5. Install the fuse in the fuse holder
6. If necessary, seal the bolt (self-tapping screw) and the connection. Multiple
Omnicomm LLS 5 sensors must be connected side-by-side via the RS-485 interface.
Calibration
Calibration of the fuel tank is necessary to verify the conformity of the digital code issued
by the Omnicomm LLS 5 sensor to the fuel volume in a particular fuel tank.
Calibration of the fuel tank is performed by refueling up the tank – from empty to full,
with a certain refueling interval, and recording the Omnicomm LLS 5 sensor readings in
the cali-bration table.
A container may be calibrated by draining.
The calibration of a container with multiple Omnicomm LLS 5 sensors is performed simi-
larly to the calibration with one sensor. Before the calibration process, add the necessary
quantity of sensors and specify the network addresses.
The calibration is performed for all sensors simultaneously. Connecting multiple sen-sors
to a PC using a KTZ splitter.
Calibration of the tank with one Omnicomm LLS 5 sensor:
1. Empty the fuel tank
2. Connect the sensor to a PC according to the diagram in the Setting section
3. Run the Omnicomm Configurator program. Select “Calibration”.
Omnicomm Configurator (PC):
15
Calibration
Summary of Contents for LLS 5
Page 1: ...Omnicomm LLS 5 Fuel Level Sensor User Manual 02 10 2020...
Page 10: ...Omnicomm Configurator PC The fuel level value is displayed without filtering 10 Setting...
Page 23: ...23 Fuel Level Sensor Installation Recommendations for Cylindrical Fuel Tanks...
Page 26: ...info omnicomm world com www omnicomm world com...