10
Insertion Length (
L
) as follows:
L = A + ½ wall thickness
3. Clean and lubricate exposed probe body using light machine oil or a grease to avoid damag-
ing o-ring seals.
4. Tighten the Hex cap on the Process Insertion Fitting. Move the Process Insertion Fitting up
the probe body until the exact distance calculated in Step 2 is reached. This distance
L
, will
be from the bottom of the probe body to the bottom of the Hex nut on the Process Insertion
Fitting. Make a mark on probe body at the top of the hex cap (Figure 4) using an indelible
marker.
5. Apply a lubricant to the probe body. Slide the
Process Insertion Fitting down the Probe Body
until it touches the safety stop and install in the
Insertion Tool Adapter.
6. Secure the Insertion Tool Adapter from turning
while tightening the Process Insertion Fitting,
(Figure 5).
Figure 6
Need new picture
L
Mark probe body
here
Figure 9
Marking Insertion Length on Probe
Figure 10
Tightening the process insertion fitting