4. Set the flow interval in liters
If the tank has irregular shape, and/or there are wider or narrower parts, it is
recommended to perform calibration on such tanks with higher amounts of calibration
steps to improve accuracy.
5. Press the “Start/continue calibration” button
6. Fill with an amount of fuel equal to the flow interval
7. Press “Add line”
The “Liters” column will display the refueling volume equal to the predefined flow
interval.
The “Sensor” column will display the value equal to the refueling volume.
8. Press “Add line”
9. Repeat items 6, 7 and 8 according to the number of control points. Minimum
recommended number of control points: 20
10. Press the “Finish calibration” button
11. Save the calibration table in a calibration file (.ctb), Omnicomm Online (.xml) file, in
the Terminal or in the Indicator, by pressing the “Export” button
When performing the calibration table export to the Omnicomm Online (.xml) file, the
“Export” window will open. Specify the Omnicomm LLS sensor number to display in
Omnicomm Online.
17
Calibration