5) VERIFY OPERATION
Once the module has been installed and configured per steps 1 and 2, verify the
module is operational by viewing the LED indicators.
The XG does not generate data, it only passes the data it receives from the
connected equipment. Both transceivers must be installed and connected in
order for the module to pass data traffic. P1/P2 Lk LED indicates an optical
connection has been established. It does not indicate the presence of data
traffic. Check the attached equipment for confirmation of data traffic.
Legend
OFF State
Color
ON/Blinking State
Pwr
Off – No power
Green
Green – Power On
P1/P2
Lk
Off – No Transceiver
detected or no fiber link
Green
Green Solid – Fiber link
Green Blinking (1/2Hz) – When SFD is enabled,
receiving remote fiber fault signal from link partner
P1/P2
Stat
Off – Transceiver does not
support digital diagnostic
or no transceiver installed
Green
Green Solid – Transceiver supports digital
diagnostic and no DDMI Alarm Detected
Amber
Amber Solid – Transceiver supports digital
diagnostic and DDMI alarm detected
P1 LB
Off – Port loopback mode
not enabled or configured
Green
Green Solid – Port set to Loopback mode and port
in loopback
Green Blinking (1 Hz) - Port responding to Circuit
Test activation with valid Circuit Test response
Green Blinking (5 Hz) - Port initiating Circuit Test
and receiving valid Circuit Test response
Amber
Amber Solid – Port set to loopback mode, but XFP
does not support loopback
Amber Blinking (5 Hz) - Port initiating Circuit Test
and not receiving valid Circuit Test response
P2 LB
Off – Port loopback mode
not enabled or configured
Green
Green Solid – Port set to Loopback mode and port
in loopback
Amber
Amber Solid – Port set to loopback mode, but XFP
does not support loopback
P1 Lk,
P1 Stat,
P2 Lk,
P2 Stat
-
Amber
Simultaneous Amber Blinking (1Hz) – Ports disabled
due to unsupported power level of the installed
XFP transceiver. Module drawing more current than
allowed
LED Indicators
Page
SPECIFICATIONS
Description
iConverter
XG
Protocol-Transparent Media Converter/Transponder
Standard
Compliances
IEEE 802.3ae (10G Ethernet),
SONET OC-192, SDH STM-64,
INCITS T11.2 (10G Fibre Channel),
ITU-T G.709 OTN,
CPRI option 6, 7, 7A and 8
Regulatory
Compliances
UL, CE, FCC Class A, NEBS 3 Compliant,
RoHS, WEEE, REACH, SFF-8077, SFF-8477
Frame Size
Unlimited
Port Types
Fiber:
Power Level 1 and 2 SFP+/XFP transceivers
Cable Types
Fiber:
Multimode: 50/125µm, 62.5/125µm
Single-mode: 9/125µm
AC Power
Requirements
AC Adapter:
100 - 120VAC/60Hz
(US)
0.20A @ 120VAC (max)
AC Adapter:
100 - 240VAC/50 - 60Hz
(Universal)
0.20A @ 120VAC (max)
DC Power
Requirements
DC Input:
8599x-00: 3.3VDC, 1.5A @ 3.3VDC (Max)
(Backplane)
8599x-01: 3.3VDC, 2.1A @ 3.3VDC (Max)
8599x-11: 3.3VDC, 2.5A @ 3.3VDC (Max)
DC Input:
7 - 60VDC
(Terminal Block)
1.2A @ 9VDC, 0.9A @ 12VDC
2-Pin Terminal (non-isolated)
DC Input:
7 - 60VDC
(AC Adapter)
1.2A @ 9VDC, 0.9A @ 12VDC
2-Pin Terminal (non-isolated)
Dimensions
W x D X H
Plug-in:
0.85” x 4.5” x 2.8” (21.6 mm x 114.3 mm x 71.1 mm)
Standalone:
3.1” x 4.8” x 1.0” (78.7 mm x 121.9 mm x 25.4 mm)
Standalone:
3.8” x 4.8” x 1.0” (96.5 mm x 121.9 mm x 25.4 mm)
(Wall-mount)
Weight
Plug-in:
8 oz.; 226.8 grams
Standalone:
1.0 lb.; 453.6 grams
Standalone:
1.5 lbs.; 680.4 grams
(w/Adapter)
Temperature
Commercial:
0 to 50°C
Storage:
-40 to 80°C
Humidity
5 to 95% (non-condensing)
Altitude
-100m to 4,000m
MTBF (hrs)
Plug-in:
770,000
Standalone:
918,000
US Adapter:
480,000
Universal Adapter: 480,000
Warranty
Lifetime warranty with registration and 24/7/365 free Technical Support
Page 12
040-8599P-001C 11/20