
380-3-60
460-3-60
380/415-3-50
208/230-3-60
380-3-60
460-3-60
380/415-3-50
208/230-3-60
380-3-60
460-3-60
380/415-3-50
208/230-3-60
380-3-60
460-3-60
380/415-3-50
208/230-3-60
380-3-60
460-3-60
380/415-3-50
208/230-3-60
380-3-60
460-3-60
380/415-3-50
187
342
414
342
187
342
414
342
187
342
414
342
187
342
414
342
187
342
414
342
187
342
414
342
187
342
414
342
187
342
414
342
187
342
414
342
253
418
506
457
253
418
506
457
253
418
506
457
253
418
506
457
253
418
506
457
253
418
506
457
253
418
506
457
253
418
506
457
253
418
506
457
454
275.9
227
230.2
544
325.4
272
275.2
694.8
381.6
319.3
322.5
723
440.4
361.5
366.3
852
518.1
426
431.6
945.2
527.2
472.6
479.6
1032
617
516
522.4
1
182.8
673.2
563.3
569.7
1326.8
728.6
610.3
617.5
600
350
300
300
700
450
350
350
1000
500
450
450
800
500
400
400
1000
600
500
500
1000
600
500
500
1200
700
600
600
1200
800
600
700
1600
800
700
700
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
2
2
2
2
-
-
-
-
2
2
2
2
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
180
90
90
90
-
-
-
-
224
135
11
2
11
2
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
1070
535
535
535
-
-
-
-
1070
601
535
535
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
3
3
3
3
-
-
-
-
3
3
3
3
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
150
80
70
80
-
-
-
-
175
125
90
90
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
4
4
4
4
-
-
-
-
4
4
4
4
-
-
-
-
8
8
8
8
8
8
8
8
8
8
8
8
12
12
12
12
14
14
14
14
14
14
14
14
16
16
16
16
16
16
16
16
18
18
18
18
5
2.7
2.5
2.9
5
2.7
2.5
2.9
5
2.7
2.5
2.9
5
2.7
2.5
2.9
5
2.7
2.5
2.9
5.8
3.1
2.9
3.4
5
2.7
2.5
2.9
5
2.7
2.5
2.9
5
2.7
2.5
2.9
1.5
1.5
1.5
1.5
1.5
1.5
1.5
1.5
1.5
1.5
1.5
1.5
1.5
1.5
1.5
1.5
1.5
1.5
1.5
1.5
1.7
1.7
1.7
1.7
1.5
1.5
1.5
1.5
1.5
1.5
1.5
1.5
1.5
1.5
1.5
1.5
40
21.6
20
23.2
40
21.6
20
23.2
40
21.6
20
23.2
60
32.4
30
34.8
70
37.8
35
40.6
81.2
43.4
40.6
47.6
80
43.2
40
46.4
80
43.2
40
46.4
90
48.6
45
52.2
30/20
30/10
30/9
30/12
30/20
30/10
30/9
30/12
30/20
30/10
30/9
30/12
30
30
30
30
30/20
30/10
30/9
30/12
30/20
30/25
30/10
30/25
30/20
30/10
30/9
30/12
30/20
30/10
30/9
30/12
30
30
30
30
6/3
3/3
3/3
3/3
6/3
3/3
3/3
3/3
6/3
3/3
3/3
3/3
12
6
6
6
12/3
6/3
6/3
6/3
12/3
6/3
6/3
6/3
12/6
6/6
6/6
6/6
12/6
6/6
6/6
6/6
18
9
9
9
11
5
11
5
11
5
11
5
11
5
11
5
11
5
11
5
11
5
11
5
11
5
11
5
11
5
11
5
11
5
11
5
11
5
11
5
11
5
11
5
11
5
11
5
11
5
11
5
11
5
11
5
11
5
11
5
11
5
11
5
11
5
11
5
11
5
11
5
11
5
11
5
280
280
280
280
400
400
400
400
400
400
400
400
560
560
560
560
560
560
560
560
800
800
800
800
800
800
800
800
800
800
800
800
800
800
800
800
2.43
2.43
2.43
2.43
3.48
3.48
3.48
3.48
3.48
3.48
3.48
3.48
4.87
4.87
4.87
4.87
4.87
4.87
4.87
4.87
6.96
6.96
6.96
6.96
6.96
6.96
6.96
6.96
6.96
6.96
6.96
6.96
6.96
6.96
6.96
6.96
NOTES
1.
Main
power
must
be
supplied
from
a
single
field
supplied
and
mounted
fused
disconnects,
using
dual
element
time
delay
fuse
or
circuit
breaker
.
2
.
The
maximum
incoming
wire
size
is
500
mcm.
On
units
having
MCA
greater
than
500
mcm
wire,
the
factory
supplied
power
termina
lblock
will
accept
two
parallel
field
wires
per
phase.
3.
The
compressor
crankcase
heaters
must
be
energized
for
12
hours
before
the
unit
is
initially
started
or
after
a
prolonged
pow
er
disconnection.
4.
Minimum
and
maximum
unit
supply
voltages
are
shown
in
the
tabulated
data
above.
5
.
Neutral
line
required
on
380V-3Ph-60Hz
&
380/415V-3Ph-50
Hz
power
supply
onl
y.
LEGEND:
MCA
-
Minimum
Circuit
Ampacity
MOCP
-
Maximum
Over
Current
Protection
RLA
-
Rated
Load
Amps
LRA
-
Locked
Rotor
Amps
CB
-
Circuit
Breaker
MT
A
-
Must
T
rip
Amps
FLA
-
Full
Load
Amps
HP
-
Horse
Power
FCA
-
Fan
Circuit
Amps
CB
Poles
CB
MT
A
Qty
.
LRA
(each)
RLA
(each)
Qty
.
2
2
2
2
2
2
2
2
2
2
2
2
4
4
4
4
4
4
4
4
2
2
2
2
4
4
4
4
2
2
2
2
4
4
4
4
184
11
3
92
92
224
135
11
2
11
2
291
160
133
133
156
96
78
78
184
11
3
92
92
224
135
11
2
11
2
224
135
11
2
11
2
291
160
133
133
291
160
133
133
808
497
404
404
1070
601
535
535
1
190
650
570
600
646
397
323
323
808
497
404
404
1070
601
535
535
1070
601
535
535
1
190
650
570
600
1
190
650
570
600
3
3
3
3
3
3
3
3
3
3
3
3
3
3
3
3
3
3
3
3
3
3
3
3
3
3
3
3
3
3
3
3
3
3
3
3
150
100
80
80
175
125
90
90
225
150
125
125
125
80
70
70
150
100
80
80
175
125
90
90
175
125
90
90
225
150
125
125
225
150
125
125
4
4
4
4
4
4
4
4
4
4
4
4
8
8
8
8
8
8
8
8
4
4
4
4
8
8
8
8
4
4
4
4
8
8
8
8